SDR IPXA2020101161174Stanchion · corrodedINSPECTION TYPE: 2C CORROSION ON VERTICAL STANCHION AT FWD CARGO AFT BULKHEAD AT STA Y=6-73 X= -28.05 BETWEEN Z= -19 Z= -117. REMOVED, FABRICATED, AND INSTALLED VERTICAL STANCHION, IAW DWG A6A7094 (MINOR).SDR IPXA2020101161173Stanchion · corrodedINSPECTION TYPE: 2C FWD CARGO AFT BULKHEAD AT STA 6-70 LT THE 5TH VERTICAL BEAM HAS CORROSION. REMOVED, FABRICATED, AND INSTALLED VERTICAL STANCHION AT STA Y=6.73 AND X= -9.05 BETWEEN Z= -19 AND Z= -117, IAW DWG AGA7094 (MINOR).SDR FDEA202009222291Crossbeam · crackedMDCC FLOOR, FR 67 Y1456-Y1959, CROSSBEAM WITH CRACK APPROXIMATELY 0.75 INCH IN LENGTH. REPAIRED MDCC FLOOR, FR 67, Y1456-Y1959 CRACKED CROSSBEAM, PER A300-600F SRM 51-40-21 & SRM 53-10-15 FIG 211. THE REPAIR CATEGORY "A" MAJOR REPAIR, IAW FEDEX GMM 6-2-100.SDR SCNA20201008124Frame · gougedGOUGE FOUND ON STA 986.5 FRAME AT RBL 46 WL 209. FOUND GOUGE TO BE OUT OF LIMITS, PER SRM 53-00-07-1A-1 4(A)1. REPLACED DAMAGED FRAME SECTION BS 986.5 JUST BELOW STRINGER 17 TO STRINGER 24 RH, PER SRM 51-40-02 AND DRAWING 147A1086 SHEET 29 AND DRAWING 147A00SDR 2020F00375Support Frame · crackedNOSE LANDING GEAR WHEEL WELL FRAME CRACK.SDR SWIA202053886Support Bracket · crackedCOPILOT WINDSHIELD SIDEPOST LOWER AFT SUPPORT BRACKET IS CRACKED. C-CHECK RO 11/11/2020. REMOVED AND REPLACED COPILOT WINDSHIELD SIDEPOST LOWER AFT SUPPORT BRACKET, IAW CRJ200 SRM. COMPLIED WITH TASK CARD AND FORM 337. NO WEIGHT CHANGE.SDR SWIA202053752Door Frame · chafedPASSENGER DOOR SURROUND STRUCTURE FORWARD PULL IN LEVER FITTING STOP CHAFED, MARKED. C-CHECK RO 10/29/2020. BLENDED OUT CHAFE, NDT'ED REPAIR, EVALUATED-OUT OF LIMITS. REMOVED AND REPLACED WITH NEW DROP DOWN DOOR STOP, REF CRJ200 SRM.SDR REXA2020100700678Plate · damagedFWD CARGO CEILING ANCHORING BRACKET FOR PANEL 151KLC HAS HOLES DRILLED INTO IT AT FS 501 AND APPROXIMATELY LBL 18. REPAIRED DAMAGE IN CROSSBEAM AT FS 501 LBL 18, IAW ENDEAVOR AIR EA CRJ 953-10861 REV A DATED 09/14/20. REPLACED 2 EA ANCHORING BRACKETS FOR PANSDR SWAA2020102320890Pressure Deck · crackedCRACK INDICATION ON WEB HORIZONTAL PRESSURE DECK LOCATED STA 675 AND RBL 43 INCH AT PASSENGER CABIN (LENGTH OF CRACK 1 INCH). PERFORMED REPAIR ON WEB HORIZONTAL PRESSURE DECK LOCATED BETWEEN STA 663 TO STA 675 AND RBL 30 TO RBL 60 AT PASSENGER CABIN, IAW SRM SDR SWIA202053344Bracket · corrodedLT WINDSCREEN INBOARD FLOOR MOUNT CORROSION W/100% MATERIAL LOSS. C-CHECK RO 10/13/2020. REPLACED