SDR SWAA2019080635583Rail · corrodedAFT CARGO BAY RAIL CORRODED AT BS. 767+6, RBL 3. / REPAIRED FLOOR BEAM IAW EA.SDR SWAA2019080635582Rail · corrodedAFT CARGO BAY RAIL CORRODED AT BS. 767+6, LBL 8. REPAIRED FLOOR BEAM IAW EA.SDR R61A201907050704Beam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND L1 DOOR LOWER BEAM CORROSION NOTED AT AFT AND FWD GIRT BAR FITTINGS. REMOVED AND REPLACED L1 LOWER BEAM
REF SRM 51-40-08. APPLIED TOP COAT REF SRM 51-23-06. A/C REMAINS IN CHECK.SDR SWAA2019081535961Pressure Deck · crackedHORIZONTAL PRESSURE DECK CRACKED BETWEEN BS. 663 TO BS. 675, LBL 32. REPAIRED PRESSURE DECK IAW ER AND EA.SDR AALA20190815036Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT AFT DOOR CUT OUT CORNER FITTING AT FR 68 AND S23R. REPLACED CORNER FITTING PER SRM 51-72-11.SDR DALA2019070404016Window Post · crackedCRACK INDICATION ON FRAME 4 WINDSHIELD SIDE POST, LOWER ATTACHMENT, VERTICAL FLANGE, INTERNAL LH SIDE IN COCKPIT (1 EA). PERFORMED REPAIR ON FR4 WINDSHIELD SIDE POST, LOWER ATTACHMENT, VERTICAL FLANGE INTERNAL COCKPIT LT SIDE ASPER ER.A NO. 579075-14AD REV.ORISDR DALA2019122307506Door Frame · crackedFWD CARGO DOOR FRAME FORKS FOUND CRACKED AND HAD OVERSIZED HOLES. REPAIRED IAW WITH ER/A 581907-14AD, REV ORIGINAL. ALL OTHER WORK ACCOMPLISHED ON SHOP ORDER PS4865.SDR SWAA2022031150401Stiffener · crackedRT WHEEL WELL; RBL 24 VERTICAL STIFFENER CRACKED. / REMOVED AND REPLACED RT WHEEL WELL STIFFENER AT RBL 24 PER SRM 51-40-02SDR SWAA2022031160488Web · corroded***CORROSION*** ON 1016 WEB AT AFT CABIN BS1016 LBL19 WL208. MARKED / CORROSION ON WEB BS1016 LBL19 WL208 FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS GIVEN IN SRM REPAIRED PER ATS ER 19-04030 REV IR AND EA 1-753-35322 REV IRSDR ABXR2019072600038Plate · corrodedCORNER OF PICKLE CORRODED.SDR KCSA201907011155Reveal · crackedBS 2231 RT DOOR REVEAL CRACKED BETWEEN STR 21 R & 22 R.SDR DALA2019070103953Door Frame · crackedBENT ON AFT COMPARMENT CARGO DOOR JAMB STA 992 BTW L25R TO L24R (FUS). NRC 00089: A CRACK OF 0.500" IN LENGTH, WAS FOUND AFTER FORMING. CRACK ON AFT COMPARMENT CARGO DOOR JAMB STA 992 BTW L25R TO L24R WAS REPAIRED PER SRM 53-20-15-2R-4 PAR. 4. (LP #1148784)SDR AALA2019080879043Pressure Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED PRESSURE PLATE AT FR 36 AND -Y1292. REPAIRED PRESSURE PLATE PER EA 296108SDR VOXD201906290206Pressure Deck · corrodedCORROSION DAMAGE AND OVERSIZE FASTENER HOLES TO THE PRESSURE FLOOR SILL AND ANGLES. REFERENCE ( DWG: SH^()-36110, REF BETWEEN FS 708.00 AND FS 813.70. ACCOMPLISHED ULTRA SOUND FOR THICKNESS AND HFEC FOR FURTHER CORROSION OR CRACKS. NO DEFECTS NOTED AT THIS TIMSDR AC2R2019062813901Structure · crackedCRACKS FOUND AT STA3120 OVERHEAD