JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2021050600342Tee Fitting · corrodedR/H FS 280 BULKHEAD CROSSBEAM IS CORRODED. - REMOVED AND REPLACED R/H CROSSBEAM, UPPER DOUBLE ANGLE, LOWER DOUBLER ANGLE, TEE FITTING AT RBL 9 AND J-ANGLE IAW CRJ 700 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-20-001-001-A01, 51-42-13-001-001-A01, 5SDR REXA2021050600341Crossbeam · corrodedR/H FS 280 BULKHEAD CROSSBEAM IS CORRODED. - REMOVED AND REPLACED R/H CROSSBEAM, UPPER DOUBLE ANGLE, LOWER DOUBLER ANGLE, TEE FITTING AT RBL 9 AND J-ANGLE IAW CRJ 700 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-20-001-001-A01, 51-42-13-001-001-A01, 5SDR REXA2021051800340Crossbeam · corrodedR/H FS 280 BULKHEAD CROSSBEAM IS CORRODED. - LOCATED,DRILLED AND INSTALLED NEW SERVICEABLE FS 280 CROSSBEAM P/N CC670-34175-7 PER CRJ 700 SRM 53-11-41-201-003-A01. WVAC EMP #7322SDR SWAA2021051069497Pressure Deck · damagedCOCKPIT FLOOR DAMAGED STA 269 LBL 10.5' THRU 15' ; /SDR DALA2021050702581Stop Fitting · crackedSHIP 3262 CRACK INDICATION FOUND ON FR16 RH STOP FITTING 7 HOLE 1 AND HOLE 3. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR PER PRI #591423-14AD REV.0 AND ER/A #591423-14AD REV.ORIGINAL. (1801514)SDR CALA2021050600617Door Frame · crackedR1 DDOR FRAME 16 STOP FITTING #7 LWR IN BOARD HOLE IS CRACKED IN THE INTERCOSTAL FITTING AND UPPER INBRD HOLE IS CRACKED IN THE WEB AND INTERCOSTAL REPAIR BEFORE NEXT FLIT CONTACT ENG. FOR APP ROVED INSTRUCTIONS PER NR 9292145/22145 AD 2019-20-10. REPAIRED R1SDR CALA2021050600620Stop Fitting · crackedR2 DOOR FRAME 68 AT STOP FITTING #1 AFT SIDE OF FRAME STR.22 IN UPPER RADIUS RADIUS. CRACK INDICATION RUNNING INBOARD TO OUTBOAR D. "CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS BEFORE NEXT FLIG HT." PER HAECO LCQ N/R 9290296/20296 GENERATED BY V061633 COMPLETESDR 2021F00112Doubler · crackedCRACK DAMAGE, NOSE LANDING GEAR WHEEL WELL (NWW), FRAME, WEB, AND DOUBLERS, FS 75. 7413133-10, -15, -16, 7413133-59. ACCOMPLISHED TEXTRON AVIATION FIELD REPAIR SR-680A-ATA53-25890 REV- DATED JUNE 1, 2020 AND 8100-9 DATED 6/1/2020; STANDARD REPAIR - CRACK DAMAGSDR SWAA2021061677188Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. ; / EVALUATED FLIGHT DECK FLOOR DENTS AT BS 255; RBL 4 - LBL 14; WL 207.54. DENTS ON FLOOR FOUND TO BE GOUGED; THEREFORE; DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1. REPAIRSDR R61A2021052000438Service Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND AFT WASTE SERVICE PANEL CORRODED BTWN FR 86-89 STR 24RH-26RH. REPLACED WASTE SERVICE PANEL PN 170-86668-403 IAW SRM 51-41-02. SEE AAR NRC#4500901-1000-0104 FOR WORK PERFORMED. AC REMAINS IN YQG FOR COMPLETION.SDR CALA2021050600615Door Frame · crackedR2 DOOR FRAME 68 AT STOP FITTING #1 AFT SIDE OF FRAME STR.22 IN UPPER RADIUS RADIUS. CRACK INDICATION RUNNING INBOARD TO OUTBOAR D. "CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS BEFORE NEXT FLIG HT." PER HAECO LCQ N/R 9290296/20296 GENERATED BY V061633 COMPLETESDR DALA2021050602574Door Frame · crackedSHIP 3244 CRACK INDICATION ON FRAME 66 LH SIDE ON