JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2021091060830Door · dentedTHERE ARE DENTS/NICKS AROUND THE LOW PRESSURE GROUND AIR CONNECTION DOOR, MARKED WITH RED GREASE PENCIL. PLEASE PLOT/MAP AND EVALUATE THE DAMAGE. IF THE DAMAGE IS FOUND WITHIN LIMITS, ELIMINATE ALL EVIDENCE OF DAMAGE USING AIRCRAFT STANDARD PRACTICES/PROCEDURESDR SWIA2021081960455Splice Angle · corroded*CORROSION ON SPLICE ANGLE EXTERNAL FUSELAGE FS 939.00, STGR 27 (C-CHECK RO 8/18/2021) REPLACED ANGLE WITH NEW PART P# SH670-39189-1 ON SPLICE ANGLE EXTERNAL FUSELAGE FS 939.00 STGR 27 REF CRJ700 SRM 51-42-06-001-001-A01SDR SWIA2021073059841Intercostal · crackedPRESSURE FLOOR INTERCOSTAL K601R38908-2001 AT FS460 HAS CRACK AT LBL9 ATTACH FASTENER HOLE. (C-CHECK RO 7/27/2021) REPAIRED PRESSURE FLOOR INTERCOSTAL K601R38908-2001 AT FS460.00 BETWEEN LBL9 & LBL18. REF REO 601R-53-41-2940 REV -- DATED 2021-06-29, CRSDR SWIA202160467Door Frame · corrodedUPON REMOVAL OF PAX DOOR FRAME F/S 320.00 FOUND EXFOLIATED CORROSION AT LOWER CHANNEL P/N 601R318074-5 (C-CHECK RO 8/18/2021) REMOVED AND REPLACED WITH NEW THE LOWER CHANNEL ON PAX DOOR REF DWG 601R31702 REV. N AND CRJ 900 SRM 51-42-06-001-001-A01 AND SDR SWAA2021080487604Door Frame · damagedFWD ENTRY DOOR MAIN FRAME DAMAGED IN 3 EA PLACES ALONG AFT UPPER EDGES (ALL MARKED) ; / [01] REMOVED DAMAGE ON FED MAIN FRAME BS344 LBL56 WL283 0.750'X0.500';BS344 LBL58 WL280 0.500'X0.0500' AND BS344 LBL60 WL270 1.250'X0.250' I.A.W SRM 51-10-02-0G-0 AND SRM 5SDR ASAA2021062335387Shield · corrodedRH SHEILD FWD OF FWD CARGO DOOR HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED RH SHEILD FWD OF CARGO DOOR IAW B737-800 SRM 51-40-0G-0.SDR ASAA2021062335386Cargo Track · crackedRH AFT CARGO TRACK CRACKED AT STA 727E, 727G, 727H, 727J & 767. GROUNDED - YES. REMOVED & REPLACED RH AFT CARGO TRACK FROM FS 720 TO FS 767+10 IAW B737-800 SRM 53-00-53-2R-3 REPAIR 3.SDR ASAA2021062335384Bulkhead · corrodedFWD PIT STA 5001 BLKHD SUPPORT HAS CORROSION. GROUNDED - YES. REMOVED & REPLACED FWD PIT 5001 BLKHD SUPPORT IAW B737-800 SRM 51-40-02-0G-0.SDR R61A2021070800546Splice · corrodedCORROSION FOUND ON CENTER FUSELAGE III FLOOR SUPPORT STRUCTURE L/H SPLICE PLATE AT FR88. CENTER FUSELAGE III FLOOR SUPPORT L/H SPLICE PLATE AT FR 88 HAS BEEN REPLACED WITH NEW AND INSTALLED IAW EMBRAER 170-175 SRM 51-42-02SDR SWAA2021062887074Pressure Deck · crackedCRACK ON HORIZONTAL PRESSURE DECK BS 664.5; LBL 31; WL 202. FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE LIMITS PER SRM 51-10-02. CUT AND REMOVED DAMAGED WEB IAW SRM 53-40-51-2R-2. PERFORMED A DVI AROUND THE INBD & OTBD