SDR SWIA2020012347964Bolt · chafedL/H AFT WINDSCREEN OTBD SHOOT BOLT CHAFED (C-CHECK) RO:1/22/2020REMOVED AND REPLACED LH AFT WINDSCREEN OB SHOOT BOLT REF E 175 AMM.SDR AALA2020011769011Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO DOOR CUT OUT BEAM BETWEEN FR 24 AND FR 27 AT S27R. REPLACED BEAM PER DRAWING 170-67080-433.SDR ASAA2020011541922Frame · crackedPOSSIBLE CRACK ON FRAME 867 BETWEEN STRINGERS 8R AND 9R. GROUNDED - YES. REPAIRED MADE TO FRAME 867 BETWEEN STR 8R AND 9R IAW ASA 700-53EA-25215.SDR SWIA2020030348947Beam · corroded*FS280.00 BEAM UPPER FLANGE IS CORRODED BETWEEN LBL9 & RBL9. (MARKED) (C-CHECK) RO 2/28/2020 REMOVED CORROSION FROM FS280.00 BEAM UPPER FLANGE BETWEEN LBL9 & RBL9 REF CRJ200 SRM, UPPER FLANGE FOUND TO BE OUT OF LIMITS, REF CRJ200 SRM AND BOMBARDIER REO, COSDR IPXA2020020351743Door Frame · crackedINSPECTION TYPE:2CL-3 DOOR JAMB LOWER AFT WEB IS CRACKED AGT STA. 1313 & Z=-15.REPAIRED CRACKED L-3 DOOR JAMB LOWER AFT WEB AT STA. 1313 & Z=-15 IAW SRM 53-40-15 REPAIR 3 FIG. 201. (MAJOR)SDR SWAA2020012210631Beam · crackedR1 DOOR NR 4 BEAM WAS CRACKED. R & R THE NR 4 BEAM IAW SRM & DWG.SDR DALA2020011700376Pressure Panel · crackedNR 448:FR35-36 RT PRESSURE PANEL- A CRACK THAT DOES NOT EXCEED THE REPAIR AREA WAS FOUND AT HOLE 6. MODIFY IN ACCORDANCE WITH WORK CARD 5311-01171-4B PRIOR TO FURTHER FLIGHT. AA5311- 01171, SB A320-53-1263 AND AD-2018-06-04.SDR SWAA2020011427306Crease Beam · corrodedRIGHT AFT SERVICE DOOR (R2) SILL CREASE BEAM; STA 960 - 987; RBL 54; WL 208; IS CORRODED. / BLENDED CORROSION AT R2 DOOR CREASE BEAM STA 960-987 RBL 54 WL 208; ORIGINAL THICKNESS .040'; REMAINING .063'; LOSS OF .017' FOUND OUT OF LIMITS IAW SRM 53-70-1A-1. REMSDR SWAA2021050607318Slider · debondedRIGHT HORIZONTAL STAB LOWER FWD SLIDING SEAL WEAR STRIPS DISBONDED. / R&R SLIDER PER S.R.M. 53-31-31SDR SWAA2021050607317Rub Strip · debondedLEFT HORIZONTAL STAB LOWER FWD SLIDING SEAL WEAR STRIPS DISBONDED. / R&R SLIDER PER S.R.M. 53-34-34SDR SWAA2021050505892Seal · damagedLEFT STAB UPPER AFT SLIDER SEAL DAMAGED / R & R SEAL PER SRM 51-40-02 & SOPM 20-50-01.SDR SWAA2020020541022Crease Beam · corrodedUPPER FLANGE OF INBOARD CREASE BEAM CHORD CORRODED BETWEEN BS. 893 TO BS. 1006, LBL 56. / R&R INNER CHORD IAW DWG & SRM.SDR R61A202001260077Crossbeam · cracked***AIRCRAFT IS IN HEAVY CHECK***FR 12 CROSSBEAM FWD SIDE, LBL 36, ANGLE FOUND CRACKED. REPLACED ANGLE IAW SRM 51-41-01.***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A202001260076Crossbeam · cracked***AIRCRAFT IS IN HEAVY CHECK***FR 12 CROSSBEAM FWD SIDE, BL 0, ANGLE FOUND CRACKED. REPLACED ANGLE IAW SRM 51-41-01.