AFT AND FORWARD SIDE AT BOTH CB PANEL ANGLE LOWER ENDS.SDR AC2R2019F00231Structure · crackedCRACKS FOUND AT STA3120 OVERHEAD AFT AND FORWARD SIDE AT BOTH CB PANEL ANGLE LOWER ENDS.SDR SWAA2022031156463Intercostal · crackedAFT E&E COMPARTMENT INTERCOSTAL CRACKED LH STA 312-328 / REMOVED AND REPLACED INTERCOSTAL PER SRM 51-40-02 AND SRM 51-10-02SDR AALA201908209054Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK UPPER RIGHT HAND LATERAL WINDSHIELD FRAME CRACKED AT FR 4 AND Z210. REPLACED FRAME PER EA 295867.SDR CALA2019070201106Stop Fitting · crackedRT FR 66 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION. REF N/R 9620197. REAMED RT FR66 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-12-300-010, SRM 51-44-11-001, NTM 51SDR CALA2019070201105Stop Fitting · crackedLT FR 68 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION. REF N/R 9620198. REAMED LT FR68 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-300-010, SRM 51-44-11-001, NTM 51-10SDR CALA2019070201107Door Frame · crackedLT FR 66 #1 DOOR STOP FITTING I/B LOWER FASTENER HOLE HAS CRACK INDICATION, REF N/R 9620196. REAMED LT FR66 #1 DOOR STOP FTG I/B LOWER HOLE TO .280". ROTO PROBE PERFORMED, NO CRACK INDICATION. PERFORMED REPAIR IAW SRM 53-41-12-300-010, SRM 51-44-11-001, NTM 51SDR 2019FA0000205Pressure Deck · corrodedCORROSION TO LHS AFT PRESSURE SILL DECK. ORIGINAL THICKNESS .080. BLENDED AREA 1.80L X W.080 X .040 MINIMUM REMAINING THICKNESS. ACCOMPLISHED HFEC AND ULTRA SOUND INSPECTION OF DEFECTED AREA. REPAIRED AREA PER BOMBARDIER REO 690-53-41-189 REV (A). REPETITIVE SDR SWAA2022031127966Angle · crackedAFT CARGO 727 BULKHEAD LOWER CENTER VERTICAL SUPPORT ANGLE CRACKED. / REMOVED DAMAGED VERTICAL SUPPORT ANGLE AT AFT CARGO STA 727 PER SRM 51-40-02. INSTALLED NEW VERTICAL SUPPORT ANGLE PER SRM 51-40-02.SDR SWAA2022031165241Gusset · crackedFWD CARGO BAY 500D GUSSET IS CRACKED STR 19L/H / REMOVED GUSSET B.S. 500D STR 19 L/H PER SRM 51-40-02-0G-0 DRILLED AND LOCATED GUSSET PER SRM 51-40-05; OK TO INSTALL 556823R INSP 18 2JUL19 INSTALLED GUESSET PER SRM 51-40-02-0G-0 AND DWG 143A7902SDR SWAA2022031165242Gusset · crackedFWD CARGO BAY 500D GUSSET IS CRACKED STR 19R/H / REMOVED GUESSET B.S. 500D STR19 R/H PER SRM 51-40-02-0G-0 DRILLED AND LOCATED GUSSET PER SRM 51-40-05. OK TO INSTALL 56823R 02JUL19 INSP 18 2JUL19 INSTALLED GUSSET PER SRM 51-40-02-0G-0 AND DWG 143A7902SDR SWAA2022031165244None · corroded***CORROSION*** ON FWD CARGO BAY 500D LWR BULKHEAD SUPPORT HAS CORROSION LBL 19 - RBL 19 WL 156 / REMOVED AND REPLACED LWR BULKHEAD SUPPORT BALL ASSY B.S. 500D LBL 19. RBL 19. WL 156 PER SRM 51-10-02-0G-0 SRM 51-40-02-0G-0 AND DWG 143A7902SDR SWAA2022031109769Channel · bentBENT ACB FLOOR SUPPORT STA 