JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022072923900Web · corrodedFORWARD CARGO THRESHOLD WEB HAS CORROSION STA-440 TO STA-492 (MARKED) / [01] THIS PART THICKNESS IS OUT OF LIMITS AFTER BLENDING TO REMOVE CORROSION.THICKNESS WAS AT .050 NOW AT .040. PER SRM 53-00-53-1A-2.;[02] THIS PART THICKNESS IS OUT OF LIMITS AFTER BLENDSDR SIMA20220629007Shear Tie · corrodedSSI 53-23-005 AFT GALLEY RH SHEER PANEL OTBD SPLICE IS CORRODED (MARKED) (LEVEL 2 CORROSION) -C/A-RAR AFT GALLEY RH SHEER PANEL OTBD SPLICE IAW EMB-175 SRM 51-40-08SDR SIMA20220629006Floor Splice · corrodedSSI 53-23-005 AFT GALLEY RH FLOOR SPLICE AT FR 90 IS CORRODED (MARKED) (LEVEL 2 CORROSION) -C/A-REMOVED AND INSTALLED SERVICEABLE AFT GALLEY RH FLOOR SPLICE AT FR 90 IAW EMB 175 SRM 51-40-08 AND 51-41-02SDR SIMA20220629005Floor Panel · corrodedSSI 53-23-005 AFT GALLEY CENTER SHEER PANEL IS CORRODED (MARKED)(MAJOR REPAIR)(LEVEL 2 CORROSION) -C/A-RAR AFT GALLEY CENTER SHEER PANEL IAW EMB-175 SRM 51-40-08SDR SIMA20220629004Panel Support · corrodedSSI 53-23-005 AFT GALLEY RH OTBD FLOOR PANEL SUPPORT AT FR 90 IS CORRODED. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH OUTBD FLOOR PANEL SUPPORT BTW FR 88 AND FR 90 IAW EMB 175 SRM 51-40-08.SDR SIMA20220629003Panel Support · corroded. SSI 53-23-005 AFT GALLEY RH SHEER PANEL IS CORRODED-C/A-REMOVED AND INSTALLED SERVICEABLE AFT GALLEY RH SHEER PANEL IAW EMB-175 SRM 51-40-08.SDR ASAA2022062939065Door Sill · corrodedMAIN CABIN R2 DOOR SILL BEAM CORROSION AT NUTPLATE GROUNDED - YES. REMOVED ALL CORROSION FOUND TO BE OUT OF LIMITS. .875" L X 1" W X .063" D IAW A320 SRM 53-41-14. CUTOUT DAMAGE AND PERFORMED REPAIR PRINCIPLE 5 CUTOUT DIMENSIONS 1" L X 1.2 " W IAW A320 SRM 53-SDR IPXA2022071284112Skin · dentedINSPECTION TYPE:SEG1RH FUSELAGE SKIN FROM STA 1540-1580, S-28R TO S-29R HAS DENT FOUND TO BE OUT OF LIMITSACCOMPLISHED REPAIR IAW SRM 53-00-01-2R-29, PER SRM 53-60-01-2RSDR IPXA2022070983976Panel · crackedINSPECTION TYPE:CPANEL 413BL HAS 1 EA CRACK UNDER SEAL I/B INTERIORACCOMPLISHED DOUBLER REPAIR PER SRM 54-52-21 FIG 204SDR R61A2022070700427Duct · debondedSTRANGE CONSTANT VIBRATION STARTING APPROXIMATELY 11,000 FEET. FELT LIKE HITTING RUMBLE STRIPS AT HIGHWAY SPEEDS. NO OTHER INDICATION. