JASC 5310
Service difficulty reports · 38,528
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020082407147Floor Skin · damagedFLIGHT DECK FLOOR DAMAGE AT STA 260; REPAIR PER EA. / REMOVED FASTENERS ON REPAIR AREA PER REF. B737-700 SRM 51-40-02-0G-0 AND EA NO: 1-A53-53179 REV 1. TRIM OUT DAMAGED SECTION AT FLIGHT DECK FLOOR BS 260 PER REF. EA NO: 1-A53-33179 REV. 1. PERFORMED HFEC AT SDR SWAA2020082708844Floor Skin · dentedCOCKPIT FLOOR UNDER 2ND. OBSERVER SEAT APPROX. STA. 260 IS DENTED; WL 207.54; LBL 14 TO RBL ACCOMPLISHED PERMANENT REPAIR AT COCKPIT FLOOR WEB APPROX STA 260; WL 207.54 FROM LBL 20 TO RBL 5 PER EA 1-A53-33179 REV1 FIG.1.SDR AALA2020082439024Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF SILL BEAM AT R4 DOOR CUTOUT AT FR68 AND BL -Y1732, MEASURING L=1.1 IN, W=0.85 IN, D=0.071 IN. ACCOMPLISHED PERMANENT REINFORCING REPAIR WITH NESTED ANGLES IAW SRM 53-41-14-300-001 AND EA 307839.SDR AALA202008189014Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF DOOR 4L SILL BEAM BETWEEN FR67 AND FR68 AT BL Y1732, MEASURING L=1.5 IN, W=0.8 IN, D=0.05 IN. ACCOMPLISHED PERMANENT REINFORCING REPAIR WITH ANGLE AND FILLER IAW A321 SRM 53-41-14-300-001.SDR EBVR20200807001Structure · corrodedCORROSION FOUND AROUND THREE LOCK FASTENERS IN CENTER AFT CABIN FLOOR JUST FWD OF OUTFLOW VALVES, FOUND SEVERAL SPOTS OF CORROSION ON STRUCTURE UNDER THE CENTER DROP AISLE PANELS. FINAL REPAIR ERO-966682 REV IR AND 8110-3. VERTICAL REAR SPAR INSPECTION FOUND SDR SWIA202052562Skin · dented1 SMOOTH DENT IN PASSENGER DOOR OUTER SKIN APROX 16" AF OF LEADING EDGE AND 12" FORM TOP. IF WITHIN ACCEPTABLE LIMITS OR REWORKED ELIMINATE EVIDENCE USING STANDARD PRACTICES. C-CHECK RO 9/20/2020. REPAIRED PAX DOOR EXTERNAL SKIN DENT PER REO. SEE CONTINUASDR SWIA2020090952362Stop Fitting · corrodedPASSENGER DOOR LOWER STOP FITTING CORRODED, MARKED. C-CHECK RO 9/5/2020. REMOVED AND REPLACED CORRODED PASSENGER DOOR LOWER STOP FITTING WITH NEW (P/N 601R38923-3) USING NEW FASTENERS, REF CRJ700 AMM'S. ALL CHECKS GOOD,SDR AALA202008109020Coupling · damagedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLE IN SPLICE COUPLING AT FR66 AND STR 23R. REWORKED FASTENER HOLE IAW A321 SRM 51-72-11-911-001, SRM 51-42-11-801, AND DRAWING D5347015.SDR AALA202008079008Stop Fitting · wornAIRCRAFT IN BASE MAINTENANCE - R2 AFT GALLEY, 3 EACH FORWARD DOOR STOPS WORN (5, 6, 7). REPLACED 3 EACH DOOR STOP FITTING PER AMM TASK 52-13 -31-400-002-A.SDR FDEA2020080761777Support Beam · crackedFWD CARGO DOOR ACTUATOR SUPPORT BEAM BETWEEN FR22-FR23 FOUND CRACKS AS MARKED. FWD CARGO DOOR ACTUATOR SUPPORT BEAM BETWEEN FR22-FR23 FOUND CRACKS AS MARKED. REPLACED THE CRACKED DOOR ACTUATOR SUPPORT BEAM ON FWD CARGO BETWEEN FR22-FR23 PER A300-600F SRMSDR FDEA2020080761776Support Beam · crackedAFT CARGO DOOR ACTUATOR SUPPORT BEAM BETWEEN FR61-FR62 FOUND CRACKED. REPLACED THE AFT CARGO DOOR ACTUATOR SUPPORT