SDR ASAA2021070635540Beam · gougedCABIN FLOOR STRUCTURE CENTER BEAM HAS GOUGE AT FASTNER HOLE APPROXIMATELY 5 INCHES FWD OF FR14 NEAR FLIGHT DECK DOOR AREA RH SIDE, STREAMER ATTACH AND MARKED IN REDDOT:S303 GROUNDED - YES. BLENDED GOUGED AREA. LOSS OF.100- FOUND OUT OF LIMITS IAW A320 SRM 53SDR ASAA2021070635538Beam · corrodedFWD ENTRY DOOR CUTOUT LOWER FWD CORNER CORRODED AT FASTENER HOLE 4 EACH GROUNDED - YES. ACCOMPLISHED REPAIR ON FWD ENTRY DOOR LOWER SILL IAW AIRBUS A320 SRM 53-11-14. THIS IS A CATEGOR "B" REPAIR WITH AN INSPECTION THRESHOLD OF 60,000FC REF A320 SRM 53-1-14-20SDR IPXA2021072071889Doubler · crackedINSPECTION TYPE:2CCLG W/W L/H FWD PRODUCTION DOUBLER LOCATED APPROX. STA 1381 IS CRACKED.REMOVED AND REPLACED CRACKED CLG W/W L/H PRODUCTION DOUBLER AT APPROX. STA 1381 IAW SRM 51-33-01. (MINOR)SDR IPXA2021071771781Fitting · corrodedINSPECTION TYPE:SVFWD CARGO SIDE GUIDE RAIL SUPPORT FITTING AT STA 1009 AND BETWEEN LONGERON 41R & 42R IS CORRODED.REMOVED CORRODED FWD CARGO SIDE RAIL SUPPORT FITTING, FABRICATED AND INSTALLED REPLACEMENT FITTING AT STA 1099 BETWEEN LONGERON 41R & 42R IAW SRMSDR P5CA2021063000251Fitting · crackedRH CANTED PRESSURE DECK, A FASTENER HOLE OF OUTERMOST FITTING WAS FOUND 2EA CRACKS AT APPROX. STA 1241 RBL 125.(<P>RH CANTED PRESSURE DECK. STA 1241 RBL 125 FASTENER HOLE REPAIRED AS PER RI-53-45-14705 REV A.</P>)SDR 2A6R202107016114Bracket · corrodedDURING A 1000 HOUR AIR FRAME INSPECTION FOUND THE PILOT'S SIDE OF THE COCKPIT FLOOR GROUND BRACKET CORRODED AT F.S. 1700 WHEN THE GROUND BRACKET WAS REMOVED, FOUND THE FLOOR CORRODED IN THE UPPER AND LOWER SKINS IN MULTIPLE SPOTS.SDR SWIA2021081960407Lintel · crackedPAX DOOR LINTEL 3 JUST AFT OF FS 280 CRACKED (C-CHECK RO 8/18/2021) -SERVICE BULLETIN 670BA-53-040, REVISION C, DATED: 12-06-2012, FUSELAGE - CENTER FUSELAGE, PRIMARY STRUCTURE / FS280.00 TO FS295.00 - INSPECTION OF LINTEL STRINGER 3 OF THE MAIN PASSDR SWIA2021091360990Crossbeam · corrodedR/H CROSS BEAM AT FS 1051.30 & RBL 39.00 HAS CORROSION NEXT TO FLOOR SILL. (C-CHECK RO 9/8/2021) CORROSION ON RH CROSS BEAM AT FS1051.30 AND RBL 39.00 NEXT TO FLOOR SILL REF. CRJ-900 SRM, 51-21-06-001-001-A01. COMPLIED WITH REPAIR REF. REO 690-53-61-102SDR SWIA2021091060873Fitting · chafed*EVALUATE CHAFE ON RH WHEEL WELL WING LINK FITTING ATTACHED TO REAR SPAR. MARKED (C-CHECK RO 9/8/21) REPAIRED CHAFE ON RH WHEEL WELL WING LINK FITTING (ATTACHED TO REAR SPAR) BY COMPLYING WITH ALL STEPS OF REO 670-57-11-180 REV -- DATED 2021-07-30. COMPLSDR SWIA2021091060871Fitting · chafed*EVALUATE CHAFE ON LH WHEEL WELL WING LINK FITTING