JASC 5310
Service difficulty reports · 38,548
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2020082151964Splice · corrodedCORROSION ON RH FLOOR BEAM SPLICE AT FR 90 . REMOVED AND REPLAED R/H FLOOR BEAM SPLICE AT FR 90 REF SRM,SDR SWIA2020082151963Splice · corrodedCORROSION ON SPLICE BETWEEN RH FLOOR BEAM TO INTERCOASTAL AT FR89. REMOVED AND REPLACED SPLICE BETWEEN RH FLOOR BEAM TO INTERCOASTAL AT FR89 REF SRMSDR SWIA202081751810Beam · corrodedCORROSION IN R/H BEAM FR.89-90. REMOVED AND REPLACED R/H BEAM BETWEEN FR.89-90 PER SRMSDR SWIA202081751809Beam · corrodedCORROSION IN R/H BEAM FR.86-89. REMOVED AND REPLACED R/H BEAM FR.86-89 AND RESTORED TOPCOAT TO NEW INSTALLATION. PER SRMSDR SWIA2020081251781Splice · corrodedCORROSION FOUND ON I/B TOP SPLICE FOR RBL9 AT FS572.00. REPLACED IB TOP SPLICE ON RBL9 FLOORBEAM AT FS572.00 PER SRM, AND DWGS.SDR SWIA2020081251780Splice · corrodedCORROSION ON RBL9 SPLICE AT FS 686 IB AND OB TOP SPLICE. REPLACED IB & OB TOP SPLICE AT RBL9 FLOORBEAM, FS686 PER SRM, BOMBARDIER DWG AND BOMBARDIER DWG. COMPLIED WITH SKYWEST TASKCARDSDR SWIA2020081251779Splice · corrodedCORROSION FOUND ON OB TOP SPLICE FOR RBL9 AT FS572.00. REPLACED OB TOP SPLICE FOR RBL9 FS572.00 IAW SRM, AND DWGS.SDR KCSA202007301132Structure · corrodedCORROSON FOUND AT B STA 1480 BWL 91 LBL 80SDR SWIA202053894Screw · damagedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA-REPAIRED DAMAGED SCREW HOLE 7 O' CLOCK POSITION, 3RD WINDOW AFT OF PAX DR, LT REF REO. SDIR-SPECIAL DETAILED-SEE NOTE (1), METHOD TBD, PART NUMBER: -, SERIAL NUMBER: 7843, POSITION: C-CHECK RO 11/11/2020. COMPLIED WSDR 2020F00351Doubler · crackedCRACK DAMAGE, NOSE LANDING GEAR WHEEL WELL (NWW), FRAME, WEB, AND DOUBLERS, FS 75. ACCOMPLISHED TEXTRON AVIATION FIELD REPAIR SR-680A-ATA53-25890 REV- DATED JUNE 1, 2020 AND 8100-9 DATED 6/1/2020; STANDARD REPAIR - CRACK DAMAGE, NOSE LANDING GEAR WHEEL WELL (NSDR SWIA2020090452233Beam · corrodedTHE BEAM CAP AT LBL9.00 BETWEEN APPROX FS589.00 AND FS621.00 HAS MULTIPLE LOCATIONS OF CORROSION (MARKED). C-CHECK RO 9/1/2020. THE BEAM CAP AT LBL9.00 BETWEEN APPROX FS589.00 AND FS621.00 REPLACED REF REO AND DRAWING. SEE CONTINUATION CARD FOR DETAILS.SDR FDEA2020080581769Web · crackedCLG WHEEL WELL SIDE WALL HAS A CRACK IN THE AFT LEFT CORNER. REPAIRED CLG WHEEL WELL SIDE WALL CRACK IN ACCORDANCE WITH EA 8-5330-T0355551. INSTALLED REPAIR DOUBLER.SDR SWIA2020090452227Door Frame · corrodedMAIN AVIONICS COMPARTMENT DOOR CUTOUT INTERIOR SURROUND STRUCTURE FS364 GUSSET AT APPROX. STGR26R HAS CORROSION. C-CHECK RO 9/1/2020. BLENDED CORROSION, REFERENCE CRJ200 SRM. BEYOND ALLOWABLE LIMITS REF. CRJ200 SRM. REMOVED AND REPLACED GUSSET P/N: 601R310SDR SWIA2020090452217Pressure Panel · corrodedLT PRESSURE FS PANEL HAS SEVERAL AREAS OF CORROSION. C-CHECK RO 9/1/2020. REMOVED CORROSION FROM LT PRESSURE FS PANEL REF CRJ 200 SRM. BLENDED AREA FOUND TO BE WITHIN LIMITS REF REO. SEE