What was found
***CORROSION*** AFT CARGO FLOOR TO SIDEWALL SUPPORT BS 727D - 6 TO 847 LBL 20 / DAMAGE AT AFT CARGO FLOOR TO SIDEWALL SUPPORT B727D+6-847 FOUND TO BE L 2' W 1.5' D .010' ORIGINAL THICKNESS .040' FOUND TO BE OUT OF LIMITS. IAW SRM 53-00-53-1A-2. REMOVED DAMAGED SECTION FROM 727D+6-847 IAW SRM 51-40-02-0G-0. FABRICATED NEW SUPPORT FROM BAC 1496-377 7075 T62 LOT #5062573-41 IAW SRM 53-00-53-2R-5 TREATED & PRIMED IAW SRM 51-20-01-06 & SOPM 20-41-02 INSTALLED NUT PLATES IAW BOEING DWG #146A7502 REV A INSTALLED NEW SUPPORT IAW BOEING DWG 146A7502 REV A & SRM 51-40-02-0G-0 WITH SPLICES LOCATED AT 727C+11 & 727I+17