ATTACHED TO REAR SPAR. MARKED (C-CHECK RO 9/8/21) REPAIRED CHAFE ON LH WHEEL WELL WING LINK FITTING (ATTACHED TO REAR SPAR) BY COMPLYING WITH ALL STEPS OF REO 670-57-11-179 REV -- DATED 2021-07-30. COMPLSDR SWIA2021091060868Door Frame · crackedFWD EQUIPMENT COMPARTMENT - L/H DOOR FRAME - AFT DOOR LATCH CUTOUT HAS SUSPECTED CRACK IN RADIUS (C-CHECK RO 9/8/21) REMOVED AND REPLACED L/H ELECTRICAL BAY DOOR LANDING REF CRJ700 SRM 51-42-06-001-001-A01 AND REO 670-53-11-1721 REV-- DATED 2021-08-12 COMSDR SWIA2021091060866Door Frame · crackedFWD EQUIPMENT COMPARTMENT - R/H DOOR FRAME - AFT DOOR LATCH CUTOUT CRACKED IN RADIUS (C-CHECK RO 9/8/21) TRANSFERED FROM CO: 101451221 JOB:: 710145121 OP: 123 / REMOVED CRACKED RH TRU BAY LANDING, REF CRJ700 SRM 51-42-06-001-001 A01.INSTALLED NEW R/H TRSDR SWIA2021091060863Door Frame · crackedFWD EQUIPMENT COMPARTMENT - L/H DOOR FRAME - LWR AFT CORNER OF DOOR CUTOUT HAS SUSPECTED CRACK (C-CHECK RO 9/8/21) REPLACED FWD EQUIPTMENT COMPARTMENT SKIN FOR L/H DOOR FRAME, LWR AFT CORNER CUTOUT CRACK REF CRJ-700 SRM 51-42-06-001-001-A01, CRJ-700 AMM 5SDR REXA2021090300689Door Frame · corrodedPAX DOOR FRAME CORRODED ON INSIDE OF PNL 832FL. REMOVED CORROSION PAX DOOR FRAME @ PNL ACCESS 832FL IAW CRJ900 SRM 51-21-11, FOUND TO IN LIMITS IAW ENDEAVOR AIR EA# CRJ 952-11879SDR SWIA2021081960397Window Post · crackedSUSPECTED CRACK ON PILOT'S WINDSHIELD POST, AT UPPER BARREL NUT HOLE. (C-CHECK RO 8/18/2021) REMOVED CRACKED POST AND INSTALLED NEW L/H COCKPIT WINDSHIELD SIDE POST REF CRJ700 SRM 51-42-21-001-001-A01 AND DWG# 601R33007 REV-U / COMPLIED WITH SKYWEST SKYSDR IXXA2021080400047Fitting · corrodedIN COMPLIANCE OF TASK CARD 51-041-02 " RESTORATION OF CANTED PRESSURE CAVITY CLEANING" THE FOLLOWING FINDINGS WERE NOTED: LEFT REAR SPAR
FITTING STATION 955.6 INCHES FROM FITTING INBOARD ON UPPER CENTER WING SKIN CORROSION FOUND. WORK IN PROGRESSSDR ASAA2021070335513Frame · crackedFRAME AT STA 520 IS CRACKED JUST BELOW STR 8 L/H AT I/B HOLE OF SUPPORT BRACKET. GROUNDED - YES. REPAIRED FRAME IAW FIG 5 OF AD20090102-700-25-1L.SDR AALA202107156008Stringer · corrodedAIRCRAFT IN BASE MAINTENANCE: STRINGER SURFACE CORROSION AT FR56 TO FR57 AND STR 43L. REMOVED CORRODED AREA AND INSTALLED SPLICE REPAIR ON STRINGER 43L REF EA 328889 AND REPAIR DRAWING R53470620 ISSUE F.SDR SWIA2021081960395Landing · crackedRH TRU BAY DOOR LANDING WAS POSSIBLE CRACKED AT AFT HINGE (MARKED) (C-CHECK RO 8/18/2021) REMOVED UNSERVICEABLE AND INSTALLED SERVICEABLE RH TRU BAY DOOR LANDING REF MHIRJ REO 670-53-11-1709 REV --, DATED: 2021-07-12. DRAWING NO# CC670-33040 REV G AND SDR