What was found
WHILE IN HEAVY CHECK FOUND FRAME 14 CROSSBEAM CORRODED @ TWO AREAS OTBD OF TRACK RIGHT. REMOVED DAMAGED BY BLENDING AT FWD WET AREA RH CROSSBEAM FR14 DIMENSIONS L=5 X W=1 X H=.032,.044IN. NOMINAL THICKNESS .120 ALLOWABLE DAMAGE 10% FOUND TO BE OUT OF LIMITS REF EMB SRM 53-10-10AD02. PERFORMED CUT OUT OF 2EA DAMAGED AREAS ON FR14 REF EMB SRM 53-00-10 R03 FABRICATED, DRILLED, TREATED AND PRIMED REPAIR PARTS FOR FR14 REPAIR REF EMB SRM 53-00-10 R03 INSTALLED REPAIR PARTS REF EMB SRM 53-00-10 R03