CONTINUATION CARD FOR DETAILS.SDR 6PMR2020082900407Pressure Deck · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N590 DISCREPANCY: RMWW UPPER PRESSURE DECK WEB HAS CORROSION ARROUND FASTENERS AT STA 1074 ABD RBL 60. CORRECTIVE ACTION: REMOVED CORROSION ON RT WW PRESSURE DECK, AREA FOUND TO BE ACCEPTABLE AS IS. TREATED AND PRIMED IAW EO 20SDR 6PMR2020082600382Pressure Web · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N592 DISCREPANCY: LMWW UPPER PRESSURE DECK WEB HAS CORROSION AT STA 1120 TO 1180 AND BL0 TO LBL 24.75. CORRECTIVE ACTION: EVALUATED UPPER PRESSURE DECK WEB AT STA 112-1180 LBL 0 TO LBL 24.75, ALL (21) AREAS FOUND TO BE ACCEPTABLSDR 6PMR2020082600379Pressure Deck · corrodedAIRBORNE/PEMCO NON-ROUTINE 2867N591 DISCREPANCY: LMWW UPPER PRESSURE DECK WEB HAS CORROSION AROUND FASTENERS AT STA 1120 FROM BL 0 TO LBL 70. CORRECTIVE ACTION: EVALUATED UPPER PRESSURE DECK WEB AT STA 1120 LBL 0 TO LBL 70, ALL (21) AREAS FOUND TO BE ACCEPATASDR SWAA2020082510159Floor Skin · dentedFLIGHT DECK FLOOR IS DENTED AT B.S. 255; R.B.L. 4 - L.B.L. 14; W.L. 207.54. / DAMAGE REPAIRED PER EA 1-A53-33179 REV 1.SDR YENA2020080300409Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43 (2 EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA LH SIDE; (REF ARM W/O 2020-230/1 N/R 2020-211471) PERFORMED PERMANENT REPAIR ON BEAM FR 43 LH SIDE IAW EC A320-1251.SDR YENA2020080300408Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43RH SIDE (2EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA; (REF ARM W/O 2020-230/1 N/R 2020-211473) PERFORMED PERMANENT REPAIR ON BEAM FR 43 RH SIDE IAW EC A320-1251.SDR MASA20200727057Crossbeam · corrodedFS280 CROSS BEAM CORRODED. REPAIRED IAW SB670BA-53-041.SDR DALA2021052102836Door Frame · damagedON WALKAROUND, FOUND DAMAGE TO AFT CARGO DOOR JAMB, AFT SIDE. REMOVED EXISTING DAMAGE PER PRI 587222-14, REV 0, STEPS 1 THROUGH 5. COMPLETED STEPS 6 THROUGH 10 OF R.I. ASSOCIATED ER/A 587222-14 ADDED FOR AC 9550. COMPLIED WITH ER/A 587222-14 REV. C. SECTION V SDR SWIA2020090952392Crossbeam · corrodedFS 280 CROSSBEAM AND FWD J ANGLE ARE CORRODED LBL 19 TO RBL 27. C-CHECK RO 9/5/2020. REPAIRED FS 280 CROSSBEAM AND FWD J ANGLE, IAW REO CRJ-200 SRM. TASK CARD COMPLIED WITH, M-337 ATTACHED. WEIGHT AND BALANCE NOT AFFECTED.SDR SWAA2020082503348Pressure Panel · cracked2 CRACKS FOUND ON HORIZONTAL PRESSURE WEB AT RBL 42 AND RBL 43 AT STA663. / ACCOMPLSIHED HORIZONTAL PRESSURE WEB REPAIR AT RT SIDE STA 663 BETWEEN RBL 40' TO RBL 60' REF B737-700 SRM 53-40-51-2R-2 DETAIL (A) FIG 202.SDR SWAA2020081708478Floor Skin · dentedFLIGHT COMPARTMENT FLOOR HAS SEVERAL AREAS OF BARE METAL. / DENTED BARE METAL AREAS REMOVED AND REPAIRED IAW EA 1-A53-33179 REV 1.SDR SWAA2021081803621Fitting · corroded***CORROSION*** ON STRINGER END FITTING AT AREA AFT OF ACB BS1011 LBL9 WL187. MARKED / CORROSION ON STRINGER END FITTING BS1011 LBL9 WL187 FOUND TO BE OUT OF LIMITS