SWIA2021081860352Window Post · crackedRH WINDSHIELD SIDE POST, CRACK RADIATING FORWARD OUT OF THE TOP BARREL NUT HOLE. (C-CHECK RO 8/16/2021) REMOVED AND REPLACED RH WINDSHIELD SIDE POST, REF. CRJ700 SRM 51-42-21-001-001-A01 AND DRAWING 601R33007 REV. U. PRESSURIZATION LEAK CHEAK GOOD. SEE SDR SWIA2021081860351Window Post · crackedLH WINDSHIELD SIDE POST, CRACK RADIATING FORWARD OUT OF THE TOP BARREL NUT HOLE. (C-CHECK RO 8/16/2021) REMOVED AND REPLACED LH WINDSHIELD SIDE POST, REF. CRJ700 SRM 51-42-21-001-001-A01 AND DRAWING 601R3307 REV. U. PRESSURIZATION LEAK CHEAK GOOD. SEE CSDR SWIA2021091360954Plate · corroded* FOWARD BAGGAGE BAY, FWD TIE DOWN RING PLATE AT LBL3.4 CORRODED (MARKED) (C-CHECK RO 9/8/2021) INSTALLED NEW FWD TIE DOWN RING PLATE FORWARD BAGGAGE BAY LBL3.4 PER CRJ900 SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 AND DWG: SH670-33600 REV Y. COSDR SWIA2021091360951Doubler · corroded* FOWARD BAGGAGE BAY, CENTER DOOR SURROUND, FWD JOINT PLATE ON RING DOUBLER CORRODED (MARKED) (C-CHECK RO 9/8/2021) REMOVED CORROSION AND EVALUATED REPAIR. REPAIR FOUND TO BE WITHIN LIMITS OF REO 690-53-31-593 REV. -- DATED: 2021-07-14 / SEE CONTINUATIOSDR SWIA2021091360935Stop Fitting · corroded* GALLEY SERVICE DOOR SURROUND ALL FOUR FLOOR PROTECTOR PLATE WEBS CORRODED (MARKED) (C-CHECK RO 9/8/2021) REMOVED AND REPLACED ALL FOUR (2EA PN: SH670-32040-3 AND 2EA. PN: SH670-32040-4) GALLEY SERVICE DOOR SURROUND FLOOR PROTECTOR PLATE WEBS. REF CRJ9SDR SWIA2021081960394Door Frame · corrodedFORWARD BAGGAGE BAY DOOR SURROUND STRUCTURE UNDER THE AFT JOINT PLATE HAS EVIDENCE OF CORROSION APPROX. FS581 ON STRG 25 LH (C-CHECK RO 8/18/2021) REPAIRED FWD BAGGAGE BAY DOOR SURROUND STRUCTURES UNDER THE AFT JOINT PLATE REF REO 670-53-31-682 REV--SDR AALA202107068111Splice · elongatedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLE ON SPLICE COUPLING LOCATED AT FR64 AND -Y1292. REPLACED COUPLING PER SRM 51-72-11-911-001, SRM 51-42-11-801 AND DWG 53472832.SDR CALA2021070101016Window Frame · damagedREFERENCE ECRA 5310-07862 LH FR4 LATERAL WINDOW FRAME UPPER STIF FENER-INTERIM REPAIR. PER PART 1 STEP "8" "BEFORE FURTHER FLIGHT PERFORM A PERMANENT REPAIR PER PART 3 OF ECRA 5310-07862 ." ACCOMPLISH A PERMANENT REPAIR AT LH LATERAL WINDSHIELD FR 4 STIF FENESDR 2A6D2021070185002Deck Plate · chafedTHE RH TRANSMISSION DECK EDGING (PN 350A21-1041-22) HAS A GOUGE THAT IS UP TO 0.200” IN DIAMETER AND ALMOST THROUGH THE PART.SDR SWIA2021091360927Door Frame · corroded*PASSENGER DOOR €“ FORWARD FORMER IS CORRODED ON MULTIPLE AREAS AND ELEMENTS. (MARKED) (C-CHECK RO 9/8/2021) REMOVED