SECTIONS OF DAMAGED BEADED PRESSURESDR DALA2021062403433Crease Beam · corrodedSHIP 663 INITIAL INSPECTION: CORROSION ON RH CREASE BEAM WEB FROM STA 1160 TO 1180 AT UPPER WING BOX. CORRECTIVE ACTION: SUMMARY OF NRC 00657; ON RH CREASE BEAM WEB FROM STA 1160 TO 1180 AT UPPER WING BOX WAS REPAIRED PER ETI-57-21-259 REV. 1 AND ER/A 592253-1SDR DALA2021062403418Stringer · crackedSHIP 3238 CRACK FOUND ON CWB FRONT SPAR VERTICAL STRINGER POSITION 5 ZONE 1 AT FR 36. CORRECTIVE ACTION: REPAIRED PER ER/A 591742-14AD AND ER/A 591742-14AD REV. ORIGINAL. (1850700)SDR SWAA2021080589743Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT BS 255, RBL 4 - LBL 14, WL 207.54, FOUND TO BE OUT OF LIMITS DUE TO CREASES ARE NOT PERMITTED PER SRM 53-10-51-1A-1 STEP 4.J(3)FIGURE 105 DETAIL D. INSTALLED EWIS PROTECTION IN WORK AREA PER AMM 20-60-07-913-80.SDR SWAA2021080486481Support Frame · crackedFWD CABIN FUSELAGE SUPPORT FRAME FLANGE SMALL CRACK @ STA 312 ABOVE L-1 DOOR CUTOUT FWD MKD DOT ; / [09] LOCATED AND DRILLED REPAIR ANGLE AT FWD CABIN FUSELAGE SUPPORT FRAME AT STA 312 ABOVE L-1 DOOR IN IAW SRM 51-40-05-0G-0; [10] HEAT TREATED REPAIR ANGLE FROSDR SWIA2021070959329Splice · corrodedLH SPLICE BETWEEN FR 87/88HAS CORROSION (C-CHECK RO 7/7/2021) LH SPLICE BETWEEN FR 87/88 IS OUT OF LIMITS, NO ALLOWABLE DAMAGE IN AREA REF SRM 51-75-16. REMOVED AND REPLACED LH SPLICE BETWEEN FR 87/88 REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRSDR IPXA2021070171200Rib · crackedINSPECTION TYPE:2CRH MLG W/W CUT-OUT RIB CRACK AT FWD O/B JAMB.REMOVED,FABRICATED AND REPLACED CRACKED RIB IAW SRM 51-31-01 AND 51-35-01 (MINOR).SDR CALA2021062300940Stop Fitting · crackedR1 DOOR FRAME 16 STOP FITTING #7 UPPER AND LOWER INBOARD HOLES ARE CRACKED IN THE INTERCOSTAL FITTING AT 6:00. INTERIM REPAIR ACCOMPLISH IAW PART 1 OF ECRA 5311-02584. REPLACED THE R1 DOOR FRAME STOP #7 INTERCOASTAL FITTING IAW ECRA 5311-02584. ACCOMPLISH INITSDR IPXA2021070171203Door Frame · crackedINSPECTION TYPE:2CMAIN CABIN L3 DOOR JAMB AFT LOWER WEB AT STA.1313 & Z= -16.5 IS CRACKED.REPAIRED CRACKED MAIN CABIN L3 DOOR JAMB AFT LOWER WEB AT STA. 1313 & Z= -16.5 IAW SRM 53-40-15, REPAIR 3, FIG 201. (MAJOR)SDR REXA2021062900477Doubler · corrodedLOWER TCAS ANTENNA INTERNAL DOUBLER AT FS 300.00 IS CORRODED. REMOVED TCAS ANTENNA IAW CRJ 900 AMM 34-43-07-000-801-A02 AND REMOVED AND REPLACED TCAS DOUBLER IAW CRJ 900 SRM 51-42-06-001-
