JASC 5310
Service difficulty reports · 38,548
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RAIA201801230004Door Frame · corrodedCARGO DOOR TOP CENTER FRAME IS CHAFED AT THE FWD UPPER CORNER. R & R THE CARGO DOOR TOP CENTER FRAME.SDR FDEA201801230179Shear Plate · corrodedMAIN UPPER CABIN, SEC 46 AT BS 1681 HAS AFT SHEAR DECK WITH SPOTS OF SURFACE CORROSION AND BARE METAL ON ENTIRE LENGTH OF UPPER STRUCTURE FROM LEFT TO RIGHT SIDES OF FUSELAGE WHERE NUTPLATES ARE INSTALLED FOR FLOORBOARDS. REMOVED CORROSION AND FOUND TO BE OUSDR DALA2018012400455Window Frame · crackedCRACK INDICATION ON THE WINDOW FRAME STIFFENER, REPLACED THE WINDOW FRAME IAW PRI 563907-14, REV 0, PRI:563907-14, REV 1, PRI 563907, REV 2, AND ER/A 563907-14AD.SDR SWAA2022020713738Intercostal · elongatedFCB; INTERCOSTAL; BS 490+4.5; RBL 21; HAS ELONGATED FASTENER HOLE. / REMOVED INTERCOSTAL WITH ELONGATED HOLE FCB BS 490 & 4.5. FABRICATED INTERCOSTAL AND INSTALLED PER SRM 51-40-02-0G-0 AND PER DWG 143A0080.SDR SWAA2022020767433Strap · corrodedFORWARD CARGO L/H #3 FLOOR STRAP HAS LIGHT SURFACE CORROSION. / REMOVED AND REPLACED DAMAGED STRAP PER SRM 51-10-02 PT.9.SDR SWAA2022020797008Angle · crackedAFT CARGO RH TRANSITION ANGLE CRACKED AT STA 747+12. / REMOVED AND REPLACED RH TRANSITION ANGLE FROM STA. 727 TO STA. 767 PER SRM 51-40-02.SDR AALA201802129057Beam · corrodedCORROSION ON BEAM BETWEEN FRAMES 71 AND 72. REPLACED BEAM IAW SRM 51-72-11-911-001, AND DWG F53478101.SDR AALA201802129056Beam · corrodedCORROSION FOUND ON THE BEAM ASSEMBLY LOCATED BETWEEN -0YA TO -YB, AND BETWEEN FRAMES 71 AND 72. REPLACED THE BEAM IAW SRM 51-42-11, SRM 51-72-11, AND DWG F53478101.SDR DALA2018012200328Door Frame · corrodedCORROSION FOUND ON THE R1 DOOR FRAME, AFT SIDE OF THE FRAME AT THE CUSP. REPAIRED IAW SRM 53-05, FIG 55.SDR AALA201802169021Crossbeam · crackedCRACK LOCATED ON THE CROSSBEAM, FRAME 74, Y1453. REPAIRED THE CROSSBEAM IAW SRM 53-00-14-300-002, FIGURE 20102.SDR AALA201802129055Beam · corrodedCORROSION FOUND ON THE BEAM LOCATED BETWEEN FRAMES 73 AND 74, -YA AND YB1. REPLACED BEAM IAW SRM 51-42-11, SRM 51-72-11, AND DWG F53478018.SDR DALA2018012200445Strap · corrodedHORIZONTAL STAB JACKSCREW COMPARTMENT RIGHT SIDE, AFT OF BULKHEAD FRAME BS 1787, STRINGER 3R TO 5R. THE NUTPLATE STRAP CORRODED ON FORWARD END OF APU INLET DOOR HOUSING. REMOVED CORROSION AND FOUND BEYOND LIMITS IAW SRM. REMOVED AND REPLACED THE STRAP IAW SDR DALA2018012200335Crease Beam · corrodedCORROSION FOUND ON THE CREASE BEAM, BETWEEN BS 847 & 867 + 4 INCHES. REPAIRED THE CREASE BEAM