727E-747 RBL 3 WL 157 / REPAIRED AFT CARGO BAY; FLOOR SUPPORT CHANNEL AT BS 727E-747 RBL 3 WL 157 I.A.W SRM 53-00-53-2R-4 88302U 12JUN19SDR AALA201908209039Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK LEFT HAND CENTER WINDSHIELD FRAME CRACKED AT FR 2 AND Y0. REPLACED FRAME PER EA 295864.SDR AALA2019080659068Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED RIGHT HAND WINDSHIELD FRAME AT FR 2 AND Y0. REPLACED WINDSHIELD FRAME PER EA 295811.SDR AALA2019080659063Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED RIGHT HAND WINDSHIELD FRAME AT FR 2 AND Y0. REPLACED WINDSHIELD FRAME PER EA 295811.SDR DALA2019062803921Window Frame · crackedCRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER ATTACHEMENT AREA INTERNAL SIDE INNER VERTICAL FACE LH FROM UPPER BOLT TO RADIUS (L=0.150) IN COCKPIT (1 EA), PERFORMED REPAIRS INSTRUCTIONS ON FR2 WINDSHIELD CENTER POST LOWER ATTACHMENT INTERNAL SIDE INSDR SWAA2022031165179None · crackedCRACKED FED MOPSILL AT BS 303 LBL 60 WL 208 / REMOVED FLOOR PANELS 221BF; 221DF; AND 221GF FOR ACCESS PER AMM 53-21-00-000-801. REMOVED CRACKED MOPSILL PER SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW FED MOPSILL PER SRM 51-40-05-0G-0. INSTALLED NEW FED MOPSILL SDR SWAA2022031109751Support · corroded***CORROSION*** ON FORWARD CARGO BAY AFT BULKHEAD RIGHT PANEL LOWER SUPPORT AT B.S. 500D; R.B.L. 23; W.L. 155. / REMOVED AND REPLACED R/H LOWER SUPPORT PANEL FCB AT BS500D IAW SRM 51-40-02-0G-0 AND DWG 143A9481 - 143A7902 59205U 15JUL19SDR AALA201908209048Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: FLIGHT DECK RIGHT HAND CENTER WINDSHIELD FRAME CRACKED AT FR 2 AND Y0. REPLACED FRAME PER EA 295864.SDR AALA2019080659064Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED RIGHT HAND LATERAL WINDOW FRAME AT FR 4 AND Y625. REPLACED WINDOW FRAME PER EA 295817.SDR AALA2019080659060Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED LEFT HAND LATERAL WINDOW FRAME AT FR 4 AND Y625. REPLACED WINDOW FRAME PER EA 295816.SDR AALA2019080659059Window Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED LEFT HAND WINDSHIELD FRAME AT FR 2 AND Y0. REPLACED WINDSHIELD FRAME PER EA 295811.SDR AALA201907019058Crease Beam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT CREASE BEAM INBOARD CHORD BETWEEN BS 953 AND BS 989. REPLACED CREASE BEAM PER 51-00-05-1.SDR CALA2019062901086Not Reported · corrodedAFT CARGO FLOOR FR59 STR43 RT CORRODED. REMOVED AND REPLACED STR43RT FR57-60 IAW SRM 51-42-11 AND S RM 51-72-11-911-001.SDR DALA2019062703894Fork · crackedCRACK INDICATION ON DOOR FRAME FORK FR25 HOLE H1 (CRACK DIRECTION IS 1 0 AND 4 OCLOCK) IN FWD CARGO COMPARTMENT (2 EA), PERFORMED PERMANENT REPAIR ON DOOR FRAME FOR FR25 HOLE H1 AS PER ER/A 577975-14AD REV 4 AND PRI 577975-14 REV 0,1,2 AND 3SDR UIEA2019062704605Mount · wornFWD CARGO L/H SIDE AIR COOLING FAN AFT MOUNT IS WORN.