CORRODED INBOARD FLOOR MOUNT WITH NEW MOUNT ON LEFT WINDSCEEN, REF C&D CMM.SDR SCNA20201008113Fitting · corrodedCORROSION FOUND AT STA 1016, STR 24R TERMINAL FITTING. CORROSION ON STR 24R TERMINAL FITTING BS 1016 FOUND TO BE OUT OF LIMITS, DUE TO NO SRM ALLOWABLE DAMAGE LIMITS FOR THIS PART. REMOVED TERMINAL FITTING. LOCATED, DRILLED AND INSTALLED NEW FITTING, PER SRSDR SWAA2020092217000Vapor Barrier · crackedFOUND CRACK ABOUT 7 IN LONG AT LEFT SIDE VAPOR BARRIER LOWER BETWEEN LBL 35 AND 33 MOD. TEMP REPAIR, PER EA 1-A57-13410. REPETITIVE INSPECTION REMOVE ALUMINUM FOIL SPEED TAPE AND INSPECT CRACK FOR ADDITIONAL GROWTH. IF NO ADDITIONAL GROWTH REAPPLY SPEED TAPESDR SWIA202053893Door Frame · dentedLT EMERGENCY EXIT TOP/FWD CORNER OF CASTING DOOR STRUCTURE DENTED AND CRACKED. C-CHECK RO 11/11/2020. REPAIRED LT EMERGENCY EXIT TOP/FWD CORNER, IAW MHIRJ REO. COMPLETED TASK CARD AND ATTACHED COMPLETED FORM 337. NO WEIGHT CHANGE. REFERENCE CONTINUATION CSDR SWIA202053498Window Post · crackedRT WINDSHIELD SIDE POST LOWER AFT FITTING IS CRACKED. C-CHECK RO 10/18/2020. REMOVED DAMAGED RT WINDSHIELD SIDE POST LOWER AFT FITTING. LOCATED, DRILLED, AND INSTALLED NEW SERVICEABLE FITTING, IAW CRJ200-SRM.SDR SWIA202053497Window Post · chafedSTRAP ON WINDSHIELD CENTER POST, ATTACHING CENTER POST TO CENTER SUPPORT CLIPS FOUND TO BE CHAFED. CAUSED BY CRACKED LT SUPPORT CLIP, P/N 601R34012-25. C-CHECK RO 10/18/2020. REMOVED DAMAGED WINDSHIELD CENTER POST STRAP AND INSTALLED NEW SERVICEABLE STRAP, SDR REXA2020100700693Crossbeam · damagedDAMAGE FOUND IN CROSS BEAM BETWEEN LBL 9 & LBL 27 AT FS 469. DAMAGE FOUND IN CROSS BEAM BETWEEN LBL 9 & LBL 27 AT FS 469. ENDEAVOR AIR EA CRJ953-10837 REV IR DATED 09/15/20. FABRICATED AND INSTALLED A NEW NUTPLATE STRAP, IAW CRJ 900 SRM 51-42-06-001-001-A01SDR AALA202009199002Stop Fitting · wornAIRCRAFT IN BASE MAINTENANCE: FOUND WEAR ON STOP FITTING DOOR CUT OUT AT LEVEL FRAME 54 AFT CARGO COMPARTMENT. REPLACED STOP FITTING, IAW SRM 51-42-11-801 AND DWG D53475500.SDR IPXA2020091860367Adapter · brokenINSPECTION TYPE: A300 MCD CLS ADAPTER AT FR20-Y1959 CROWN BROKEN OFF. REMOVED, FABRICATED, & REPLACED CLS ADAPTER, IAW UPS EO A300-5310-77583-A.SDR DALA2020091903109Pressure Deck · corrodedCORROSION LEVEL 2: DURING INSPECTION FOUND CORROSION IN MAIN CABIN PRESSURE DECK IN SEVERAL AREAS STA 1681 TO 1720 BL0 TO LBL-52. REPLACED PRESSURE DECK BETWEEN STA 1681 TO 1720 & LBL 54 TO RBL 54, PER SRM.SDR SCNA20200929053Rail · corrodedFWD CARGO AFT BULKHEAD LOWER RAIL HAS CORROSION IN SEVERAL AREAS 500 RBL 21 TO LBL 21. REMOVED CORROSION ON FWD CARGO BULKHEAD LOWER RAIL, 100% MATERIAL LOSS. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FWD CARGO AFT BULKHEAD LOWER RAIL, IAW B737-800 SRSDR EVCA202009182Xmsn Deck · crackedDURING ROUTINE MAINTENANCE, CRACK WAS VISUALLY FOUND ON THE MAIN TRANSMISSION DECK STRUCTURE. CRACK WAS REPAIRED UTILIZING STANDARD REPAIR PROCEDURES.SDR SWIA202053489Fitting · crackedWINDSHIELD CENTER SUPPORT CLIPS ON THE LT AND RT SIDE ARE CRACKED. C-CHECK RO 10/18/2020. REMOVED DAMAGED WINDSHIELD CENTER SUPPORT CLIPS ON THE LT AND RT SIDE AND INSTALLED NEW SERVICEABLE CLIPS, IAW CRJ200.SDR SWIA202053327Pressure Deck · crackedFS 461.00 AND BL 0-RBL 9, POSSIBLE CRACK ON THE PRESSURE FLOOR SKIN, MARKED. C-CHECK RO 10/13/2020. REPAIRED CRACK AT FS 461.00 AND BL 0-RBL 9 ON THE PRESSURE FLOOR SKIN BY COMPLYING WITH MHIRJ REO. PRESSURE CHECKS GOOD. SEE CONTINUATION CARD FOR DETAILS.SDR REXA2020100700694Drain · corrodedINTERCOSTAL CORRODED AT STR 21L BETWEEN FS 319.70 AND FS 333.00. REMOVED 1EA CORRODED BACK UP SILL. LOCATED, DRILLED, AND INSTALLED 1EA NEW BAUR UP SILL P/N SH670-31822-1, IAW CRJ 900 SRM 51-40-06-001-001- A01, 51-40-11-001-001-A01, 51-42-21-001-001-A01, ANDSDR SWIA202052897Stop Fitting · wornL2 DOOR, TOP FORWARD AND AFT LOWER DOOR STOPS ON FRAME WORN. C-CHECK RO 9/29/2020. REMOVED AND REPLACED L2 DOOR, TOP FORWARD AND AFT LOWER DOOR STOPS ON FRAME, REF AMM.SDR CALA2020091801122Door Frame · crackedCRACK INDICATION OBTAINED AT RT FWD DOOR STOP FITTING NR 1 FR 16 LOWER INBOARD HOLE AT 7:00 POSITION WITH LENGTH OF APPROX 0.020 IN. REF AAR N/R: 99900282 GENERATED BY : V903469 REMOVED & REPLACED INTERCOSTAL AT RT FR 16 JUST FWD OF DOOR STOP FITTING NR 1, ASSDR CALA2020091801121Door Frame · crackedCRACK INDICATIONS OBTAINED AT LT FWD PASSENGER CREW DOOR STOP NR 7 UPPER I/B FR 16 AT 5:00 POSITION WITH LENGTH APPROX 0.020', REF AAR N/R: 99900285 GENERATED BY: V903469. REMOVED AND REPLACED INTERCOSTAL AT LT FR 16 JUST FWD OF DOOR STOP FITTING, AS PER AIRBSDR IPXA2020091660299Heat Shield · dentedINSPECTION TYPE: 2C LOWER FUSELAGE APU EXHAUST HEAT SHIELD HAS 2EA DENTS. REPAIRED APU EXHAUST HEAT SHIELD, IAW VT-SAA EA NR 011-5350-01-A8541 I/R AND UPS EO NR MD11-5350-77839-A (MINOR).SDR SWIA202053554Crossbeam · crackedCARGO DOOR CUTOUT CARGO DOOR CAM TRACK CROSSBEAM ASSEMBLY LOWER AFT BRACKET SECURING CROSSBEAM TO