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. R&R DISBONDED RAM AIR INLET DUCTS.SDR IPXA2022062983619Crossbeam · bentINSPECTION TYPE:CMAIN DECK FR 49 RH CROSSBEAM P/N 538133780000 IS BENT.REMOVE AND REPLACE PER SRM 51-40-21.SDR IPXA2022062983617Crossbeam · bentINSPECTION TYPE:CMAIN DECK FR 50 RH CROSSBEAM P/N 538133780000 IS BENT.REMOVE AND REPLACE PER SRM 51-40-21.SDR JR2R20220629780Gusset · corrodedRBL 11 FR90 DOUBLER CORRODEDSDR JR2R20220629788None · corrodedLH MOP SILL CORRODED IN MULTIPLE AREASSDR JR2R20220629789None · corrodedRH MOP SILL CORRODED IN MULTIPLE AREASSDR JR2R20220629766Doubler · corrodedDOUBLER FWD OF R1 DOOR CORRODEDSDR EVCA0628221Rib · crackedTHERE IS AN APPROX 0.5 INCH CRACK ON RH RIB AT INBOARD OUTER EDGE.SDR EVCA062822Rib · crackedTHERE IS AN APPROX 0.50 INCH CRACK ON LH RIB AT INBOARD OUTER EDGE.SDR SWIA2022081666284Crossbeam · corrodedFS1051.00- CORROSION FOUND ON R/H FLOOR CROSSBEAM AT FLOOR BOARD FASTENER HOLE (MARKED IN RED INK) (C-CHECK RO 8/14/2022) REPAIRED RH FLOOR CROSSBEAM AT FS1051.00 REF MHIRJ REO 670-53-61-2083 REV -- DATED 2022-07-18 AND CRJ-700 SRM 51-42-06-001-001-A01.SDR IPXA2022080284838Longeron · corrodedINSPECTION TYPE:3CCENTER CARGO LONGERON HAS CORROSION BETWEEN STA. 1752 TO 1811.REPAIRED CORRODED LONGERON 47 R/H BETWEEN STA. 1611 TO 1811 IAW VT-SAA EA 011-5350-01-A9638 REV. I/R AND UPS EO MD11-5310-84327-A. (MAJOR) REF. FAA FORM 8100-9 BY JEFFREY TOM (AR-6SDR SWAA2022072523332Scuff Plate · brokenFWD CARGO BAY FWD CORNER SCUFF PLATE IS BROKEN / [01] WELDED BROKEN AREA OF FWD CARGO BAY FWD CORNER SCUFF PLATE USING ER4043 FILLER ROD LOT NUMBER 1131216 PER SRM 53-60-15-2R-1 PARA 4.B.(2) AND (4)<BR>EQUIPMENT USED; WELDING MACHINE E10583; CALIBRATION DUE DASDR SWAA2022072523333Scuff Plate · brokenFWD CARGO BAY AFT CORNER SCUFF PLATE IS BROKEN / [01] WELDED BROKEN SECTION OF FCB AFT CORNER SCUFF PLATE USING ER4043 FILLER ROD LOT NUMBER 1131216 PER SRM 53-30-15-2R-1 PARA 4.B. (2) AND (4)<BR>EQUIPMENT USED; WELDING MACHINE E10583; CALIBRATION DUE 12/2022;SDR V0XD20220714001Skin · damagedLH FUSELAGE SKIN AT FS565 AND STRINGER 17L HAS A PREVIOUS BLEND. CORRECTIVE ACTION: ACCOMPLISHED PERMANENT REPAIR TO THE LH FUSELAGE SKIN BY STRIPPING PAINT, PERFORMING UT AND UT INSPECTIONS AND RESTORING FINISH IAW OLIVER WYMAN CAVOK EA 22-C7-53-0443 REV A. NSDR ASAA2022062738947Angle · corrodedAFT CARGO COMPARTMENT FWD DOOR SHIELD SUPPORT ANGLE FS 767-787 RBL 20 CORRODED. GROUNDED - YES. REMOVED CORR, DETERMINED OUT OF LIMITS IAW B737-800 SRM 53-60-15-1A-1 REMOVED & REPLACED ANGLE IAW B737-800 SRM 51-40-02-0G-0 W = 1 O = .050 R = .010 L =1 D = .040.SDR AALA202207066616Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK FOUND ON PRESSURE DECK LOCATED AT