(<P>REMOVED AND REPLACED FWD CARGO L/H SIDE AIR COOLING FAN AFT MOUNT IAW B767 AMM 21-58-06. PERFORMED A SATISFACTORY POST FAN INSTALLATION CHECK. NO LEAKS NOTED IAW B767 AMM 21-58-06.</P>)SDR DALA2019062703878Door Frame · crackedCRACK ON WEB OF FUSELAGE DOOR FRAME STA. 208, LONGERON 11 LH. (CPAX). NRC 00530: WEB OF FUSELAGE DOOR FRAME WAS REPAIRED PER B717-200 SRM 53-10-15-2R PAR. 4. (LP #1142067)SDR DALA2019062703876Retainer · crackedCRACK AT AFT UPPER EDGE RETAINER ON LH SLIDE WINDOW WAS FOUND (CPIL). NRC 00654: AFT UPPER EDGE RETAINER ON LH SLIDE WINDOW WAS REPAIRED PER B717-200 SRM 56-10-02-2R. (LP #1142006)SDR C77A2019062600005Crossbeam · corrodedEO E175-53MR-143 REV IR WAS ISSUED TO PROVIDE INSTRUCTIONS TO ACCOMPLISH THE PERMANENT REPAIR OF CORROSION DAMAGE TO THE FR17 CROSSBEAM UPPER FLANGE (REF ETD2013-170-020767 FOR DAMAGE DIMENSIONS AND LOCATIONS). ORIGINALLY, CORROSION DAMAGE TO THE TRACK WAS RESDR C77A2019062600004Crossbeam · corrodedCORROSION DAMAGE DISCOVERED DURING THE B6 BASIC CHECK AT EAMS ON THE UPPER FLANGE OF THE FR17 CROSSBEAM IN THE CABIN FLOOR STRUCTURE OF THE FORWARD FUSELAGE. REFERENCE FIGURE 1 FOR DETAILS. THE DAMAGE MEASURES APPROXIMATELY 1.5 INCHES X 0.9 INCHES TO A DEPTH SDR A6WA2019062646679Beam · gougedDAMAGE FOUND ON FWD LOWER PORTION OF CARGO DOOR BEAM THAT REQUIRES FURTHER INSPECTION. CABLE GOUGED INTO BEAM IN TWO PLACES.SDR SWAA2022031140326Baffle · crackedACB BILGE BAFFLE CRACKED; STA 927-947; RBL 22 / REMOVED ACB BILGE BAFFLE; STA927-947; RBL22 IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED NEW BAFFLE I.A.W SRM 51-40-05-0G-0 AND DWG 147A7500 ID:0004 REV:C. INSTALLED NEW BAFFLE I.A.W SRM 51-40-02-0G-0 AND DWG 147A7SDR SWAA2022031140334Angle · corroded***CORROSION*** ON FORWARD SERVICE DOOR MOP SILL AT B.S. 328-344; R.B.L. 60; W.L. 208.1. / REMOVED CORROSION ON F.S.D MOPSILL BS 328-362 RBL 60 WL 208.1 34' X 3' X .003'; REMAINING THICKNESS .077' ORIGINALL THICKNESS .080' FOUND TO BE WITHIN LIMITS PER SRM 53-SDR SWAA2022031140332Angle · corroded***CORROSION*** ON FORWARD ENTRY DOOR MOP SILL AT B.S. 308-344; L.B.L. 60; W.L. 209. / REMOVED AND INSTALLED A NEW FED ATTACH MOPSILL ANGLE IAW SRM 51-40-02-0G-0; DWG 141A8110. BLENDED CORROSION ON MOPSILL AT B.S 308-344; LBL 60 IN A 1.7' X 0.8' X .006' AREA FSDR SWAA2022031142009Shear Tie · crackedSHEAR TIE CRACKED AT BS 500C JUST ABOVE STRINGER 28 RH / REMOVED CRACKED SHEAR TIE AT STA. 500C JUST ABOVE STR 28 R/H I.A.W. B737 SRM 51-40-02-0G-0 LEAD293 24JUN19. INSTALLED NEW REPLACEMENT SHEAR TIE ON BS 500C; BETWEEN STR 27R AND 28R; IAW SRM-51-40-07-0G-0;