001-A01 AND 51-42-21-001-001-A01. REINSTALLED TCAS ANTENNA IAW CRJ 90SDR LR7A2021062102831Beam · crackedDURING SCHEDULED B-2 CHECK UNDER JOB CARD HB3200, FOUND LH MLG WHEEL WELL FS497 BOW BEAM LOWER FITTING CRACKED AT WL143.5, LBL61. / REPAIR BY REPLACEMENT ACCOMPLISHED IAW LOCKHEED SMP583 SRM, CH. 51-60 & 51-70. NR# 0128. / PSE# 53-40-14, AD 2012-06-09SDR DALA2021062303394Crease Beam · corrodedSHIP 663 CORROSION ON LH CREASE BEAM WEB BTW STA 1040 TO 1060 IN REF NRC 00652. CORRECTIVE ACTION: SUMMARY OF NRC 00831. LH CREASE BEAM WEB BTW STA 1040 TO 1060 WAS REPLACED PER B 757-200 SRM. (1846845)SDR REXA2021080600530Housing · crackedEXTERNAL POWER RECEPTACLE HOUSING IS CRACKED JC 900-24-900-902 - REMOVED AND REPLACED WITH NEW EXTERNAL POWER RECEPTACLE HOUSING IAW CRJ 900 REO 670-53-11-029CSDR SWIA2021081060222Door Frame · corrodedPAX DOOR FRAME AT FS313.56 BETWEEN DD4 AND DD5 (FWD) CORRODED (C-CHECK RO 8/6/2021) PAX DOOR FRAME AT FS313.56 BETWEEN DD4-DD5 FWD REPLACED REF DWG 601R31702 REV N, CRJ 700 SRM 51-42-06-001-001-A01. COMPLIED WITH 51-900-1002-SKY, ALL CHECKS GOODSDR IPXA2021071771780Longeron · bentINSPECTION TYPE:SVFWD CARGO LONGERON 44R BETWEEN STA 1099 - 6-30 HAS DEFLECTION.REPAIRED DEFLECTED FWD CARGO LONGERON 44R BETWEEN STA 1099 - 6-30 IAW UPS EO MD11-5320-80859-A. REF. FAA FORM 8100-9 (MAJOR).SDR IPXA2021071871808Splice Plate · bentINSPECTION TYPE:SVR/H SIDE FUSELAGE SPLICE PLATE IS BENT AT STA 1129 JUST BELOW L44R.REPAIRED R/H SIDE FUSELAGE SPLICE PLATE AT STA 1129 JUST BELOW L44R IAW UPS EO #MD11-5310-80845-A.SDR IPXA2021071971845Skin · tornINSPECTION TYPE:SVFORWARD LWR FUSELAGE SKIN IS TORN AT STA.1002-6-50.00 LONG 41R-47R.REPAIRED TORN SKIN AT LOWER FUSELAGE STA.1002-6.50.00 LONG 41R-47R IAW UPS EO MD11-5310-80738-A AND 8100-9 (MAJOR).SDR IPXA2021071971841Finger Doubler · dentedINSPECTION TYPE:SVFORWARD CARGO COMPARTMENT FINGER DOUBLER DENTED BETWEEN STA. 919-1019 BETWEEN LON41R-44R.REPAIRED DENTED FINGER DOUBLER BETWEEN STA.919-1019 LON 41R-44R IAW UPS EO MD11-5310-80738-A AND 8100-9 (MAJOR).SDR FDEA202106181625Bracket · cracked#3 ACM RAM AIR INLET SHELL BRACKET THAT IS MOUNTED BELOW THE AVIONINCS RACK IS BROKEN. REMOVED & REPLACED BRACKET REF ABA7221 & MD10-30 SRM 51-33-01 VOL II.SDR SWIA2021062859170Door Frame · deformedTHE FWD CARGO DOORS (FWD AND AFT) HAVE DEFORMED THRESHOLDS/DOOR JAMBS. (C-CHECK RO 6/22/2021) REPLACED THE FWD CARGO DOORS (FWD AND AFT) THRESHOLDS/DOOR JAMBS WITH SERVICABLE DOOR JAMBS (2EA P/N=9846301-1) REFERENCING CRJ 900 AMM 25-52-01-000-802-A02 SDR CALA2021061800895Beam · crackedMOP SEAL AT STUB BEAM 616R CRACKED-N/R 061:29-5710-1-2814/001 00 135-5866697 REPAIRED CREASE BEAM AT STUB BEAM AT STA. 616R/H SIDE IAW B737-7 CTION OF REPAIR AT 36,000 FLIGHT CYCLES OR 12 YEARS AFTER REPAIR INSTALLATION WITH REPEAT INSPECTIONS AT 36,000 FLIGHTSDR