As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CUSTOMER REQUEST, EVALUATE FASTENER SPACING ON ATTACHMENT ANGLE AT BL 0 FWD OF FRAME AT STA 231.25. REMOVED AND REPLACED CHORD AND INTERCOSTAL, PER DWG 141N8222 AND EA F-5310-T0357422. TITLE;FUSELAGE-MAINFRAME-INTERCOSTAL, STA 273 TO 231, BL 0.