AND REPLACED CORRODED PAX DOOR FWD FORMER. REF CRJ900 SRM 51-42-21-001-001-A01, CRJ900 SRM 51-42-06-001-001-A01, DWG 601R31702 REV-N. SDR AALA202107013264Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON R4 DOOR SILL BEAM AT FR68 AND RBL -Y1500. REPAIRED PER SRM 53-41-14-300-001 AND EA 328360.SDR AALA202107010836Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON L4 DOOR SILL BEAM AT FR68, BUTT LINE Y-1500. REPAIRED WITH NESTED ANGLE REINFORCEMENT PER EA 328360.SDR FDEA202106291615Rib · crackedRIB CRACKED REMOVED AND FABRICATED NEW RIB AND INSTALLED PER DOUGLAS DWG ANB7143 AND SRM 51-31-00 VOL 2SDR SWAA2021072689394Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. ; / [01] EVALUATED DENTED AREA ON FLIGHT DECK FLOOR BS 255 RBL 4 - LBL4 L=6.0 ; W=4.0 ; Y= .060 ; Y/W=66 ; FOUND TO BE OUT OF LIMITS IAW SRM 53-1051-1A-1 STEP 4;J;(3) FIG 105 ; DETAIL SDR AALA202107150253Web · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED WEB AT RBL 32 AND STA 990. INSTALLED REPAIR TO RIGHT WEB IAW EA 328816, AARD 51-00-05 & SRM 51-40-02.SDR SWIA2021081960388Door Frame · corrodedSERVICES DOOR SURROUND STRUCTURE HAS A SPOT OF CORROSION FWD SIDE AT APPROXIMATE FLOOR LEVEL FS319.70 (C-CHECK RO 8/18/2021) REMOVED ATTACHING ANGLE (FITTING) P/N SH670-31990-1 AT APPROX FS 319.00 AND INSTALLED A NEW SERVICIABLE UNIT REF. CRJ700 SRM 51-SDR IPXA2021071871807Splice · crackedINSPECTION TYPE:SVR/H SIDE FUSELAGE SKIN SPLICE DOUBLER AND PLATE IS CRACKED AND BENT AT STA 1129. BETWEEN L42R AND L48R.REPAIRED R/H SIDE FUSELAGE SKIN SPLICE DOUBLER AND PLATE AT STA 1129. BETWEEN L42R AND L48R IAW UPS EO # MD11-5310-80845-A.SDR R61A2021071000556Seal Rest · corrodedFWD CARGO DOOR CUT-OUT, LOWER BEAM, CORROSION FOUND ON MID SEAL REST BETWEEN FR 25-26. FWD CARGO DOOR CUTOUT LWR BEAM MID SEAL REST BTW FR 25-26 REPLACED IAW AMM 20-10-01, SRM 51-40-02SDR AALA202107155774Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: FORWARD CARGO LEFT TRANSITION PANEL CORRODED AT STA 500D +7 AND LBL23. REPLACED TRANSITION PANEL STA 500D TO 500I IAW SRM 53-00-53-2R-5 AND AARD 51-00-05 AND BOEING DRAWING # 143A7501.SDR AALA202107131488Crease Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT CREASE ANGLE ON INNER CHORD BETWEEN 947 TO 997 AND STR 17R. INSTALLED INNER CHORD IAW 51-40-02.SDR DALA2021062803486Pressure Deck · crackedSHIP 3238 CRACK INDICATION ON FRAME 36 PRESSURE DECK MEMBRANE IN FASTENER HOLE 2 AT 2.5 IN FROM -Y1523 (RH) IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER ER/A 591866-14AD PRI REV.0, REV.1, REV.2, AND ER/A 591866-14AD REV. ORIGINAL. (1855526)SDR