What was found
***CORROSION*** ON FORWARD ENTRY DOOR MOP SILL AT B.S. 308-344; L.B.L. 60; W.L. 209. / REMOVED AND INSTALLED A NEW FED ATTACH MOPSILL ANGLE IAW SRM 51-40-02-0G-0; DWG 141A8110. BLENDED CORROSION ON MOPSILL AT B.S 308-344; LBL 60 IN A 1.7' X 0.8' X .006' AREA FROM .090' ORIGINAL PER SRM 51-10-02-0G-0. FOUND TO BE IN LIMITS PER SRM 53-10-15-1A-1. APPLIED CHEMICAL CONVERSION AND PRIMER TO BLEND AREA IAW SRM 53-10-15-1A-1 STEP 2 B; C