JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2020102301204Shear Tie · crackedSHEAR FITTING AT STA 540 AND RBL 15.04 IS CRACKED. SPT 5867694 REMOVED AND REPLACED CRACKED SHEAR FITTING AT STA 540 RBL 15.04, IAW B737-700 SRM 51-40-02 AND ECRA 5714-01164 SSFR REPORT FORM 4 6-0024 ENTERED BY UAL INSPECTION U355204 10/21/2020 INSPECTION COMSDR SWIA202054353Bracket · crackedRT WINDSHIELD SIDEPOST LOWER AFT BRACKET IS CRACKED. C-CHECK RO 11/24/2020. REMOVED DAMAGED RT WINDSHIELD SIDEPOST LOWER AFT BRACKET. LOCATED, DRILLED, AND INSTALLED NEW SERVICEABLE BRACKET, IAW CRJ200. COMPLETED TASK CARD, FORM M-337 ATTACHED. WEIGHT ANDSDR SWAA2020111624841Crease Beam · corrodedCORROSION, ON CREASEBEAM WEB ATTACH ANGLE STA 664 RBL 67 WL 208 UPPER SURFACE, MARKED. REMOVED CORROSION ON CREASEBEAM WEB ATTACH ANGLE STA 664 RBL 67 WL 208 UPPER SURFACE. MAX MATERIAL REMOVED FROM .056' 7075T6 LOT NR 1331117-2. REMOVED OLD AND LOCATED & DSDR SWAA2021081024593Panel · damagedPANEL 193B HAS ELONGATED FASTENER HOLES. / REPLACED PANEL193B PER SRM 51-40-02 AND EO#14108SDR SWAA2020112329180Pressure Deck · dentedDENT FLOOR PANEL BS 257 LBL 12 AT COCKPIT (1 EA). REPAIRED FLIGHT DECK FLOOR WEB LOCATED FROM BS 250 TO BS 270 BETWEEN RBL 10 AND LBL 20, IAW SWA EA NR 1-A53-33179 REV 1.SDR FDEA202010192558Structure · damagedCUSTOMER REQUEST, EVALUATE FASTENER SPACING ON ATTACHMENT ANGLE AT BL 0 FWD OF FRAME AT STA 231.25. REMOVED AND REPLACED CHORD AND INTERCOSTAL, PER DWG 141N8222 AND EA F-5310-T0357422. TITLE;FUSELAGE-MAINFRAME-INTERCOSTAL, STA 273 TO 231, BL 0.SDR SWAA2020112324911Stub Frame · crackedCRACK FRAME STUB LOCATED S-7 TO S-9 AND BS 294.5 RT SIDE AT PASSENGER CABIN (1 EA). REPLACED FRAME STUB LOCATED S-7 TO S-9 AND BS 294.5 RT SIDE AT PASSENGER CABIN, IAW B737-700 SRM 51-40 -02 AND DWG 141A8370 REV D.SDR SWAA2020111624252Pressure Deck · crackedDURING COMPLETION OF CCN 753-201-00-02 FOUND HORIZONTAL PRESSURE DECK CRACKED ON LEFT SIDE AT BS 663 WL 201 LBL 30 AND 32. ALSO AT BS 673 WL201 LBL 30 AND 38, AREAS MARKED. REMOVED DAMAGE PART OF THE HORIZONTAL PRESSURE DECK BS 663-674 LBL 30-LBL 60 WL 201 ASDR SWIA202053798Beam · corrodedCORROSION FOUND AT LBL 9 FS 295 LONG BEAM, MARKED. C-CHECK RO 11/1/2020. REMOVED CORROSION, REF CRJ700 SRM. ALL STEPS COMPLIED WITH OF FINAL REO. SEE CONTINUE CARD FOR DETAILS OF WORK PERFORMED. O2 SYSTEM FAILED LEAK CHECK. SEE JOB 71033061 OP 245 MXTRANSDR A6WA202010207333Pressure Deck · corrodedLT PRESSURE FLOOR SILL PANEL AT FS 537 AND LBL 47 HAS CORROSION. AIRCRAFT REMOVED FROM SERVICE. REMOVED CORROSION ON PRESSURE FLOOR SILL