BEAM IAW SRM 51-40-21. THIS REPAIR CATEGORY IS A. MAJOR REPAIR IAW GMM 6-2-100.SDR SWAA2020090407290Beam · corrodedCORROSION AT COCKPIT ON FWD SIDE OF BS270 LATERAL BEAM LBL11 - RBL11 WL208. MARKED/REPAIRED BS270 LATERAL BEAN LBL11-RBL11; WL208 PER EA 1-A53-13812 REV.2.SDR SWIA202081951824Doubler · corrodedCORROSION - LH COCKPIT FLOOR DOUBLER CORRODED FR 12-8 /. COMPLIED WITH ETD FOR PERMANENT REPAIR/REMOVAL OF CORROSION ON LH COCKPIT FLOOR DOUBLER BETWEEN FRAME 8 THROUGH 12. THIS REPAIR DOES NOT ADVERSELY AFFECT A FATIGUE CRITICAL STRUCTURE AND DOES NOT REPSDR DALA2020080602728Stop Fitting · crackedCRACK INDICATION ON PASSENGER CREW DOOR FRAME 16, RT. DOOR STOP FITTING NR 7, FASTENER HOLE 1. PERFORMED REPAIR ON THE DOOR FRAME STOP FITTING IAW ERA 587282-14AD.SDR SWIA2020091652558Gusset · gougedGUSSET FOR FRAME AT APPROX FS 559+48 AND APPROX STGR 6R IS GOUGED, FLAGGED. C-CHECK RO 9/12/2020. FOUND DAMAGES ON OVERHEAD BIN DRAG LINK GUSSET AT FRAME AT APPROX FS 559+48 AND APPROX STGR 6R OUT OF LIMIT WITH 100% MATERIAL LOSS. REPLACED GUSSET WITH NEW FSDR IPXA2020082649447Door Frame · crackedINSPECTION TYPE:2CCENTER LANDING L/H GEAR DOOR FWD. FRAME IS CRACKED.REMOVED AND REPLACED FRAME IAW SRM 51-35-01. (MINOR)SDR SWIA202081751823Crossbeam · corrodedFWD FUSELAGE- CORROSION- RH CROSSBEAM AT FR 17 HAS CORROSION O/B OF RH CENTER SEAT TRACK. CUT OUT DAMAGE , FABRICATED AND INSTALLED REPAIR PARTS ON CROSSBEAM FR17 PER SRM. REFER TO CONTINUATION CARD FOR WORK PERFORMEDSDR IPXA2020081769107Beam · crackedINSPECTION TYPE:2C, R-3 DOOR PLUG UPPER BEAM IS CRACKED AT THE FWD. END. REMOVED AND REPLACED DOOR BEAM IAW SRM 51-33-01 & 51-35-01. (MINOR).SDR IPXA2020081769106Beam · crackedINSPECTION TYPE:2C, L-3 DOOR PLUG LOWER BEAM IS CRACKED AT THE FWD END. REMOVED AND REPLACED DOOR BEAM IAW SRM 51-33-01 & 51-35-01. (MINOR)SDR AALA202008139011Seat Track · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF SEAT TRACK AT FR20 AND BL -Y1292, MEASURING L=1.580 IN, W=0.340 IN, D= 0.008 IN. REPLACED SEAT TRACK WITH MODIFIED PART IAW A321 SRM 51-72-11-911-001 AND DRAWINGS D53110920, D53110984, AND D53918124.SDR DALA2020080632725Stiffener · crackedCRACK INDICATION ON FRAME 4 RT WINDSHIELD SIDE POST LOWER ATTACHMENT, INTEGRATED STIFFENER AT THE TOP OF THE FLANGE . CRACK LENGTH 0.250 INCH. PERFORMED A REPAIR IAW CARD 5311-01230-01B.SDR IPXA2020082649448Door Frame · crackedINSPECTION TYPE:2CCENTER LANDING GEAR R/H DOOR FWD. FRAME IS CRACKED.REMOVED AND REPLACED FRAME IAW SRM 51-35-01. (MINOR)SDR DALA2020080632724Pressure Plate · crackedCRACKED FRAME 36 THAT DOES NOT EXCEED THE AUTHORIZED REPAIR AREA WAS FOU PERFORMED REPAIR ON FRAME 35 TO FRAME 36 LH PRESSURE PLATE AREA AS PER WORK CARD 5311-01171-04A. AND AT THE PRESSURE PLATE AREA BETWEEN FRAMES 35 & 36. PERFORMED A REPAIR IAW WORK CARD 5SDR FDEA2020080321748Stop Fitting · crackedMAIN DECK CARGO COMPARTMENT R3 DOOR, NR 5 BEAM, FORWARD