***AIRCRAFT REMAINS IN HEAVY CHECK***SDR SWAA2020012240680Crease Beam · corrodedR2 DOOR SILL CREASE BEAM CORRODED BETWEEN BS. 960 TO BS. 987, RBL 54. R&R CREASE BEAM IAW SRM AND DWG.SDR SWAA2021041527265Barrier · crackedPER CUSTOMER REQUEST L.C. L/H VAPOR BARRIER HAS EXISTING REPAIR THAT IS CRACKED & PEELING. / VAPOR BARRIER LH STA663 REPAIRED IAW SRM 51-70-04-2R-0SDR AALA202001159027Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FASTENER HOLE ON THE RIGHT HAND NR 3 FLIGHT DECK WINDOW FRAME AT THE LOWER CORNER AT BS 240 AND S11R. REPAIRED WINDOW POST PER EA 301485.SDR AALA202001159025Window Post · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FASTENER HOLE ON THE LEFT HAND NR 3 FLIGHT DECK WINDOW FRAME AT THE LOWER CORNER AT BS 240 AND S11L. REPAIRED WINDOW POST PER EA 301484.SDR C77A2020011400008Door Frame · corrodedTHIS EO PROVIDES INSTRUCTIONS TO COMPLY WITH PART I OF SB 170-53-0118, WHICH ACCOMPLISHES A MODIFICATION ON THE FORWARD CARGO DOOR SURROUNDING STRUCTURE. THIS MODIFICATION CONSISTS OF APPLYING CIC TO FASTENERS AND SURROUNDING STRUCTURE, APPLYING POLYURETHANE PSDR AALA2020020549036Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT HAND AFT DOOR CUT OUT LOWER CSILL CENTER FITTING BETWEEN FR 66 AND FR 68 AT S23L. REPLACED CENTER FITTING PER SRM 51-72-11.SDR SWIA2020013148031Pressure Deck · crackedCOMPLY WITH SCHEDULED MAINTENANCE CODE: RA - THE PRESSURE FLOOR SKIN AT FS 461.00 HAS TWO CRACKS 2 INCHES LONG ONE BTWN BL0.0 AND LBL9 AND 1 BTWN BL0.0 AND RBL9. REPAIRED PER REO PER NDT MANUAL, PART NUMBER: - , SERIAL NUMBER: 7578, POSITION: (C-CHECK) RSDR ASAA2020013022014Support Frame · corrodedAFT WET AREA RH LATERAL SUPPORT FRAME AT FR69-FR70 HAS CORROSION ON LOWER SIDE GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT IAW A319 SRM 51-42-11 REF AIRBUS DWG# D53474180. THIS IS A CATEGORY "A" REPAIR. (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM)SDR ASAA2020013022013Support Frame · corrodedAFT WET AREA LH LATERAL SUPPORT FRAME AT FR69-FR70 HAS CORROSION ON LOWER SIDE GROUNDED - YES. REMOVED AND REPLACED FRAME SUPPORT IAW A319 SRM 51-42-11 REF AIRBUS DWG D53474180. THIS IS A CATEGORY "A" REPAIR (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRM)SDR REXA2020012820064Striker · worn"INITIAL INSPECTION: WEAR ON LOWER STRIKER AT PASSENGER DOOR SURROUND STRUCTURE (W1)
"LOWER SEAL STRIKER WAS REPLACED FOR A NEW ONE PER CRJ-900 SRM 51-42-21-001-001-A01 PAR.6.C AND SRM 51-42-06-001-001-SDR RAIA2020012312008Web · crackedLH W/W REAR WEB IS CRACKED @ UPPER O/B CORNER- REMOVED DAMAGED LH W/W REAR WEB LOCATED AND DRILLED NEW LH W/W WEB. INSTALLED NEW LH W/W REAR WEB.SDR DALA2020011300224Door Frame · worn(LOG 1442404) DURING INSPECTION FOUND WORN WEB ON E/E RIGHT DOOR JAMB AT ELECTRICAL ELECTRONIC COMPARTMENT. WEB ON E/E DOOR JAMB (RH SIDE) WAS REPLACED PER. B737-800 SRM 53-10-15 FIG 3 AND B 737-800 S.R.M. 51-40-02.SDR SWIA2020030248878Beam · corrodedFS 280..00 BEAM IS CORRODED BETWEEN LBL 18 AND RBL 9. (C-CHECK) RO 2/27/2020 REMOVED CORROSION BY REPAIRING FS 280.00 BEAM IAW BOMBARDIER REOS. COMPLETED AND ATTACHED MAJOR REPAIR TASK CARD AND FORM M-337. TOTAL WEIGHT CHANGE +1.13 LBS. REFERENCE CONTINUATSDR ASAA2020012912009Floor Support · corrodedAFT CABIN WET AREA FLOOR STRUCTURE CORRODED 15 CM FORWARD OF C70 AND 110CM FROM RH SIDE GROUNDED - YES. REMOVED AND REPLACED FLOOR STRUCTURE FROM FR68 TO FR70 IAW A319 SRM 51-42-11. THIS IS A CATEGORY "A" REPAIR. (NO ALLOWABLE DAMAGE LIMITS GIVEN IN A319 SRSDR AALA2020021329033Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON LATERAL WINDSHIELD FRAME RIGHT HAND SIDE BETWEEN FR 4 AND FR 8 AT -Y1292. REPLACED WINDSHIELD FRAME PER EA 302020.SDR AALA2020021329032Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON LATERAL WINDSHIELD FRAME LEFT HAND SIDE BETWEEN FR 4 AND FR 8 AT Y1292. REPLACED WINDSHIELD FRAME PER EA 302015.SDR SWIA2020021148399Fitting · corroded* CORROSION DETECTED ON (L/H) SIDE OF FWD NOSE JACK FITTING (UNDER FLOOR) ON "FLANGE" OF SUPPORT FITTING AROUND SEVERAL FASTENER BUCKTAILS COMMON TO BELLY SKIN (MARKED). (C-CHECK) RO 2/07/2020 REPLACED NLG JACK FITTING SUPPORT REF DWG AND SRM. NO LEAKS FOUSDR R61A202001250068Crossbeam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND FRAME 14 CROSSBEAM CORRODED @ TWO AREAS OTBD OF TRACK RIGHT. REPAIRED FRAME 14 CROSSBEAM CORROSION
@ TWO AREAS OTBD OF TRACK RIGHT BY CUT OUTS, INSTALLATION OF DOUBLER AND REPAIR ANGLE REF SRM 53-00-10 REPAIR 03. TOP COATESDR R61A202001250067Doubler · corrodedDURING HEAVY CHECK MAINTENANCE FOUND RH DOUBLER CORRODED IN FOUR AREAS BETWEEN FRAMES 13/14. REMOVED RH FLOOR DOUBLER BETWEEN
FRAMES 13-14 AND INSTALLED A NEW ONE.REF EMB SRM 51-40-08. A/C REMAINS IN CHECK.SDR C77A2020011000001Crossbeam · corrodedTHIS EO IS BEING ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF CORROSION DAMAGE DISCOVERED DURING BASIC CHECK AT EAMS ON THE UPPER FLANGE OF THE FR84 CROSSBEAM IN THE CABIN FLOOR STRUCTURE OF THE CENTER FUSELAGE III. REFER ETD2020-170-00SDR SWAA2021060425903Window Frame · crackedDTIP REPAIR SURVEY-SWA INSTALLED REPAIR TABLE 1-1 OF EA 1-751-0974-RH #3 WINDOW FRAME; E-F POST CRACK REPAIRED PER ACO 8274-53. REFERENCE T751851. / NO FURTHER EVALUATION IS NECESSARY PER EA 1-751-0974SDR ASAA2020022092212Door Frame · corrodedDOOR R2 CUT OUT HAS SEVERAL AREAS OF CORROSION, MARKED GROUNDED - YES. REMOVED CORROSION - ORIGINAL THICKNESS .177, REMAINING .085, REMOVED .092 AND FOUND TO BE OUT OF LIMITS IAW A319 SRM 53-14-11. REMOVED AND REPLACED DOOR SILL P/N D5348004320701 IAW ASDR AALA202002139018Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION ON FLIGHT DECK CENTER WINDSHIELD RIGHT HAND CENTER POST FRAME LOWER ATTACHMENT LOWER RADIUS AT FR 2 AND Y0. REPLACED FRAME PER EA 302013.SDR SWIA2020021148356Structure · corroded* L/H SIDE MLG WHEEL WELL STRUCTURE JUST AFT OF FLAP THERE IS CORROSION. FS 559.0 (C-CHECK) RO 2/07/2020 EVALUATED STIFFENER - FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED STIFFENER (P/N 601R32026-95) WITH NEWLY FABRICATED PART. REF CRJ200 SRM AND BOMBASDR R61A202001310130Doubler · corrodedWHILE IN HEAVY CHECK FOUND CORROSION AFT WET AREA