BULKHEAD CRACKED, AS MARKED. C-CHECK RO 10/20/2020. REMOVED AND REPLACED THE BRACKET FOR CARGO DOOR CAM TRACK AFT WITH NEW PART, INSTALLED NEW 6 EA HI-LITES, RESDR SWIA202053550Door Frame · corrodedCORROSION ON SERVICE DOOR FWD FRAME FITTING AT FS 319.00, STGR 17R. C-CHECK RO 10/20/2020. REMOVED CORROSION SERVICE DOOR FWD FRAME AT FS 319.00 STGR 17R, REF CRJ 200 SRM. SERVICE DOOR FWD FRAME FITTING FOUND TO BE OUT OF LIMITS, REF CRJ-200-SRM. INSTALLEDSDR FDEA202009152324Beam · crackedNDT INSPECTION FOUND FUSELAGE MAINFRAME RT NR 2 GANTRY OUTBOARD FLANGE WITH CRACK SIGNAL AT FR 51.A. REPAIRED THE FUSELAGE MAINFRAME RT NR 2 GANTRY OUTBOARD FLANGE AT FR 51.A, PER AIRBUS DWG R53810581 ISSUE C. THIS REPAIR CATEGORY A MAJOR REPAIR, IAW FEDEX GSDR FDEA202009152323Beam · crackedNDT INSPECTION FOUND FUSELAGE MAINFRAME LT NR 2 GANTRY OUTBOARD FLANGE WITH CRACK SIGNAL AT FR 51.A. REPAIRED THE FUSELAGE MAINFRAME LT NR 2 GANTRY OUTBOARD FLANGE AT FR 51.A, PER AIRBUS DWG R53810581 ISSUE: C. THIS REPAIR CATEGORY A MAJOR REPAIR, IAW FEDEX SDR FDEA202009152322Beam · crackedNDT INSPECTION FOUND FUSELAGE MAINFRAME LT NR 2 GANTRY OUTBOARD FLANGE WITH CRACK SIGNAL AT FR 51.A. REPAIRED THE FUSELAGE MAINFRAME LT NR 2 GANTRY OUTBOARD FLANGE AT FR51.A, PER AIRBUS DWG R53810581 ISSUE: C. THIS REPAIR CATEGORY A MAJOR REPAIR, IAW FEDEX GSDR ABXR2020091500101Failsafe · crackedLOWER 2 BOLT HOLES CRACKED ON RT FAIL SAFE STRAP. PERFORMED FAIL SAFE STRAP CUT OUT, IAW SB 53-A0100 AND ATLAS EO NR 6753A070.SDR ABXR2020091500100Failsafe · crackedLOWER FASTENER HOLE CRACKED ON LEFT FAIL SAFE STRAP STA 955. PERFORMED CUT OUT ON FAIL SAFE STRAP, IAW SB 53-A0100 FIG 15 AND ATLAS EO NR 6753A070.SDR 2020F00398Frame · crackedNLG MID FRAME CRACK. ACCOMPLISHED NETJETS RFTS-104151 REV 0 DATED 03SEP20; N361QS (S/N 680-0235) NLG MID FRAME CRACK PERMANENT REPAIR.SDR EBVR20200915001Structure · corrodedFOUND DURING CABIN INTERNAL ZONAL INSPECTION, FOUND SEVERAL SPOTS OF CORROSION ON STRUCTURE UNDER THE CENTER DROP AISLE PANELS. PERFORMED AQRD REPAIR ERO-966932 REVISION A DATED SEP 10 2020 AT FUSELAGE FLOOR F.S. 157.SDR SWAA2020100620397Pressure Deck · dentedFLIGHT DECK FLOOR IS DENTED AT BS 255; RBL 4-LBL 14; WL 207.54. THE DAMAGE IS REPAIRED, PER EA 1-A53-33179 REV 1 WITH A CONCURRENT REPAIR NOTED IN EA 20-153-01899 REV IR NRC U251986 AND ER 20-03288 REV IR.SDR AALA202009229016Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON LEFT HAND AFT PASSENGER/CREW DOOR