PANEL AT FS 537 AND LBL 47, PER REO 601R-53-41-666 DATED 2012-11-06 REV-C AND CRJ 200 SRM 51-21-06. REWORK AREA MEASURESSDR FDEA202010160017Cap · crackedLT WING, FUSELAGE STRUCTURE SEEN THROUGH WING BODY FAIRING 154AB, STA 1156 STRINGER 39, FITTING CRACKED, MARKED. REPAIRED AREA REFERENCE EA 8-5310-T0357883.SDR TIPR2020121444218Door Frame · gougedMAIN CARGO DOOR CUTOUT UPPER SILL GOUGED BETWEEN STA 400 AND 420, REPAIRED.SDR SWIA202054227Support Bracket · crackedLT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 469.63 CRACKED, FLAGGED. C-CHECK RO 11/21/2020. REMOVED & INSTALLED NEW LT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 469.63, REF CRJ 200 SRM & MHI-RJ DWG. SEE CONTINUATION CARD FOR MORE DETAILS. COMPLIED WITSDR SWIA202054226Support Bracket · crackedLT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 449.85 CRACKED, FLAGGED. C-CHECK RO 11/21/2020. REPLACED LT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 449.85 WITH NEW ONE. C/W REF CRJ-200 SRM DWG.SDR SWIA202054225Support Bracket · crackedLT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 476.67 CRACKED, FLAGGED. C-CHECK RO 11/21/2020. REMOVED & INSTALLED NEW LT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 476.67, REF CRJ 200 SRM & MHI-RJ DWG. SEE CONTINUATION CARD FOR MORE DETAILS. SEE ATTACHEDSDR SWIA202054224Support Bracket · crackedRT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 476.67 CRACKED, FLAGGED. C-CHECK RO 11/21/2020. REMOVED AND REPLACED NEW SUPPORT BRACKET AT RT OVERWING ACCESS PANEL FS 476.67, REF CRJ200 SRM AND DWG. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH ATTACHED TASSDR SWIA202054223Support Bracket · crackedRT OVERWING ACCESS PANEL SUPPORT BRACKET AT FS 449.85 CRACKED, FLAGGED. C-CHECK RO 11/21/2020. REMOVED AND REPLACED NEW SUPPORT BRACKET P/N 601R31037-48 AT RT OVERWING ACCESS PANEL FS 449.85, REF CRJ200 SRM AND DWG. SEE CONTINUE CARD FOR DETAILS. COMPLIED SDR SWAA2020111629163Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT BS 255 RBL 4-LBL 14 WL 207.54. REPAIRED FLIGHT DECK FLOOR DAMAGE AT BS 255 RBL 4-LBL 14 WL 207.54, PER ER 20-03451 REV IR AND EA NR 20-153-02181 REV IR.SDR ASAA2020101633469Beam · crackedUPON REMOVAL OF R1 DOOR MOP SILL FOUND FWD REVEAL CRACKED. GROUNDED-YES. REPAIRED R1 DOOR MOP SILL FWD REVEAL STUB BEAM, IAW B737-700 SRM 53-10-15-2R-7 & ASA EA 700-53EA-22996 THIS IS A CAT A REPAIR WITH NO FURTHER REQUIRED INSPECTIONS.SDR SWIA202053786Beam · corrodedAFT CARGO BEAM CTL III P/N 170-91857-001. SHALLOW LINE OF FRETTING WEAR AND CORROSION, AS MARKED. C-CHECK RO 10/31/2020. REMOVED