DUE TO NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM. REMOVED DAMAGED END FITTING; RECEIVED NEW FITTISDR SWIA2020090952366Fitting · crackedCOCKPIT WINDOW LT SIDE POST LOWER FITTING CRACKED AT WL 110.00. C-CHECK RO 9/5/2020. REMOVED LT SIDE POST LOWER FITTING AT WL 110.00. LOCATED, DRILLED, AND INSTALLED NEW SERVICEABLE LT SIDE POST LOWER FITTING IAW SRM.SDR SWIA2020090252172Buttstrap · corrodedCORROSION FOUND ON BUTT STRAP AT F.S. 333 STRINGER 27-26L. C-CHECK RO 8/29/2020. REMOVED AND INSTALLED NEW BUTT STRAP IAW CRJ 200 SRM AND BOMBARDIER DWG. COMPLIED WITH TASK CARD, M-337 COMPLETED. WEIGHT AND BALANCE NOT AFFECTED.SDR SWAA2020082503143Floor Skin · damagedFLIGHT DECK FLOOR DAMAGED / ACCOMPLISHED REPAIR AT FLIGHT COMPARTMENT FLOOR BS 260 AS PER EA 1-A53-33179 REV 1 .SDR SWIA2020081251777Frame Angle · crackedCLIP CRACKED COMMON TO FS333 FRAME AND WATER DRAIN MAST CHANNEL STGR 25R-24R. REMOVED CRACKED AND INSTALLED NEW CLIP REF. DWG AND SRM.SDR AALA202007319009Pressure Deck · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PRESSURE DECK OF OF RH UPPER WHEEL WELL AT STA 663 BETWEEN RBL 40 AND RBL 45, MEASURING L=0.6 IN, W=0.3 IN, D=0.4 IN. ACCOMPLISHED PERMANENT REINFORCING DOUBLER REPAIR IAW SRM 57-10-10-2R-3.SDR KCSA202007221127Stop Fitting · crackedR3 DOOR FWD FRAME STOP FITTING CRACKED.SDR SWIA2020090452207Window Post · crackedRT WINDSHIELD SIDE POST LOWER OUTBOARD CLIP CRACKED. C-CHECK RO 9/1/2020. REMOVED RT WINDSHIELD SIDE POST LOWER OUTBOARD CLIP (FITTING), REF CRJ200 SRM & INSTALLED NEW CLIP (FITTING) AT RT WINDSHIELD SIDE POST LOWER OUTBOARD, REF CRJ200 SRM AND BOMBARDIER DWSDR SWAA2020081002532Floor Skin · damagedFLIGHT DECK FLOOR WEB DAMAGE AT BS 260 / TRIMED OUT DAMAGE SECTION AT FLIGHT DECK FLOOR WEB BS 260 PER REF. EA NO 1-A53-33179 REV 1. FABRICATED REPAIR PARTS REPLACEMENT WEB; - 2 DOUBLER; -3 DOUBLER AND INSTALLED REPAIR PARTS PER REF. EA 1-A53-33179 REV 1 FOR DSDR SWAA2020072702304Crease Beam · corrodedR1 DOOR LOWER CUTOUT AREA CREASE BEAM INNER CHORD UPPER SURFACE CORRODED STA 312+12'; RBL60; WL 208. REMOVED AND INSTALLED NEW CREASE BEAM - INNER CHORD AT R-1 DOOR LOWER CUT OUT FROM STA 277 TO STA 360 REB 60 WL 208.0 IAW B737-700 SRM 51-40-02-0G-0 / 51-40-SDR SIMA202007221003Door Frame · corrodedCARGO DOOR CUTOUT AT FR 65 CORRODED AROUND NUTPLATE BETWEEN STGR 13L-14L. PERFORMED PERMANENT REPAIR ON CARGO DOOR CUTOUT AT FR 65 BETWEEN STGR 13L-14L IAW ERS-EM-53MR-4139.SDR AALA2020081869008Cover · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF AFT CARGO DOOR THRESHOLD TORSION BOX COVER SHEET IN PREVIOUSLY BLENDED AREA AT FR56R+11" AND STR 37R, MEASURING L=0.8 IN, W=0.6 IN, D=0.015 IN. COVER SHEET REPLACED WITH NEW IAW SRM 51-72-11-911.SDR FDEA202007201585Crossbeam · crackedCROSSBEAM ON NLG FR15A WEB FACE AT ATTACHMENT FITTING OF RACK 107VU FOUND CRACKED. CROSSBEAM ON NLG FR15A WEB FACE AT ATTACHMENT FITTING OF RACK 107VU FOUND CRACK. COMPLY WITH EA:6-5310-T0355184 P1. MAJOR REPAIR IAW GMM6-2-100.SDR QMLA2020072320037Deck Plate · crackedACFT WAS FOUND TO HAVE A 1.25" LONG CRACK ON THE TRANSMISSION DECK AT THE AFT RIGHT CORNER OF THE OPENING. THIS AIRCRAFT IS OUT OF SERVICE.SDR HNAA2020072000197Door Frame · bentHEAVY CHECK - CARGO DOOR AFT FRAME BENT AT LOWER END...REMOVED BENT CARGO DOOR LOWER AFT FRAME