DOOR STOP NR 5 WAS FOUND CRACKED.SDR SWIA2020090452253Door Frame · corrodedTHE PASSENGER DOOR FORMER AT FS311.75 AT DD5 HAS CORROSION. REMOVED AND INSTALLED NEW PASSENGER DOOR FWD FORMER AT FS311.75 IAW SRM AND DWG.SDR DALA2020080622723Stiffener · crackedCRACK INDICATION ON FRAME 4 WINDSHIELD SIDE POST LOWER ATTACHMENT RT SIDE VERTICAL STIFFENER. PERFORMED A REPAIR ON FRAME 4 R/H WINDSHIELD SIDE POST LOWER ATTACHMENT VERTICAL STIFFENER IAW CARD 5311-01230-01B.SDR DALA2022111507362Door Frame · damagedSHIP 3232 ER/A 587207-14AD ISSUED FOR LH FR68 WEB AT DOOR STOP 1 CRACK INSPECTION. CORRECTIVE ACTION: COMPLIED WITH ERA 587207-14AD. (1587429)SDR DALA2022111507359Web · crackedSHIP 3232 ER/A 587207-14AD ISSUED FOR LH FR68 WEB AT STOP 1 CRACK INSPECTION. CORRECTIVE ACTION: COMPLIED WITH ERA 587207-14AD REV A. (1587431)SDR SWIA2020091652506Fitting · crackedRT WINDSHIELD SIDE POST LOWER AFT CLIP IS CRACKED. C-CHECK RO 9/12/2020. REMOVED AND REPLACED RT WINDSHIELD SIDE POST LOWER AFT CLIP, REF CRJ 200 SRM & BOMBARDIER DRAWING. REMOVED 0.12 POUNDS THEN INSTALLED 0.12 POUNDS, NO WEIGHT CHANGE. TUC1755 CAL DUE: 3SDR SWIA2020091652505Fitting · crackedLT WINDSHIELD SIDE POST LOWER AFT CLIP IS CRACKED. C-CHECK RO 9/12/2020. REMOVED AND REPLACED LT WINDSHIELD SIDE POST LOWER AFT CLIP, REF CRJ 200 SRM & BOMBARDIER DRAWING. COMPLIED WITH TASK CARD.SDR SWIA2020082151964Splice · corrodedCORROSION ON RH FLOOR BEAM SPLICE AT FR 90 . REMOVED AND REPLAED R/H FLOOR BEAM SPLICE AT FR 90 REF SRM,SDR SWIA2020082151963Splice · corrodedCORROSION ON SPLICE BETWEEN RH FLOOR BEAM TO INTERCOASTAL AT FR89. REMOVED AND REPLACED SPLICE BETWEEN RH FLOOR BEAM TO INTERCOASTAL AT FR89 REF SRMSDR SWIA202081751810Beam · corrodedCORROSION IN R/H BEAM FR.89-90. REMOVED AND REPLACED R/H BEAM BETWEEN FR.89-90 PER SRMSDR SWIA202081751809Beam · corrodedCORROSION IN R/H BEAM FR.86-89. REMOVED AND REPLACED R/H BEAM FR.86-89 AND RESTORED TOPCOAT TO NEW INSTALLATION. PER SRMSDR SWIA2020081251781Splice · corrodedCORROSION FOUND ON I/B TOP SPLICE FOR RBL9 AT FS572.00. REPLACED IB TOP SPLICE ON RBL9 FLOORBEAM AT FS572.00 PER SRM, AND DWGS.SDR SWIA2020081251780Splice · corrodedCORROSION ON RBL9 SPLICE AT FS 686 IB AND OB TOP SPLICE. REPLACED IB & OB TOP SPLICE AT RBL9 FLOORBEAM, FS686 PER SRM, BOMBARDIER DWG AND BOMBARDIER DWG. COMPLIED WITH SKYWEST TASKCARDSDR SWIA2020081251779Splice · corrodedCORROSION FOUND ON OB TOP SPLICE FOR RBL9 AT FS572.00. REPLACED OB TOP SPLICE FOR RBL9 FS572.00 IAW SRM, AND DWGS.SDR KCSA202007301132Structure · corrodedCORROSON FOUND AT B STA 1480 BWL 91 LBL 80SDR SWIA202053894Screw · damagedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA-REPAIRED DAMAGED SCREW HOLE 7 O' CLOCK POSITION, 3RD WINDOW AFT OF PAX DR, LT REF REO. SDIR-SPECIAL DETAILED-SEE NOTE (1), METHOD TBD, PART NUMBER: -, SERIAL NUMBER: 7843, POSITION: C-CHECK RO 11/11/2020. COMPLIED WSDR 2020F00351Doubler · crackedCRACK