CUT OUT LOWER SILL CENTER FITTING AT FR 67 AND S23L. REPLACED CENTER FITTING, PER SRM 51-72-11.SDR SWAA2020091716279Door Frame · damagedDAMAGE FOUND ON L1 DOOR LOWER HINGE CUTOUT. PERFORMED CUTOUT OF DAMAGE AT L1 DOOR LOWER HINGE, PER EA 20-152-01734 PART 1 142987.SDR ABXR2020091400089Structure · crackedNWW RIGHT HAND STA 287 RBL 25 VERT CHORD CRACKED NEXT TO FASTENER HEAD. REPAIR CHORD IAW BOEING 767 SRM, IAW BOEING 767 SRM 51-70-12 FIG 1 SHEET 1-7. SEE PARTIAL WORK ACCOMPLISHED AND PARTIAL SHEET 10 AND BOEING DRAWING 141T2938.SDR SWIA202052788Support Rod · crackedFUELING PANEL SUPPORT ROD IS CRACKED AND GOUGED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED FUEL PANEL SUPPORT ROD, REF E175 AMM.SDR SWIA202052787Rib · crackedPANEL 345 AR INNER RIB CRACKED, AS MARKED. C-CHECK RO 9/24/2020. REMOVED AND REPLACED CRACKED RIB ON PANEL 345AR, REF EMB SRM.SDR DALA2020091603088Strap · corrodedCORROSION LEVEL 2, DURING INSPECTION CORROSION WAS FOUND ON FLOOR STRUCTURE STRAP 1681 BL-0. REPLACED GUSSET PLATE AT STA 1681 BL-0, PER SRM.SDR SWIA202053385Door Frame · corrodedPASSENGER DOOR SURROUND STRUCTURE: LOWER SILL ANGLE IS CORRODED. C-CHECK RO 10/16/2020. PASSENGER DOOR SURROUND STUCTURE: LOWER SILL ANGLE REPLACED, REF CRJ700 SRM AND DWG. M-337 AND SKYWEST TASK CARD COMPLIED WITH.SDR SWIA202053331Crossbeam · crackedAFT EQUIP BAY RT ACM SUPPORT STRUCTURE LATERAL CROSS BRACE AT APPROXIMATELY FS 711.0 AND BL 13 RT HAS EVIDENCE OF CRACK. C-CHECK RO 10/13/2020. REPLACED CRACKED SUPPORT CROSS BEAM ON RT ACM SUPPORT STRUCTURES WITH NEW PN 601R95159-35 PO T- 56457, REF CRJ 200SDR AALA202009159001Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED PRESSURE DECK PANEL LEFT HAND INBOARD FASTENER HOLE AT FR 35 AND S26L. REPAIRED PRESSURE DECK PANEL, PER EO 5316Y209.SDR SWIA202053503Gusset · corrodedPAX DOOR SURROUND STRUCTURE GUSSET CORRODED AT FS 349 AT STGR 15L. C-CHECK RO 10/18/2020. REMOVE AND REPLACED PAX DOOR SURROUND STRUCTURE GUSSET AT FS 349 AT STR 15L, IAW CRJ SRM.SDR SWIA202053502Gusset · corrodedPAX DOOR SURROUND STRUCTURE GUSSET CORRODED BETWEEN STGR 15L AND STGR 16L AT FS 310. C-CHECK RO 10/18/2020. REMOVED AND REPLACED GUSSET, IAW CRJ 200 SRM. REFER TO CONTINUE CARD FOR WORK PERFORMED.SDR SWIA202053381Door Frame · corrodedPAX DOOR FRAME FS 320.00 HAS CORROSION. C-CHECK RO 10/16/2020. REPLACED PAX DOOR FRAME AT FS 320.00, AS PER CRJ 700 SRM AND DRAWING M-337 AND SKYWEST TASK CARD COMPLIED WITH.
Back to JASC 5310