OPEN FASTENER HOLE H4 ON DOOR STOP FITTING 1 POSITION. CORRECTIVE ACTION: PERFORMED REPAIR ON FRAME PER SRM A320 53-41-12. REPAIR WILL BE CONTINUED ON MONITOR. (1800523)SDR DALA2021050602573Door Frame · crackedSHIP 3244 CRACK INDICATION ON FRAME 68 RH SIDE DOOR STOP FITTING 1 ON OPEN FASTENER HOLE H4. CORRECTIVE ACTION: PERFORMED REPAIR PER SRM A320 53-41-12. (1800520)SDR DALA2021050602572Crossbeam · damagedSHIP 3244 ELONGATED (CORROSION) HOLE FRAME 20 ON CROSSBEAM OPEN HOLE 30 RH. CORRECTIVE ACTION: PERFORMED REPAIR PER PRI 590182-14AD REV.0, REV.1, REV.2, REV.3 AND ER/A 590182-14AD REV. ORIGINAL. (1800512)SDR DALA2021050602571Crossbeam · crackedSHIP 3244 CRACK INDICATION ON FRAME 20 RH SIDE CROSSBEAM. CORRECTIVE ACTION: PERFORMED REPAIR PER PRI 590182-14AD REV.0, REV.1, REV.2 REV.3 AND ER/A 590182-14AD REV. ORIGINAL. (1800509)SDR FY4Y202110001Beam · crackedLONGITUDINAL FLOOR LONGITUDINAL FLOOR BEAM FOUND TWO CRACKS BETWEEN BS705 AND 715 RBL 24.82, CRACKS SIZE 3.0 INCH AND 1.5 INCH IN AREA.SDR IPXA2021051169278Fitting · crackedINSPECTION TYPE:C2CENTER LOWER AUX TANK ANGLE FITTING CRACK AT RH O/B STA. Y1278.REMOVED,FABRICATED AND REPLACED CRACKED ANGLE FITTING IAW SRM 51-33-01 AND 51-30-01 (MINOR).SDR UIEA2021050701089Door Frame · brokenFOUND MAIN DECK CGO L5 ENTRY DOOR FWD FRAME BROKEN(<P>REMOVED AFFECTED FASTENERS TO GET ACCESS IAW SRM 51-40-02 REV 91. REPAIRED DAMAGED AREA IAW SRM 53-60-15-2R-3 REPAIR 3 REV 91 AND EI NO. T2021A53M-1269 REV 1. REINSTALLED FASTENERS IAW <SPAN>SRM 51-40-02 RESDR FDEA202105041137Skin · crackedLH UPPER A/C PACK EXHAUST CUTOUT HAS SUSPECTED CRACK IN UPPER AFT CORNER THRU FASTENER HOLE. REPAIRED FUSELAGE SKIN PER MD10-30 SRM 53-50-00 FIG 3ASDR SIMA20210504001Not Reported · damagedTRANSFERRED FROM NRWC 005-XNA-00533 ITEM 2, REFER NRWC 005-XNA-00533 ITEM 1, DAMAGED AREA REQUIRES MORE BLENDING AND OR REPAIR. MAJOR REPAIR-C/A-PERFORMED PERMANENT REPAIR IAW ERS-EJ-53MR-4335 PT. A.SDR JR2R20210504803Rib · crackedLH WHEEL WELL FRAME 52 CRACKEDSDR SWIA202158128Door Frame · crackedPAX DOOR CUTOUT, UPPER/FWD STOP-FITTING IS CRACKED. (FILED CLOSED) REMOVED AND INSTALLED NEW PAX DOOR CUTOUT, UPPER/FWD STOP-FITTING WITH SERVICEABLE PART IAW CRJ 200 SRM 51-42-21. / REF CP 22736778 FOR OPS CHECKS DISCREPANCIES.SDR SWIA202158078Window Post · crackedREF. CP 22727381 CRACK ON R/H WINDOW SIDE POST (P/N 601R33223-2) MEASURING .5€? LONG. THE CRACK GOES THROUGH THE FULL THICKNESS OF THE WEB FROM FWD SURFACE TILL THE BARREL NUT HOLE. THIS IS CLASSIFIED AS A MAJOR REPAIR. FORM M-337 INITIATED. (FILED CLOSEDSDR DALA2021050402534Profile · crackedSHIP 3244 GOUGE EMERGENCY EXIT DOOR 843 FORWARD LOAD TRANSMITTING PROFILE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED TRANSMITTING PROFILE PER A320 SRM 51-72-11. (1798907)SDR DALA2021050402533Window Frame · crackedSHIP 3244 CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE CONTINUITY FITTING RH SIDE. CORRECTIVE ACTION: PERFORMED REPAIR PER ERA 590966-14AD REV.ORIGINAL AND PRI 590966-14 REV.0. (1798759)SDR SWIA2021072259705Window Post · cracked* CO-PILOT WINDSHIELD