DAMAGE, NOSE LANDING GEAR WHEEL WELL (NWW), FRAME, WEB, AND DOUBLERS, FS 75. ACCOMPLISHED TEXTRON AVIATION FIELD REPAIR SR-680A-ATA53-25890 REV- DATED JUNE 1, 2020 AND 8100-9 DATED 6/1/2020; STANDARD REPAIR - CRACK DAMAGE, NOSE LANDING GEAR WHEEL WELL (NSDR SWIA2020090452233Beam · corrodedTHE BEAM CAP AT LBL9.00 BETWEEN APPROX FS589.00 AND FS621.00 HAS MULTIPLE LOCATIONS OF CORROSION (MARKED). C-CHECK RO 9/1/2020. THE BEAM CAP AT LBL9.00 BETWEEN APPROX FS589.00 AND FS621.00 REPLACED REF REO AND DRAWING. SEE CONTINUATION CARD FOR DETAILS.SDR FDEA2020080581769Web · crackedCLG WHEEL WELL SIDE WALL HAS A CRACK IN THE AFT LEFT CORNER. REPAIRED CLG WHEEL WELL SIDE WALL CRACK IN ACCORDANCE WITH EA 8-5330-T0355551. INSTALLED REPAIR DOUBLER.SDR SWIA2020090452227Door Frame · corrodedMAIN AVIONICS COMPARTMENT DOOR CUTOUT INTERIOR SURROUND STRUCTURE FS364 GUSSET AT APPROX. STGR26R HAS CORROSION. C-CHECK RO 9/1/2020. BLENDED CORROSION, REFERENCE CRJ200 SRM. BEYOND ALLOWABLE LIMITS REF. CRJ200 SRM. REMOVED AND REPLACED GUSSET P/N: 601R310SDR SWIA2020090452217Pressure Panel · corrodedLT PRESSURE FS PANEL HAS SEVERAL AREAS OF CORROSION. C-CHECK RO 9/1/2020. REMOVED CORROSION FROM LT PRESSURE FS PANEL REF CRJ 200 SRM. BLENDED AREA FOUND TO BE WITHIN LIMITS REF REO. SEE CONTINUATION CARD FOR DETAILS.SDR 6PMR2020082900407Pressure Deck · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N590 DISCREPANCY: RMWW UPPER PRESSURE DECK WEB HAS CORROSION ARROUND FASTENERS AT STA 1074 ABD RBL 60. CORRECTIVE ACTION: REMOVED CORROSION ON RT WW PRESSURE DECK, AREA FOUND TO BE ACCEPTABLE AS IS. TREATED AND PRIMED IAW EO 20SDR 6PMR2020082600382Pressure Web · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N592 DISCREPANCY: LMWW UPPER PRESSURE DECK WEB HAS CORROSION AT STA 1120 TO 1180 AND BL0 TO LBL 24.75. CORRECTIVE ACTION: EVALUATED UPPER PRESSURE DECK WEB AT STA 112-1180 LBL 0 TO LBL 24.75, ALL (21) AREAS FOUND TO BE ACCEPTABLSDR 6PMR2020082600379Pressure Deck · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N591 DISCREPANCY: LMWW UPPER PRESSURE DECK WEB HAS CORROSION AROUND FASTENERS AT STA 1120 FROM BL 0 TO LBL 70. CORRECTIVE ACTION: EVALUATED UPPER PRESSURE DECK WEB AT STA 1120 LBL 0 TO LBL 70, ALL (21) AREAS FOUND TO BE ACCEPATASDR SWAA2020082510159Floor Skin · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. / DAMAGE REPAIRED PER EA 1-A53-33179 REV 1.SDR YENA2020080300409Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43 (2 EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA LH SIDE; (REF ARM W/O 2020-230/1 N/R 2020-211471) PERFORMED PERMANENT REPAIR ON BEAM FR 43 LH SIDE IAW EC A320-1251.SDR YENA2020080300408Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43RH SIDE (2EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA; (REF ARM W/O 2020-230/1 N/R 2020-211473) PERFORMED PERMANENT REPAIR ON BEAM FR 43 RH SIDE IAW EC A320-1251.
Back to JASC 5310