DALA2021062803485Pressure Deck · crackedSHIP 3238 CRACK INDICATION ON FRAME 36 PRESSURE DECK MEMBRANE IN FASTENER HOLE 3 AT 3.8 IN FROM -Y1523 (RH) IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER ER/A 591866-14AD PRI REV.0, REV.1, REV.2, AND ER/A 591866-14AD REV. ORIGINAL. (1855525)SDR DALA2021062803484Pressure Deck · crackedSHIP 3238 CRACK INDICATION ON FRAME 36 PRESSURE DECK MEMBRANE IN FASTENER HOLE 5 IN FROM -Y1523 (RH) IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: REPAIRED PER ER/A 591866-14AD PRI REV. 0 REV. 1 REV. 2 AND ER/A 591866-14AD REV. ORIGINAL. (1855519)SDR ASAA2021062635390Pressure Web · crackedLH PRESSURE WEB AT STA 663 HAS A CRACK IN LOWER ATTACH ANGLE, CRACK RUNS FROM NUTPLATE ATTACH HOLE TO SLOT IN ANGLE. GROUNDED - YES. REPAIRED LH PRESSURE WEB ATTACH ANGLE IAW EA 800-57EA-23636.SDR ASAA2021062635389Pressure Web · crackedRH PRESSURE WEB AT STA 663 HAS HOLE SHOWING CRACK INDICATION (CLOCKED AT 12:00 POSTION) HOLE IS THE OB COUNTERSUNK HOLE NEXT SLOT. GROUNDED - YES. REPAIRED STA 663 CRACK IAW EA 800-57EA-23637.SDR ASAA2021062635388Pressure Web · crackedRH PRESSURE WEB AT STA 663 ATTACH ANGLE IS CRACKED AT IB NUTPLATE OB NUTPLATE ATTACH HOLE TO WEB SLOT. GROUNDED - YES. REPAIRED ATTACH IAW EA 800-57EA-23637.SDR VNAA202106279991Stub Frame · crackedCRACK IN STUB FRAME LOCATED AT FS 1015 STR 18L-19L P/N MM670-36123-003 CAUSED BY IMPACT TO LOWER CARGO DOOR AREA FROM BELT LOADER VEHICLE
CA: REPAIRED STUB FRAME LOCATED AT FS 1015 STR 18L-19L IAW REO 670-53-61-1919 DATED 6-23-2021SDR SWIA2021082060542Window Post · crackedCOPILOTS WINDSHIELD SIDE POST WAS FOUND TO HAVE A CRACK DURING NDT (C-CHECK RO 8/19/2021) REPLACED WINDSHIELD SIDE POST (CO-PILOT) IAW CRJ700 SRM 51-40-11, 51-42-21, 51-21-11, 51-21-16, 51-42-06, 51-45-00 AND BOMBARDIER DWNG CC670-33055.SDR SWIA2021082060541Window Post · crackedPILOTS WINDSHIELD SIDE POST WAS FOUND TO HAVE A CRACK DURING NDT (C-CHECK RO 8/19/2021) REPLACED WINDSHIELD SIDE POST (PILOT) IAW CRJ700 SRM 51-40-11, 51-42-21, 51-21-11, 51-21-16, 51-42-06, 51-45-00 AND BOMBARDIER DWG CC670-33055SDR GTIA2021062835828Window Post · crackedRH WINDSHIELD POST AT FR.4 UPPER ATTACHMENT HAS CRACK INDICATION ON 3 HOLES. REF HAECO NRI 36284. RAF-01 273805401 OPENED-ACCOMPLISHED BUSHING REPAIR AND FWD LOWER FITTING REPLACEMENT ON RH FR 4 UPPER IAW A319 SRM 51-44-11 AND 51-42-11 REF REO L 23253, EO 53SDR DALA2021062503451Crease Beam · corrodedSHIP 663 CORROSION ON LH CREASE BEAM WEB BTW STA 940 TO 960 IN REF NRC 00652. CORRECTIVE ACTION:SUMMARY OF NRC 00832; CREASE BEAM WEB WAS REPLACED PER B-757-200 S.R.M. (1852431)