SIDE POST HAS SUSPECTED CRACK AT TOP BARREL NUT HOLE. (C-CHECK RO 7/20/2021) REMOVE AND REPLACED DAMAGED CO-PILOT WINDSHIELD SIDE POST REF CRJ700 SRM 51-42-21-001-001-A01 AND DWG CC670-33055 REV F. / COMPLIED WITH 51-900-1002 SKY.SDR SWIA202158146Seal Rest · corrodedCORROSION FORWARD CARGO DOOR CUTOUT, ON THE LOWER FORWARD SEAL REST IN 3 LOCATIONS (RIVET BUCKTAILS ON 2 NUTPLATES AND 1 SPOT ON EDGE UNDER LATCH FITTING), X= 305", Y= +17", Z=-63". (C-CHECK RO 5/8/2021) REMOVED AND REPLACED (2EA) NUTPLATES ON THE FORWSDR SWIA202158145Seal Rest · corrodedCORROSION FORWARD CARGO DOOR CUTOUT, ON THE LOWER AFT SEAL REST IN 2 LOCATIONS (RIVET BUCKTAILS ON 2 NUTPLATES), X= 345", Y= +17", Z=-63". (C-CHECK RO 5/8/2021) REMOVED AND REPLACED RIVETS ON THE 2 NUTPLATES FORWARD CARGO DOOR CUTOUT, ON THE LOWER AFT SSDR SWIA202158144Seal Rest · corrodedCORROSION FORWARD CARGO DOOR CUTOUT, ON THE LOWER CENTER SEAL REST IN 4 LOCATIONS, X= 325", Y= +17", Z=-63". (C-CHECK RO 5/8/2021) REMOVED AND REPLACED FORWARD CARGO DOOR CUTOUT, ON THE LOWER CENTER SEAL REST REF EMB SRM 51-40-08SDR AALA202105100787Beam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INTERNAL STRUCTURE BEAM FR35.5 AT LEVEL STR42L IN FORWARD CARGO COMPARTMENT. REPLACED INTERNAL STRUCTURE BEAM IN FORWARD CARGO COMPARTMENT IAW A321 SRM 51-42-11-801 AND DWG D53235029.SDR SWAA2021050468288Door Frame · corrodedR/H AFT LAV (FO'S SIDE); AFT LOWER DOOR FRAME POST HAS EVIDENCE OF CORROSION. (TRANSFERED FROM LP#1869821) / REMOVED CORROSION PER EA 21-125-01207 ENGINEERING WILL TRACK FOLLOW UP ACTIONS PER EA 21-125-01207-TLD SAM 326 A1201474SDR DALA2021050402531Crossbeam · crackedSHIP 3244 CRACK INDICATION FOUND AT OPEN HOLE H8 LOC. CROSSBEAM SPLICING FR16 R/H. CORRECTIVE ACTION: PERFORMED REPAIR PER ERA 590967-14AD REV. ORIGINAL AND PRI 590967-14 REV.0. (1797958)SDR SWIA2021072259703Door Frame · corrodedPAX DOOR FORMER F/S 320.163 AND FWD CLIP COMMON TO FORMER ARE CORRODED (C-CHECK RO 7/20/2021) REPLACED PAX DOOR FORMER FS320.163 AND CLIP WITH NEW REF CRJ-700 SRM 52-11-06-001-001-A01, 51-42-21-001-001-A01 AND DWG# 601R31702 REV N. COMPLIED WITH TASK CSDR SWIA2021072259701Cleat · corrodedPAX DOOR CLEAT COMMON TO FRAME F/S 313.56 IS CORRODED (C-CHECK RO 7/20/2021) REMOVED AND INSTALLED NEW PAX DOOR CLEAT COMMON TO FRAME F/S313.56 IAW CRJ 700 SRM 51-42-06-001-001-A01 AND BOMBARDIER DWG 601R31702 REV. N AND RESTORED FINISH ALL FASTENERS ANSDR SWIA202159478Beam · corrodedFOUND CORROSION ON THE FS 333 TRANSVERSE BEAM 7" O/B OF LBL 9 AROUND A NUTPLATE LOCATION AND AT RADIUS OF FLANGE GOING ONTO THE WEBNEAR VERTICAL POST. (C-CHECK RO 7/10/2021) REPAIRED FS333 TRANSVERSE BEAM 7" OUTBOURD OF LBL9 IAW REO 670-53-21-2035 REV -SDR SWAA2021060772566Stringer Clip · crackedCRACK SERVICE DOOR CUT OUT TIE CLIP LOCATED BS 277 STRINGER 10R AT FWD GALLEY AREA / REPLACED TIE CLIP SERVICE DOORCUT OUT LOC BS277 STR10R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG #141A1110 REV.