IAW ERA 563921-14, REV ORIGINAL, AND PRI 563921-14, REVISIONS 0 - 3.SDR AALA201802129058Fitting · corrodedCORROSION FOUND ON HARD POINT FITTING BETWEEN FR15 AND FR17, AND Y-953, AND Y-1456. REPLACED HARD POINT FITTING PER SRM A330 51-72-11 AND DRAWING F25310032.SDR ASOA201801205039Intercostal · chafedINTERCOSTAL AT BS 725 ON BETWEEN LBL 27 AND LBL 36 IS FOULING ON HYDRAULIC LINE ON BOTTOM INBOARD SIDE. REPAIRED INTERCOSTAL IAW BOMBARDIER REO 670-53-41-353 REV-- DATED 2018-01-16 AND EXPRESS JET EC/TC REO 670-53-41-353.SDR A6WA2018012545594Support · corrodedPAX DOOR CUT OUT STRUCTURE CORRODED, FS 310.00 TO 349.00 STR 18L. REPLACED ANGLE SUPPORT IAW SRM 51-42-06, 51-42-21, 53-21-23.SDR AALA20180120009Window Frame · crackedA CRACK WAS FOUND IN THE UPPER CORNER OF FIRST OFFICERS R1 WINDOW POST BETWEEN BS 178 TO 259.5. INSTALLED A DOUBLER & TRIPPLER IAW EA 276046A.SDR SIMA20180120003Structure · corrodedCORROSION IN LATERAL L SHAPE AT FRAME 65, DOOR STOP. REMOVED CORROSION, FOUND OUT OF LIMITS, REMOVED DAMAGED AREA, LOCATED , DRILLED AND INSTALLED A SPLICE. ALODINED, PRIMED, AND PAINTED IAW SRM 53-31-04, 51-20-03, 51-40-02, CPM 51-21-04, 51-21-05, AND 51-21SDR SWIA201844211Structure · crackedPOSSIBLE CRACK FOUND UNDER ACCESS DOOR 211AL AFT LATCH. REMOVED AND REPLACED THE DOOR LANDING SKIN IAW SRM.SDR SIMA20180119001Door Frame · gougedCARGO DOOR HAS A GOUGE AROUND NUTPLATE HOLE ON AFT FRAME SIDE. REMOVED DAMAGE, PERFORMED HFEC INSPECTION, NO DEFECTS NOTED, FABRICATED AND INSTALLED A FILLER AND DOUBLER. INSTALLED THE DOUBLER AND FILLER IAW SRM 52-30-04, NDTM 51-00-00-916-801-00, CPM 51-2SDR DALA2018011900343Crease Beam · damagedSHIP 670 CREASE BEAM OUTBD CHORD STA 590 STR. 17LT HAS AN OVERSIZED (.313 " FASTENER HOLE). CORRECTIVE ACTION: REFERENCE ERA 556473-14. (0387915)SDR SWAA2022020713733Baffle · crackedFCB; BAFFLE AT BS 500 TO BS 500A; IS BENT CRACKED / REMOVED AND REPLACED FCB BAFFLE AT BS 500 TO 500A (L/H) I.A.W. SRM 51-40-02-0G-0; FAB NEW 143A7510-7 BAFFLE FROM 7075-T6 .020' CLAD LOT # 1261855 PER DWG. #143A7510 88919U 23JAN18SDR IPXA2018012525890Door Frame · puncturedINSPECTION TYPE: 2C, MAIN CARGO DOOR FWD FRAME HAS A PUNCTURE. REMOVED, FABRICATED, AND REPLACED FRAME IAW DWG ACA7301-3, AND SRM 51-35-01.SDR CALA2018011900221Support Beam · crackedFWD CARGO DOOR FRAME LOWER BEAM FOUND CRACKED AT RBL48, BS 500 & 566. A NEW SUPPORT BEAM WAS REINSTALLED IAW SRM 51-10-02 AND AMM 20-11-00.SDR SWAA2022020712380Intercostal · crackedUPPER CORD CRACKED TWO PLACES ON CABIN FLOOR PANEL INTERCOSTAL; BL-0; BETWEEN STA'S 380 & 400 / REMOVED AND REPLACED UPPER CARD AT STA. 380-400; BL0 IAW SRM 51-40-02-OG-0 AND DWG 143A5400; ID .54.SDR SWAA2022020712368Intercostal · corroded***CORROSION*** STA 500- STA 500A LBL 21 INTERCOSTAL AT FASTENER HOLES / REMOVED CORROSION ON INTERCOSTAL BS 500-500A LBL 21 IN AREA OF 1' X .75' X .020. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. LEAKED; DRILLED AND INSTALLED AND INSTALLED NEW INTERCOSTSDR DALA2018080583210Door Frame · crackedFWD CARGO DOOR FRAME FORKS HAD OVERSIZED AND CRACKED HOLES AT FRAMES 54 - 54A. REPAIRED IAW ER/A 570292-14AD SECTION 1.SDR JXK2018F00000Door Frame · crackedDURING INSPECTION, A CRACK WAS FOUND ON THE LOWER LEFT PORTION OF THE CABIN DOOR FRAME AT BS 243.38. THE CRACK ORIGINATES FROM A BEND RELIEF CUTOUT IN A HEAVILY FORMED SECTION OF THE FRAME. THIS IS THE THIRD AIRCRAFT WE FOUND THIS CRACK PRESENT, SAME MAKE ASDR SWAA2018021519716Door Frame · crackedR1 DOOR LOWER FRAME CRACKED AT BS 294.5. REPAIRED THE DOOR FRAME IAW ER AND EA.SDR AALA201802089047Crossbeam · corrodedCORROSION FOUND ON THE CROSSBEAM LOCATED AT FRAME 75, -Y450, IN THE AFT GALLEY AREA. PERFORMED A PERMANENT REPAIR ON THE CROSSBEAM IAW SRM 51-42-11, AND SRM 53-00-14-300-002.SDR SWAA2022020736000Gusset · crackedFWD CARGO GUSSET CRACKED STR19R STA 500I / REMOVED AND REPLACED FWD CARGO GUSSET AT STA. 500I STR 19R IAW SRM 51-40-02-0G-0 AND DWG 143A7902.SDR SWAA2022020736003Support · corroded***CORROSION*** FWD CARGO FLOOR TO SIDEWALL SUPPORT BS 500B+13 TO 500D+10 LBL23 / CORROSION ON FWD CARGO FLOOR TO SIDEWALL SUPPORT STA 500B+13 - 50D+10 LBL23 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT STA 50SDR SWAA2022020736008Support · corroded***CORROSION*** AFT CARGO FLOOR TO SIDEWALL SUPPORT BS 727D - 6 TO 847 LBL 20 / DAMAGE AT AFT CARGO FLOOR TO SIDEWALL SUPPORT B727D+6-847 FOUND TO BE L 2' W 1.5' D .010' ORIGINAL THICKNESS .040' FOUND TO BE OUT OF LIMITS. IAW SRM 53-00-53-1A-2. REMOVED DAMAGEDSDR SWAA2022020736007Support · corroded***CORROSION*** AFT CARGO FLOOR TO SIDEWALL SUPPORT BS 727B+6 TO 767 / DAMAGE AT AFT CARGO FLOOR TO SIDEWALL SUPPORT BS 727B+6 - 767 FOUND TO BE L1.5 W1' D.010 ORIGINAL THICKNESS .040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 REMOVED DAMAGED SECTION 727SDR SWAA2022020736004Support · corroded***CORROSION*** FWD CARGO FLOOR TO SIDEWALL SUPPORT BS 500A TO 500I RBL23 / REMOVED CORROSION FROM AFFECTED AREA. ORIGINAL MATERIAL THCKNESS WAS .040'. MATERIAL LOSS WAS GREATER THAN 10% AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIG. 103 REPAIREDSDR R61A201802010116Beam · corrodedCORRODED BEAM Y=10.748. REMOVED, FABRICATED, LOCATED, DRILLED, AND INSTALLED A NEW BEAM FR 88 IAW SRM 53-23-10R01, AND 51-40-02.SDR UIEA2018012900126Door Frame · crackedFOUND A CRACK ON THE R2 DOOR FRAME BS 800, STRINGERS 16R - 17R. FABRICATED A STRAP IAW EI T2017P53M-3016, SEQUENCE A, REV 0. REPAIR THE FRAME IAW EI T2017A53M-3013 SEQUENCE A REV 1, AND SRM 53-20-07, REPAIR 12, REV 101.SDR UIEA2018012900128Support Frame · crackedCRACK INDICATION ON THE SUPPORT FRAME DURING INSPECTION, BS 2598. REPAIRED IAW EI T2017A53M-3144, REV 2.SDR AALA201801199025Fitting · crackedCRACK DETECTED ON THE R1 DOOR CUTOUT INTERCOSTAL FITTING AT LOWER INBOARD BOLT HOLE AT #7 DOOR STOP FITTING AT FR 16R. REPLACED INTERCOSTAL FITTING PER SRM 51-42-11SDR AALA201801199024Fitting · crackedCRACKS DETECTED ON THE L1 DOOR CUTOUT INTERCOSTAL FITTING AT LOWER INBOARD BOLT HOLE AT #7 DOOR STOP FITTING AT FRAM E 16L. REPLACED INTERCOSTAL FITTING PER SRM 51-42-11.SDR DALA2018011700269Box Beam · crackedLEFT BOX BEAM CRACKED IN PRESSURE PLATE LAYER, REPAIRED IAW AMDS 5310-01450-02.SDR DALA2018011700268Box Beam · crackedLEFT BOX BEAM FLANGE FIRST HOLE CRACKED IN FLANGE LAYER. REPAIRED IAWAMDS 5310-01450-02, .SB A320-53-1251 REV 1SDR DALA2018011700267Box Beam · crackedRIGHT BOX BEAM PRESSURE PLATE CRACKED. REPAIRED IAW AMDS 5310-01450-02. IAW SB A320-53-1251, REV 1.SDR DALA2018011700266Box Beam · crackedRIGHT BOX BEAM FLANGE HOLE NUMBER 1 CRACKED IN FLANGE LAYER, REPAIRED IAW AMDS 5310-01450-02. IAW SB A320-53-1251 REV 1SDR QMLA20180116077Doubler · crackedAPPROXIMATELY 1.5 INCH CRACK FOUND ON THE DOUBLER UNDER THE RIGHT FORWARD TRANSMISSION MOUNT.SDR R61A201801150068Support Angle · crackedMAINTENANCE FOUND A CRACK ON THE LT FRAME 52 WEB SUPPORT ANGLE. REMOVED, FABRICATED AND INSTALLED A NEW SUPPORT ANGLE IAW SRM 51-43-03 AND 51-42-01.SDR SWAA2018022119977Deck Plate · crackedHORIZONTAL PRESSURE DECK CRACKED AT BS 664, LBL 33. REPAIRED THE DECK IAW ER & EA.SDR IPXA2018012525885Beam · crackedINSPECTION TYPE: 2C, LOWER FWD CARGO AT BS 6-70, ABOVE LONGERON 43R, HORIZONAL BEAM IS CRACKED ON THE END. REMOVED, FABRICATED, AND REPLACED THE BEAM IAW DWG ADA7667, SRM 51-33-01, AND 51-35-01.SDR DALA2018011700255Door Frame · crackedCRACK IN FWD ACCESSORY COMPARTMENT DOOR JAMB. FWD ACCESSORY COMPARTMENT DOOR JAMB WAS REPAIR AS A PERMANENT REPAIR PER ER/A 564870-14 REV ORIGINAL AND ETI-88-18-001 REV 2.SDR DALA2018011400265Door Frame · crackedCRACKED EMERGENCY EXIT DOOR FRAME. , REPLACED THE DOOR FRAME IAW SRM 51-72-11, AND DRAWING D52279010.
Back to JASC 5310