STA 663 AND LEFT BUTT LINE 33. INSTALLED EXTERNAL DOUBLER REPAIR ON PRESSURE DECK PER ECO 5715J112.SDR ASAA2022062738884Baffle · corrodedAFT CARGO COMPARTMENT BAFFEL FS 747-767 RBL 20 CORRODED. GROUNDED - YES. UPON FURTHER INVESTIGATION FOUND CORROSION THRU BAFFEL (100% LOSS) FOUND TO BE OUT OF LIMIT IAW B737-800 SRM 53-00-53-1A-2, REMOVED AND REPLACED BAFFEL IAW B737-800 SRM 51-40-02-0G-0 PARASDR KCSA202206271082Torque Box · corrodedCORROSION IN AFT PIT ON UPPER SURFACE OF TORQUE BOX CLOSEOUT AT APPROX. STA 1280 LBL 20SDR CALA2022062701593None · corrodedCABIN FLOOR SUPPORT STRUCTURE BTW FR66-FR68, Y-1292, FLOOR BEAM WITH CORROSION,REMOVED CORROSION ON CABIN FLOOR BEAM FR68 Y-1292, MEASURED ORIGINAL THICKNESS .160 D=0.110" L=1.920" W=2.200" FOUND OUT OF LIMITS. FLOOR BEAM REMOVED AND REPLACED STA: ST ENG BFM.SDR SIMA20220626005Track · corrodedSSI 53-22-012 RH FLOOR SEAT TRACK GOUGED AND CORRODED AT FR 57. (LEVEL 2 CORROSION) -C/A-ACCOMPLISHED SPLICE DEVICE REPAIR TO RH FLOOR SEAT TRACK AT FR 57 IAW EMB 175 SRM 53-00-10 REPAIR 02P.SDR SIMA20220626004Shear Tie · corrodedSSI 53-23-005 AFT GALLEY LH SHEER PANEL IS CORRODED (MARKED) (LEVEL 2 CORROSION) -C/A-RAR AFT GALLEY LH SHEER PANEL IAW EMB-175 SRM 51-40-08SDR SIMA20220625007Seat Track · corrodedSSI 53-23-005 LH FLOOR SEAT TRACK CORRODED BETWEEN FR 80 AND FR 81. (LEVEL 2 CORROSION) -C/A-ACCOMPLISHED SPLICE DEVICE REPAIR TO LH FLOOR SEAT TRACK BETWEEN FR 80 AND FR 81 IAW EMB 175 SRM 53-00-10 REPAIR 02P.SDR FDEA202206251548None · noneCENTRE CARGO COMPARTMENT FOUND BILGE AREA LONGERON SPLICE STATION 5-113 TO 1541, LONGERON-49 LEFT CRACKED.SDR FDEA202206251547None · noneCENTRE CARGO COMPARTMENT FOUND BILGE AREA STATION 5-113 TO 1541, LONGERON-43 RIGHT LONGERON SPLICE SUSPECT CRACKED.SDR FDEA202206251546None · noneCENTRE CARGO COMPARTMENT FOUND BILGE AREA STATION 5-113 TO 1541, LONGERON-52 LONGERON SPLICE SUSPECT CRACKED.SDR FDEA202206251545None · noneCENTRE CARGO COMPARTMENT FOUND BILGE AREA STRINGER SPLICE STATION 5-113 TO 1541, LONGERON-50 RIGHT CRACKED.SDR SIMA20220625006Floorbeam · corrodedSSI 53-23-005 COROSION ON RH FLOOR BEAM BETWEEN FRAMES 84-90. -C/A-PERFORMED PERMANENT REPAIR TO RH FLOOR BEAM BETWEEN FRAMES 84-90 IAW ERS-EJ-53MR-4585.SDR SIMA20220625004Floorbeam · corrodedCORROSION ON LH BEAM BETWEEN FR 85-89. (LEVEL 2 CORROSION)-C/A-RAR LH BEAM SPLICE BETWEEN FR 85-89 IAW EMB 175 SRM 51-40-08SDR SIMA20220625005Floor Splice · corrodedSSI 53-23-005 COROSION ON RH FLOOR SPLICE AT FRAME 90. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED FLOOR SPLICE AT FRAME 90 IAW EMB 175 SRM 51-40-08SDR SIMA20220625003Panel Support · corrodedSSI 53-23-005 CORROSION ON RH PANEL SUPPORT BETWEEN FRAMES 89-91. (LEVEL 2 CORROSION)-C/A-REMOVED AND REPLACED RH PANEL SUPPORT BETWEEN FRAMES 89-91 IAW EMB 175 SRM51-40-08SDR IXXA2022062501Pressure Web · corrodedRIGHT WHEEL WELL PRESSURE PANEL CORRODEDSDR SIMA20220624002Floor Panel · corrodedSSI 53-10-027 CORROSION ON RH FLOOR SILL IN FWD GALLEY AREA BETWEEN FRAMES 13-14. (LEVEL 2 CORROSION)-C/A-RAR FWD GALLEY RH FWD FLOOR SILL AT FR 13-14 IAW EMB-175 SRM 51-40-08SDR SIMA20220624001Floor Splice · corrodedSSI 53-23-005 AFT GALLEY RH CENTER FLOOR SPLICE CORRODED AT FR 90.(LEVEL 2 CORROSION)-C/A-RAR AFT GALLEY RH CENTER FLOOR SPLICE AT FR 90 IAW ERB 175 SRM 51-40-08.SDR AALA202206287568Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT STRINGER 21L LOCATED BETWEEN BS 727 AND BS 727A. REPAIRED STRINGER PER SRM 53-00-03-2R-1.SDR IPXA2022062483456Floor Panel · damagedINSPECTION TYPE:A300FWD CARGO PNL# 131 DE HAS EDGE DAMAGEREPAIR IAW SREO-A300-5320-42722-FSDR IPXA2022062483455Spar Plate · damagedINSPECTION TYPE:A300FWD CARGO FLOOR PNL#132 RG HAS EDGE DAMAGEREPAIR IAW SREO A300-5320-42722-FSDR UIEA2022062400663Floorbeam · noneDEVIATION FOR SB 747-53A2443 UPPER DECK FLOORBEAM INSPECTION AND MODIFICATION(<P>1) ACCOMPLISHED JOB IAW EI T2022A53M-1591 REV 1. 2) CONDITION CHECK NORMAL AND JOB COMPLETED</P>)SDR IPXA2022062483444Angle · crackedINSPECTION TYPE:1CRH KRUGER FLAP WING AREA HAS A CRACK ON INNER BRACKET/ANGLE DOT 90-36REMOVED AND REPLACED IAW SRM 51-40-21SDR CALA2022062401571None · corrodedAFT CABIN L2 DOORWAY, SHAPE SILL HAS CORROSION ON AFT END (NR 32 255). ON REMOVAL OF THE SHAPE SILL, CORROSION WAS FOUND. ON THE TOP FACE OF THE DOOR SILL. CORROSION WAS REMOVED AND FOUND OUT OF LIMITS AND REPLACED SHAPE SILL, DOOR SILL AND CORNER FITTINGSSDR CALA2022062401576None · corrodedCABIN FLOOR SUPPORT STRUCTURE, FR65-FR66, Y-1732, BEAM WITH CORROSION (NR 32193) FLOOR BEAM REMOVED IAW SRM 51-72-11-911-001 AND INSTALLED NEW BE AM IAW SRM 51-42-11/001. EMP: V936191 WC: 32193 STA: ST ENG BFM SFR# 1028881SDR SWIA2022081666275Door Frame · corrodedPASSENGER DOOR SURROUND STRUCTURE FWD CLOSING FITTING HAS SEVERE CORROSION. (C-CHECK RO 8/14/2022) EVALUATED REPAIR AND FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED DAMAGED FWD CLOSING FITTING. REF. CRJ 700 SRM 51-42-06-001-001-A01, CRJ 700 SRM 51-41
Back to JASC 5310