ON RH DOUBLER AT FRAME 84. REMOVED RH DOUBLER AT FRAME 84(AFT WET AREA) IN REF. SRM 51-40-08 INSTALLED NEW RH DOUBLER AT FRAME 84(AFT WET AREA) IN REF. SRM 51-40-08.SDR R61A202001310127Crossbeam · corrodedWHILE IN HEAVY CHECK FOUND FRAME 14 CROSSBEAM CORRODED @ TWO AREAS OTBD OF TRACK RIGHT. REMOVED DAMAGED BY BLENDING AT FWD WET AREA RH CROSSBEAM FR14 DIMENSIONS L=5 X W=1 X H=.032,.044IN. NOMINAL THICKNESS .120 ALLOWABLE DAMAGE 10% FOUND TO BE OUT OF LIMITS RESDR R61A202001270094Crossbeam · corroded***AIRCRAFT IS IN HEAVY CHECK*** CORROSION AND SCRIBE MARKS FOUND AT CROSSBEAM, FR 84 BTW RBL 5 AND RBL 36. REPAIRED CROSSBEAM IAW ETD2020-170-001102. ***AIRCRAFT REMAINS IN HEAVY CHECK***SDR R61A202001250065Doubler · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION AFT WET AREA ON RH DOUBLER AT FRAME 84. REMOVED DAMAGED RH DOUBLER AT
FRAME 84(AFT WET AREA). LOCATED, DRILLED AND INSTALLED NEW RH DOUBLER AT FRAME 84(AFT WET AREA). SURFACE PROTECTION APPLIED. REF. SRM
51-40-0SDR F3LA2020012390003Fitting · crackedLOWER AFT FASTENER HOLE ON L/H FRAME 16 UPPER DOUBLE JOGGLE SHOWS CRACK INDICATIONS. REPAIRED L1 DOOR FRAME 16 UPPER DOUBLER JOGGLE HOLE 'D' IAW REPAIR DRAWING R53113041 (ISSUE E). REPAIR INSPECTION THRESHOLD 6800 FC WITH INTERVALS OF 4129 FC PER RDAS.SDR 2A6D2020011300101Deck Plate · gougedTRANSMISSION DECK HAS A GOUGE ON THE RIGHT SIDE LOCATED AT APPROXIMATELY STA 3732, WL -2750, AND BL 385R. THE DAMAGE IS APPROXIMATELY .6" LONG AND .2" WIDE AND .022" AT ITS DEEPEST POINT.SDR REXA2020021280151Angle · corrodedINITIAL INSPECTION: CORROSION ON MID CAP ANGLE AT PASSENGER DOOR SURROUND STRUCTURE (SM)(FUS)(TCI:53-20-220)
SUMMARY OF NRC 00197, CORROSION LEVEL-2: MID CAP ANGLE AT PASSENGER DOOR SURROUND STRUCTURE WAS REPLACED PER CRJ-900 SSDR RAIA2020011508001Door Frame · crackedCOCPIT UNDERFLOOR HATCH 123BL FRAME IS CRACKED BELOW HINGE BRACKET- REMOVED DAMAGE. FABRICATED DOUBLER AND FILLER. LOCATED AND DRILLED REPAIR PARTS. INSTALLED REPAIR PARTS.SDR SWIA2020020648236Post · damagedF.S 409+128 BL 0.0 DEFECTS NOTED AT LH / RH AFT RADIUS OF VERTICAL POSTS. (C-CHECK) RO 2/04/2020 REPLACED LH/RH VERTICAL POSTS AND 2EA CLIPS @ FS409.00 + 128 BL0.0. REF CRJ200 SRM 51-42-06, CRJ200 SRM 51-42-22, BOMBARDIER DWG 601R32208 REV-T, AND BOMBARDIESDR SWIA2020011647798Crossbeam · crackedAFT WET AREA FRAME 85 CROSSBEAM RH AND LH FLOOR BOARD SUPPORT BRACKET ARE CRACKED (C-CHECK) RO 1/15/2020 REMOVED AND REPLACED FLOOR BOARD SUPPORT BRACKET ON LH AND RH SIDE OF FR 85 CROSSBEAM. REF. RESTORED SURFACE PROTECTION ON FLOOR BOARD SUPPORT BRACKETSDR SWAA2021070712536Pressure Deck · damagedCOCKPIT FLOOR IS DAMAGED BS256 BL0-LBL13 WL 208 / REPAIRED DAMAGED FLOOR WEB AT BS 250-270 RBL10-LBL20 IAW EA 1-A53-33179 REV: IRSDR SWAA2021060412561Window Frame · cracked(SKYLINE DTIP) FLIGHT DECK #1 WINDOW FRAME CRACK REPAIRED PER ACO 8465-53. (T559595) / NO FURTHER EVALUATION IS NECESSARY PER EA 1-751-1130.