AND REPLACED AFT CARGO BEAM CTL III P/N 170-91857-001, REF AMM.SDR SWAA2020110223588Pressure Deck · damagedFLIGHT DECK FLOOR DAMAGED AT BS 263 WL 208 LBL 14 TO RBL 4. REMOVED DAMAGE SECTION ON FLIGHT DECK FLOOR, PER B737-700 SRM 51-10-02-0G-0 AND EA NR 1-A53-33179 FIG 1 REV 1. FABRICATED REPAIR PARTS-1 REPLACEMENT WEB -2 DOUBLER AND -3 DOUBLER, PER EA 1-A53-33179SDR 2020FA0000448Spar · crackedAIRCRAFT WAS UNDER AN 2020 ANNUAL INSPECTION. FAA ASI WERE ON SITE PERFORMING AS IA AUDIT. NOTICED A STRUCTURAL CRACK (1/4 INCH) AND GOUGE ON STRUCTURAL ON LOWER CORNER ON SPAR ASSEMBLY-FUSELAGE CENTER SECTION-FORWARD ATTACH POINT, SEE PHOTOS.SDR SIMA20201015004Web · gougedSERVICE DOOR CUTOUT REINFORCING WEB IS GOUGED JUST ABOVE THE DOOR HINGE. C/A: INSTALLED FABRICATED FILLER, SHIM, AND INTERNAL DOUBLER ON SERVICE DOOR REINFORCING WEB, IAW ENVOY ERS-EM-53MR-4214.SDR FDEA202010152499Skin · crackedHIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT ON LEFT HAND SIDE EXTERNAL SURFACE OF THE FUSELAGE SKIN WITHIN A 2 INCH RADIUS OF ALL HOLES COMMON TO THE UNDERWING LONGERON AND THE FUSELAGE SKIN AND FOUND 1 EACH CRACK APPROXIMATELY 0.75 INCHES LENGTH, AS MASDR SWIA202053781Doubler · corrodedFWD WET AREA CORROSION LT FLOOR DOUBLER AT FR 19 CORRODED, AS MARKED. C-CHECK RO 10/31/2020. REMOVED AND REPLACED FWD WET AREA LT FLOOR DOUBLER AT FR 19, REF EMB175 SRM.SDR SWIA202053774Crossbeam · corrodedAFT WET AREA CORROSION CENTER SPLICE ON CROSSBEAM FR 90 IS CORRODED, AS MARKED. C-CHECK RO 10/31/2020. REMOVED AND REPLACED CENTER SPLICE ON CROSSBEAM FR 90, REF EMB SRM.SDR FDEA202010152498Structure · crackedDURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION CARRIED OUT ON REMOVED FASTENER HOLES ON RIGHT HAND SIDE VERTICAL FLANGE OF THE SPAR CHORD AT UNDERWING LONGERON LOWER WING BODY STATION 1035 APPROXIMATELY RIGHT HAND BUTTLINE 82AND FOUND 01 EACH LOWESTSDR FDEA202010152497Structure · crackedDURING HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION CARRIED OUT ON REMOVED FASTENER HOLES ON LEFT HAND SIDE VERTICAL FLANGE OF THE SPAR CHORD AT UNDERWING LONGERON LOWER WING BODY STATION 1035 APPROXIMATELY LEFT HAND BUTTLINE 82 AND FOUND 01 EACH LOWEST SDR SWIA202053959Door Frame · corrodedFS 280 BOTTOM OF INBOARD PORTION OF LT 280 DOOR FRAME CORRODED, AS MARKED. C-CHECK RO 11/11/2020. REPAIRED FS 280 BOTTOM OF INBOARD PORTION OF LT 280 DOOR FRAME, REF CRJ 700 SRM. ALL STEPS COMPLIED WITH. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202053958Door Frame · corrodedFS 280-BOTTOM OF INBD PORTION OF RT 280 DOOR FRAME CORRODED, AS MARKED. C-CHECK RO 11/11/2020. REPAIRED FS 280 BOTTOM OF INBOARD PORTION OF RT 280 DOOR FRAME, REF CRJ 700 SRM. ALL STEPS COMPLIED WITH. SEE CONTINUATION CARD FOR DETAILS.SDR FDEA202010142789Doubler · crackedCENTER WHEEL WELL FWD BULKHEAD RT OUTBOARD SPOILER PUSH/PULL M.J RODS FEED THROUGH DOUBLER LOWER AFT CORNER CRACKED. P/N AEA0526. R & R THE DOUBLER (P/N-AEA0526U2) WITH HI-LOK, PER SRM 51-33-01 VOL-II.SDR FDEA202010142487Beam · crackedNDT INSP LT CENTER WING JOINT AT FR 40 MID HOLE FOUND CRACKED SIGNAL. REAMED THE HOLE THROUGH ALL LAYERS STEP BY STEP 0.4OMM EACH TIME NOT EXCEED R2 DIMENSION, PER A300-600F SRM51-40-44. PERFORMED ROTO-TEST INSPECTION AND NO CRACK FOUND, PER A300-600F NTM51-SDR SWIA202054292Frame · bentCARGO DOOR MID FWD FS 574 TRACK FRAME ASSEMBLY ON AFT FACING SIDE BENT CORNER. C-CHECK RO 11/21/2020. REMOVED CRACKED CHANNEL P/N 601R35050-25 AT AFT CARGO DOOR TRACK ASSEMBLY FS 574, REF CRJ200 SRM. INSTALLED NEW CHANNEL PN 601R35050-25 AT CARGO DOOR FWD TSDR SWIA202054291Frame · gougedCARGO DOOR UPPER FWD TRACK FRAME ASSEMBLY ON AFT FACING SIDE BENT AND GOUGED. C-CHECK RO 11/21/2020. REMOVED AND INSTALLED NEW CARGO DOOR UPPER FWD TRACK ASSEMBLY, REF DWG AND CRJ 200 SRM.SDR SWIA202054282Plate · corrodedMID CARGO HOLD DOWN PLATE CORRODED BETWEEN FRAMES 589.0 AND 605.0, MARKED. C-CHECK RO 11/21/2020. REMOVED AND REPLACED WITH NEW MID CARGO HOLD DOWN PLATE BETWEEN FRAMES 589.0 AND 605.0 CRJ200 SRM.SDR SWIA202054077Angle · corrodedLT 280 POST J ANGLE ATTACH CLIP CORROSION. FOUND DOOR POST CLIPS TO BE CORRODED OUT OF LIMITS. CORROSION DEPTH .013, MAX ALLOWED IS .006. REMOVED AND REPLACED CORRODED DOOR POST ATTACH CLIPS, IAW CRJ-700 SRM. WVAC TENG4886 CAL DATE:15-JUN-20 DUE 30-JUN-21 SDR SWIA202053688Crossbeam · damagedCROSS FRAME 87 HAS ARC DAMAGE (THROUGH) ON THE UNDERSIDE OF THE FLANGE ABOVE HARNESS W121. C-CHECK RO 10/26/2020. COMPLIED WITH ETD2020-170-030036 FOR PERMANENT REPAIR OF ARC DAMAGE ON CROSS FRAME 87 ABOVE HARNESS W121. THIS REPAIR DOES NOT ADVERSELY AFFECTSDR AALA202010269022Expansion Joint · crackedAIRCRAFT IN BASE MAINTENANCE. CRACK IN EXPANSION JOINT AT STA 540 AND LBL 1. REPLACED EXPANSION JOINT WITH NEW, IAW DRAWING 143A0060 AND AARD 51-00-05-1.SDR AALA202010239019Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION OF CENTER FITTING AT FR 68 AND STR 23R, MEASURING L=3.479 IN, W=0.754 IN, D=0.033 IN. REPLACED CENTER FITTING WITH NEW, IAW SRM A321 51-42-11-801 AND DRAWING D53480505.SDR SWIA202053824Door Frame · corrodedPAX DOOR FRAME FS 327.763 IS CORRODED. C-CHECK RO 11/3/2020. REPLACED FRAME AT FS327-763 