What was found
INSPECTION TYPE: 2C FWD CARGO AFT BULKHEAD AT STA 6-70 LT THE 5TH VERTICAL BEAM HAS CORROSION. REMOVED, FABRICATED, AND INSTALLED VERTICAL STANCHION AT STA Y=6.73 AND X= -9.05 BETWEEN Z= -19 AND Z= -117, IAW DWG AGA7094 (MINOR).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: 2C FWD CARGO AFT BULKHEAD AT STA 6-70 LT THE 5TH VERTICAL BEAM HAS CORROSION. REMOVED, FABRICATED, AND INSTALLED VERTICAL STANCHION AT STA Y=6.73 AND X= -9.05 BETWEEN Z= -19 AND Z= -117, IAW DWG AGA7094 (MINOR).