-SDR REXA2021050600298Bulkhead · damagedR/H 9G BULKHEAD HAS 20EA AREAS OF DAMAGE AROUND POTTED INSERTS. REPAIRED RH 9G BULKHEAD IAW MHIRJ ENGINEERING ORDER CL-600-2B19-53-L06720 REV IR, DATED 4/15/2021.SDR REXA2021050600297Bulkhead · damagedCENTER 9G BULKHEAD HAS 6EA AREAS OF DAMAGE AROUND PUTTED INSERTS REPAIRED CENTER 9G BULKHEAD IAW MHIRJ ENGINEERING ORDER CL-600-2B19-53-L06719 REV IR, DATED 4/15/2021.SDR REXA2021050600296Bulkhead · damagedL/H 9G BULKHEAD HAS 19EA AREAS OF DAMAGE AROUND POTTED INSERTS. REPAIRED RH 9G BULKHEAD IAW MHIRJ ENGINEERING ORDER CL-600-2B19-53-L06718 REV IR, DATED 4/15/2021.SDR SWIA2021072259700Post · corrodedFS 280 RH BL12L POST HAS EVIDENCE OF CORROSION AT FLOOR LEVEL. (C-CHECK RO 7/20/2021) PERFORMED DOOR POST REPAIR AT FS280.00 RH BL 12L. REF CRJ700 SRM 53-11-10-201-006-A01. SEE CONTINUATION CARD FOR WORK PERFORMED. COMPLIED WITH SKYWEST TASKCARD 51-900-SDR V0XD20210503002Lintel · crackedPASSENGER DOOR LINTEL AT F.S. 280 IS CRACKED. CORRECTIVE ACTION: REPAIRED CRAQCKED LINTEL AT F.S. 280 IAW REO 670-53-21-493 REV. D DATED 2015-07-10 AND SB 670BA-53-040 REV. C DATED SEPT 20, 2012SDR SWAA2021060367778Former · crackedFAIRING FORMER CRACKED AT INBOARD EDGE; BS 663; RBL 28. / REPAIRED CRACKED FAIRING FORMER AT INBOARD EDGE; BS 663 RLB 28 IAW EA 21-157-01380 REV IR AND ATS ER 21-01853 REV IRSDR IPXA2021051569411Window Frame · corrodedINSPECTION TYPE:2CPILOT'S L1 WINDSHIELD LOWER FRAME IS CORRODED.REPAIRED CORRODED PILOT'S L1 WINDSHIELD LOWER FRAME IAW VT-SAA EA 011-5310-01-A9109 REV. IR AND UPS EO MD11-5310-80380-A. (MINOR)SDR IPXA2021051069132Spar · crackedINSPECTION TYPE:A300LH O/B SIDE OF THE CENTER SPAR WEB BOOTOM HOLE HAS A CRACK INDICATION AT THE 6 O CLOCK POSITION. LH I/B SIDE OF THE CENTER SPAR WEB TOP HOLE HAS A CRACK INDICATION AT THE 9 O CLOCK POSITIONREAMED HOLE TO REMOVE CRACK, FABRICATED AND INSTALLSDR IPXA2021051069131Spar · crackedINSPECTION TYPE:A300RH O/B SIDE OF THE CENTER SPAR WEB BOTTOM HOLE HAS A CRCK INDICATION AT 3 O CLOCK POSITIONREAMED HOLE TO REMOVE CRACK, FABRICATED AND INSTALLED REPAIR BUSHINGS AND REPAIR WASHERS IAW EA# A300-5310-27-A2590 AND EO#A300-57010-8025-ASDR AALA202104299009Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FIRST OFFICER'S RIGHT WINDOW FRAME AT STA 211.8 REQUIRES REINFORCING REPAIR. INSTALLED DOUBLER/TRIPLER REPAIR REF SB 737-53-1335.SDR AALA202104299008Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CAPTAINS LEFT WINDOW FRAME AT STA 211.8 REQUIRES REINFORCING REPAIR. INSTALLED DOUBLER/TRIPLER REPAIR REF SB 737-53-1335.SDR R61A2021042900373Crossbeam · corrodedWHILE IN HEAVY CHECK - MAJOR REPAIR - FR90 CROSSBEAM FOUND CORRODED. REPLACED CROSSBEAM IAW SRM 51-41-01SDR SWIA2021070959332Doubler · crackedFWD EQUIPMENT COMPARTMENT - DOUBLER UNDER ADG HAND PUMP CRACKED AS MARKED (C-CHECK RO 7/7/2021) INSTALLED RHS-7 TYPE 2 DOUBLER IAW REO#670-53-11-509 REV-D DATE 2016/06/29 AND REF CRJ900 SRM 51-42-06-001-001-A01. / COMPLIED WITH 51-900-1002-SKYSDR AALA202104299005Seal Depressor · crackedAIRCRAFT IN BASE MAINTENANCE: AFT CARGO COMPARTMENT AFT CUTOUT FRAME LOWER CORNER HAS ORANGE DEPRESSOR SEAL CRACKED. REPLACED SEAL DEPRESSOR PER SRM 51-40-02.
Back to JASC 5310