FDEA202106171699Door Frame · wornMAIN CARGO DECK, LH SIDE, STA. 535, LONG 23, FRAME GOUGED BY LOWER HINGE HARDWARE OF CARGO NET BRACKET. DOT #10. REMOVED DAMAGED PREVIOUS "L" ANGLE REPAIR AND INSTALLED NEW REPAIR AT STA. 535 LONGERONS 22 TO 25 REF. MD10-30 SRM 53-30-00 FIG. 13 SHEET 1 VOLSDR FDEA202106171698Door Frame · damagedMAIN CARGO DECK, LH SIDE, STA. 535, LONG 20, FRAME GOUGED BY UPPER HINGE HARWARE OF CARGO NET BRACKET. DOT #9. REMOVED PREVIOUS "L" ANGLE REPAIR AND INSTALLED NEW REPAIR AT STA.535 LONGERON 18 TO 21 REF. MD10-30 SRM 53-30-00 FIG. 14 SHEET 1 VOL.1SDR SWIA202160538Door Frame · corrodedFOUND CORROSION ON PAX DOOR FRAME FS 313.56,DD4 AND DD5 PART # 601R318086-1. (C-CHECK RO 8/18/2021) REMOVED AND INSTALLED PAX DOOR FRAME AND CLEAT PER CRJ 900 SRM 51-42-06-001-001-A01 & DWG 601R31702 REV N. LEAK CHECK GOOD / COMPLIED WITH SKYWEST FORM MSDR SWIA202160530Door Frame · corrodedCORROSION FOUND ON PAX DOOR FRAME AT FS 320.00 PART # 601R318032-5. (C-CHECK RO 8/18/2021) REMOVED AND REPLACED PAX DOOR FRAME AT FS 320.00 REF DWG 601R31702 REV. N AND CRJ 900 SRM 51-42-21-001-001-A01 AND CRJ 900 SRM 51-42-06-001-01-A01. LEAK CHECKSDR SWAA2021071985222Crease Beam · corrodedCORROSION ON CREASE BEAM INNER CHORD STA 639-644; RBL 65; WL 208; UPPER SURFACE. ; / [01] REMOVED CORROSION ON CREASE BEAM INNER CHORD STA 639-644; RBL 65; WL 208; UPPER SURFACE. DIMENSIONS OF DAMAGE REMOVAL AREA FOUND TO BE 5.5' X 1' WITH A MAX DEPTH OF 0.015SDR SWAA2021071485091Beam · corrodedCORROSION ON B.S. 270 LATERAL BEAM AT L.B.L. 10 - R.B.L. 10; W.L. 207.54. REMOVED EXISTING REPAIR AT BS 270 LBL.10 TO RBL.10 WL.207.54 IAW SRM 51-40-02-0G-0. FABRICATED A -1 STRAP AS SHOW IN SKETCH 2 REPAIR SKETCH FROM 0.063'' IAW EA-1-753-28470 STEP 8. VERSDR AALA202107097762Flange · crackedAIRCRAFT IN BASE MAINTENANCE: AFT FASTENER HOLE HAS A CRACK IN UPPER FLANGE OF RIGHT SIDE BOX BEAM AT FR43. CUT OUT DAMAGED AREA, INSTALLED FILLER AND NEW REINFORCING BRACKET FITTING REF EO 5315Y066.SDR JJBA20210616029Window Post · crackedFF2 LH COCKPIT WINDSHIELD LATERAL POST TOP EXTERNAL SKIN ONE RIVET HOLE FOUND CRACKED. SKIN CUT OUT DONE. UPPER STIFFENER ABOVE PILOT WINDOW FOUND CRACKED. CRACK ON LH COCKPIT WINDSHIELD LATERAL POST EXTERNAL SKIN REPAIRED. UPPER STIFFNER ABOVE PILOT WINDOW RESDR SWIA202158814Door Frame · crackedTRANSFER FROM EAML 660702 : TRANSFERRED FROM CAMP 22966043. PASSENGER DOOR AFT FRAME HAS A CRACK RUNNING APPROX. 3" ALONG ANGLE JUST BELOW WHERE DOOR PULLEY IS ATTACHED. (R-O 6/19/21 - IN SERVICE - FILED CLOSED)REPAIRED MCD AFT FORMER UNDER PULLEY MOUNTING SDR SWIA202160528Door Frame · corrodedSERVICE DOOR LOWER SURROUND STRUCTURE FOUND CORRODED AT F/S339.