P/N 601R318062-3, REF CRJ700 SRM AND DWG. LEAK CHECK IS GOOD. SEE CONTINUATION FOR DETAILS.SDR R61A2020102400717Crossbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND CENTER FUSELAGE 1 FLOOR STRUCTURE CORRODED AT CROSS BEAM AT FR 14 UPPER FLANGE RT SIDE. MX REPAIRED CROSSBEAM UPPER FLANGE, IAW SRM 53-00-10 REPAIR 03. SEE AAR NRC 4500788-2000-0102 FOR WORK PERFORMED. A/C REMAINS IN SDR SWIA202053736Door Frame · corrodedPAX DOOR FRAME FS 313.56 P/N 601R318086-1 CORRODED ON MULTIPLE SURFACES. C-CHECK RO 10/29/2020. FOUND PAX DOOR FRAME AT FS OH 313.56 TO BE OUT OF LIMITS, PER CRJ 200 SRM. REMOVED AND INSTALLED A NEW PAX DOOR FRAME AT FS.313.56, REF CRJ 200 AMM AND DWG. PSDR AALA202010199015Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. FOUND CORRODED AREA ON CORNER FITTING AT FR 66 AND STR 23R IN AFT GALLEY AREA, MEASURING L=0.566 IN, W=0.403 IN, D=0.032 IN. REPLACED CORNER FITTING, IAW A321 SRM 51-72-11-911-001, 51-42-11-801 & DWG D53480505.SDR 2020FA0000442Spar · corrodedINSPECTED REAR SPAR AND FOUND CORROSION ON AFT SPAR RT SIDE WHERE DOUBLE PLATE IS RIVETED TO SPAR. INTERGRANULAR CORROSION BETWEEN THE DOUBLE AND SPAR. ALSO NOTED RIVETS ARE POPPING OFF DUE TO THE SEVERE CORROSION.SDR ASAA2020100833426Shear Tie · crackedSTA 540 UPPER FUEL TANK SHEAR TIE CRACKED AT LBL 15. GROUNDED-YES. REMOVED CRACKED SHEAR TIE AT STA 540 LBL 15 & REPLACED WITH NEW SHEAR TIE, IAW 737-700 SRM 51-40-02-0G-0.SDR FDEA202010082440Frame Angle · dentedMAIN DECK CARGO COMPARTMENT, CABIN EXISTING REPAIR ANGLE FOUND DENTED AT LEFT HAND FRAME STATION 1661, LONGERON 12 LEFT. MAIN DECK CARGO COMPARTMENT, CABIN AT LEFT HAND FRAME STATION 1661, LONGERON 12 LEFT EXISTING DENTED REPAIR ANGLE REMOVED AND REPAIRED, ASSDR SIMA20201008003Beam · corrodedCORROSION, AFT SERVICE DOOR LOWER BEAM AT FR 85. C/A: REMOVED AND REPLACED LOWER BEAM AFT SERVICE DOOR, REF SRM 51-40-08.SDR SWAA2021021121571Rail · corrodedCORROSION ON RAIL AT AFT CARGO BAY BS927 RBL8 WL175. / REMOVED AND REPLACED RAIL IN AFT CARGO BAY BS 887- 947 RBL 8 PER ER 20-03448 REV IR & EA 20-153-02074 REV IRSDR SWAA2021021121596Track · corrodedCORROSION ON TRACK AT AFT CARGO BAY BS747 RBL13 WL156. / CORROSION WAS FOUND TO BE OUT OF LIMITS DUE TO PROXCIMITY TO FASTENER HOLES PER: SRM 53-00-53-1A-2. CARGO TRACK WILL BE REPLACED ON NRC U228143SDR SWAA2021021121578Rail · corrodedCORROSION ON RAIL AT AFT CARGO BAY BS773 LBL8.1 WL156. / OUT OF LIMITS DUE TO NO LIMITS GIVEN FOR PREVIOUS REPAIR. REMOVED AND REPLACED DAMAGED REPAIR PARTS AS PER SRM 51-40-02 AS SHOWN IN EA 1-A53-4982 REV 3
Back to JASC 5310