CONTINUOUS STOP AND INSTALLED SERVICEABLE CONTINUOUS STOP IAW EMB 145 SRM 51-40-02.SDR FDEA2020080791774Web · crackedCRACKS AT NLG WHEEL WELL LT FWD UPPER BULKHEAD ON UPPER CAP AREA BEHIND THE HYD LINES AT APPROX STA 490. REPAIRED IAW SRM 53-30-00, VOL 1, FIG 6, SHEET 2, PAGE 18.SDR FDEA2020081871926Roller Track · corrodedCORROSION ROLLER TRACK ASSY BETWEEN FRAMES 32 TO 38.2, Y450 TO Y953 IN THE FWD CARGO COMPARTMENT. REPLACED THE ROLLER TRACK ASSY IAW SRM 51-72-10, AND DRAWING A25771363.SDR FDEA2020081871924Roller Track · corrodedCORROSION ROLLER TRACK ASSY LOC. AT FR37 AND BTW Y0 TO -Y453 IN FWD CARGO COMPARTMENT REPLACED ROLLER TRACK ASSY IN FWD CARGO IAW SRM 51-72-10 AND DRAWING A25774009.SDR FDEA2020081871923Roller Track · corrodedCORRODED ROLLER TRACK ASSY BETWEEN FRAMES 32 & 38.2, -Y450 TO -Y953 IN THE FWD CARGO COMPARTMENT. REPLACED THE ROLLER TRACK ASSY IAW SRM 51-72-10, AND DRAWING A25774009.SDR SWIA202008252051Door Frame · corroded* A BAY DOOR STRUCTURE - FS 349 - STGR 25R - FRAME CORRODED AFT OTBD QUAD . REMOVED AND REPLACED NEW FS 349.00 LOWER SECTOR P/N SH670-31357-5S REF CRJ 700 SRM. COMPLIED WITH TASK CARD. LEAK CHECK GOODSDR FDEA202007171571Window Frame · chafedRIGHT FLIGHT DECK SLIDING WINDOW, INSPECTION OF PREVIOUS DAMAGE & REWORK IAW EA 6- 5300-167476 INDICATES ADDITIONAL DAMAGE EXISTS. REPAIR ACCOMPLISHED ON EA 6-5300-167476-A PART 3. CAT "B" REPAIR. MAJOR REPAIR.SDR FDEA202007171565Crease Beam · corrodedMAIN DECK, BS 765 RT INBD CREASE BEAM WAS CORRODED. REMOVED THE CORROSION IAW SRM 51-10-02. EVALUATED 100% MATERIAL LOSS, AND OUT OF LIMITS IAW SRM 53-30-13, FIG 101. REPAIRED THE CREASE BEAM IAW SRM 53-00-13-2R, REP 1, ALT 1.SDR FDEA202007171561Crease Beam · corrodedMAIN DECK BS 1600, LEFT SIDE INBD CREASE BEAM CORRODED. REMOVED THE CORROSION IAW SRM 51-10-02. EVALUATED 100% MATERIAL LOSS, OUT OF LIMITS IAW SRM 53-60-13-1A, FIG 101. REPAIRED THE CREASE BEAM IAW SRM 53-00-13-2R, REP 1, ALT 1.SDR SWAA2021080301088Doubler · corrodedAFT CARGO COMPARTMENT; FRAME; WL157; LBL21; BS747; CORRODED / AFT CARGO FRAME 747 LBL 21 CORRODED. BLENDED AND REMOVED CORROSION AND CHECKED WITH 10X MAG I/A/W 51-10-02-0G-0 SRM. 'OUT OF LIMITS' THICKNESS IS .063 MAT LOSS .010 REMAINING .053 I/A/W SRM 53-00-07SDR SWIA2020090452197Bracket · crackedD: EXTERNAL POWER SERVICE PANEL LOWER MOUNTING BRACKET HAS A 2" CRACK IN THE RADIUS OF THE BEND. REPAIR AT NEXT C CHECK C: MCI. C-CHECK RO 9/1/2020. REMOVED AND INSTALLED NEW EXTERNAL POWER SERVICE PANEL, REF CRJ-200 SRM, ENG. DWG. AND MHIRJ REO. SEE CONT
Back to JASC 5310