--00 (C-CHECK RO 8/18/2021) SERVICE DOOR THRESHOLD ATTACH FITTING AT F/S 339.00 REPLACED IAW CRJ900 SRM 51-42-06-001-001-A01, 51-21-16-001-001-A01 TEMP REV-51-0068 AND DWG SH670-31950 REV -YSDR SWAA2021080489920Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. ; / [01] EVALUATED DENTS ON FLIGHT DECK FLOOR AT BS 255; RBL 4 - LBL 14; WL 207.54. DENTS FOUND TO BE GOUGED; THEREFORE; DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1; FIG. 10SDR AALA202107303042Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: 0.789 INCH CRACK ON SHEAR PLATE AT FR69 AND STR 23R. REPLACED SHEAR PLATE IAW DWG D53474180 AND A321 SRM 51-42-11-801.SDR AALA202107062711Splice · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON SPLICE COUPLING MEASURING L= 1.250 INCHES, W= 0.025 INCHES, D= 0.030 INCHES LOCATED AT FR66 AND -Y1292. REPLACED COUPLING PER SRM 51-72-11-911-001, SRM 51-42-11-801 AND DWG 53472816.SDR REXA2021062400462Housing · crackedSERVICE DOOR PROX. SENSOR HOUSING IS CRACKED. J/C 52-840-503. ADJUSTED PROXIMITY SWITCH ON THE HANDLE MECHANISM TO (1.27MM) AND OPPS CHECK IAW AMM CRJ200-52-70-06-820-001. REMOVED & REPLACED SERVICE DOOR PROX. SENSOR HOUSIG IAW CRJ 200 AMM 52-41-00.SDR SWAA2021062183395Pressure Deck · crackedCRACK IN HORIZONTAL PRESSURE DECK BS 668; WL 202; RBL 202. BEGAN REMOVING FASTENERS IN THE REPAIR AREA IAW SRM 51-40-02. REMOVED PRESSURE SEAL AT BS 663.75-680 RBL51 IAW SRM 53-40-51-2R-2 STEP 4A(1). CUT AND REMOVED THE DAMAGED PART OF THE WEB IAW SRM 53-SDR CALA2021061500881Beam · crackedMOP SEAL AT STUB BEAM 616R CRACKED-N/R 061:29-5710-1-2814/001 00 135-5866697SDR FDEA202106151548Landing · crackedPANEL 197KL HYD ACCESS PANEL LATCH LANDING IS MISSING AND ATTACH BRACKET IS CRACKED REMOVED AND REPLACED TEE CLIP PER FEDEX EA # F-5320-T0362153-P1SDR SWIA2021081060298Cleat · corrodedSTRINGER TO FRAME ATTACHMENT CLEAT AT FS1031 STR24R HAS CORROSION (C-CHECK RO 8/9/2021) REMOVED AND REPLACED CLEAT AT FS1031 STR24R IAW CRJ 700 SRM 51-42-21-001-001-A01, SEE CONTINUATION FOR SPECIFIC WORK ACCOMPLISHEDSDR V0XD20210716003Window Post · crackedLH SIDE WINDSHIELD POST CRACKED. CORRECTIVE ACTION: REMOVED AND REPLACED LH SIDE WINDSHIELD POST IAW CRJ900 SRM51-42-20 AND 51-42-06. WORK PERFORMED ON AVMAX W/O:80943 W/C: 2341SDR SWAA2021070785430Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. ; / [01] BEGAN REMOVING FASTENERS IN THE REPAIR AREA IAW SRM 51-40-02; [02] FLIGHT DECK FLOOR ATDENTED AREA FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1; [03] REMOVED DAMAGED FLIGHT
Back to JASC 5310