JASC 5310
Service difficulty reports · 38,548
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022013109122Support Angle · corrodedAFT CARGO AFT BLKD SUPPORT ANGLE CORRODED BS 947 RBL 22' .MARKED / BLENDED CORROSION FROM BS 947 RBL 22' AFT CARGO AFT BULK HEAD SUPPORT ANGLE IAW SRM 53-00-53-1A-2 ORIGINAL THICKNESS 0.080' LOSS 0.012' REMAINING 0.068' OUT OF LIMITS IAW SRM 53-00-53-1A-2 AAR SDR IPXA2017092722097Crossbeam · crackedMAIN CABIN CROSSBEAM AT FRAME 79, -Y1580 FOUND CRACKED. REPAIRED THE CROSSBEAM IAW EO A300-5310-65636-A.SDR IPXA2017092722096Crossbeam · crackedMAIN CABIN CROSSBEAM AT FRAME 79. Y158D FOUND CRACKED. REPAIRED THE CROSSBEAM IAW EO A300-5310-65636-A.SDR SWIA2017101243857Beam · corrodedRIGHT TRANSVERSE BEAM AT BS 349 IS CORRODED. REPAIRED DAMAGE AT IAW REO.SDR DALA2017091006820Rub Strip · corrodedCORROSION AND DISBONDED LT RUB STRIP ON SETTLEMENT AREA AF FILLET FUSELAGE PANELS. THE RUB STRIP WAS REPLACED IAW SRM 53-20-70-01 AND SRM 51-20-05.SDR DALA2017091006771Door Frame · wornWORN LEFT MLG WW DOOR FRAME AFT CHANNEL BS 937 AND LBL 60. MLG WW DOOR FRAME WAS REPLACED IAW SRM 51-30-2, 51-30-5, SRM 51-10-04 , AND 51-10-3 PAR 14, 21.SDR FDEA201709082870Door Frame · crackedA/C COMPT PACK BAY NR 1, APPROX STA 553 LONG 36 REF PACK BAY DOOR (113DL). FWD FRAME OF DOOR CUTOUT. THE FRAME IS CRACKED. IT HAS APPROX A 2" CRACK NEAR TOP OF THE FRAME. REPAIRED FRAME PER EA 8-5310-T0335533.SDR AALA201709129038Window Frame · crackedWHILE ACCOMPLISHING WORK CARD 26T21053011, RECEIVED A CRACK INDICATION AT A BOLT HOLE ON THE UPPER FLANGE OF THE LEFT SLIDING WINDOW LATERAL FRAME UPPER ATTACHMENT. REPLACED LATERAL WINDSHIELD FRAME IAW EA 272600, DRAWING R53112944000, AND R53112942000.SDR DALA2017090906799Door Frame · crackedCRACKED DOOR FRAME LBL 46, LBL 17, AND RBL 17 AT NLG WHELL WELL. THE DOOR FRAME WAS REPAIRED IAW SRM 53-10-14-2R-2, REPAIR 2, FIG 201.SDR CALA2017090803077Post · crackedLEFT AFT EMERGENCY EXIT DOOR VERTICAL SUPPORT CRACKED. REMOVED AND REPLACED THE VERTICAL SUPPORT IAW SRM 51-72-11-911-001, AND ER 5100R01017 REV D.SDR AALA201710019007Support · corrodedCORROSION ON LEFT AFT GALLEY LOWER SUPPORT AT STRINGER 23L AND FRAME 68. REPLACED THE SUPPORT SRM 51-72-11, DRAWING D53480505 AND D 53-41-14.SDR SWAA2017092516562Crease Beam · corrodedLT CREASE BEAM WEB CORRODED BETWEEN BS 887 TO BS 905. R&R WEB IAW DWG AND SRM.SDR DALA2017090806789Door Frame · crackedCRACK ON THE RT NLG DOOR FRAME. NLG DOOR FRAME WAS REPAIRED IAW SRM 53-10-14-2R, REP 2.SDR DALA2017090806788Door Frame · crackedCRACK ON Y=42 LT SIDE OF NLG DOOR FRAME. THE NLG DOOR FRAME WAS REPAIRED IAW SRM 53-10-14-2R, REP 2.SDR YENA201709070751Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT +Y512, FRAME 64 TO 67+10. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472815.SDR AALA201710099032Window Frame · crackedA CRACK INDICATION ON COCKPIT WINDSHIELD CUTOUT CENTER POST LEFT FITTING. REPAIRED IAW EA 273392.SDR DALA2017091706962Door Frame · bentLEFT APU DOOR CUT-OUT FRAME IS BENT AT BS 1943. REMOVED AND REPLACED THE DOOR FRAME IAW DWG 148N8201, AND SRM 51-40-02.SDR SIMA20170906008Crossbeam · crackedFRAME BS 280 LT SIDE CROSSBEAM CRACKED ON FWD SIDE BELOW CENTER COCKPIT FLOORBOARD. A NEW CROSSBEAM WAS INSTALLED IAW SRM 51--42-06, SRM 51-42-10, AND SRM 51-42-13.SDR SIMA20170906002Beam · damagedPREVIOUS REPAIR FWD OF FR 61 ON LAVATORY CENTER BEAM ELONGATED HOLE DAMAGED. PERFORMED A REPAIR IAW ERS-EM-53MR-2868.SDR V0XD20170906006Floorbeam · crackedRIGHT BS 280 FLOORBEAM IS CRACKED. REMOVED AND REPLACED THE FLOORBEAM IAW 53-11-41, 51-25-06, 51-25-16, 51-21-11, 51-42-13, 51-42-06, 51-42-20, NDTM PART 1 51-20-006, AND AMM 20-70-00.SDR SWAA2017092816735Crease Beam · corrodedLT CREASE BEAM WEB CORRODED AT BS 870. R&R WEB IAW SRM AND DWG.SDR DALA2017090506609Beam · crackedCRACK ON RT BEAM CUT OUT STA Y=47 NLG WHEEL WELL (NLG). DAMAGE AREA WAS REPAIRED PER ER/A 560906-14 REV ORIGINAL. (ET)(HFEC) WAS ACCOMPLISHED PER NDTSPM 06-10-01.001 NO CRACKS WERE FOUND AFTER REMOVED DAMAGE ON RT BEAM CUT OUT STA Y=47 NLG WHEEL WELL.SDR DALA2017090506608Beam · crackedCRACK ON LT BEAM CUT OUT STA Y=47 NLG WHEEL WELL (NLG). DAMAGE AREA WAS REPAIRED PER ER/A 560906-14 REV ORIGINAL. (ET)(HFEC) WAS ACCOMPLISHED PER NDTSPM 06-10-01.001 NO CRACKS WERE FOUND AFTER REMOVED DAMAGE ON LT BEAM CUT OUT STA Y=47 NLG WHEEL WELL.SDR DALA2017090406572Former · crackedCRACKED RT FORMER, BS 737 AT KEEL BEAM AREA. THE FORMER WAS REPAIRED IAW SRM 51-70-11-2R-1.SDR DALA2017090406571Former · crackedCRACKED FORMER ON BS 679 AT KEEL BEAM AREA. THE FORMER WAS REPAIRED IAW SRM 51-70-11-2R-1.SDR DALA2017090406570Former · crackedCRACKED FORMER ON BS 694 AT KEEL BEAM AREA. THE FORMER WAS REPAIRED IAW SRM 51-70-11-2R-1.SDR R61A201709170706Doubler · corrodedCORROSION ON THE CROSS BEAM DOUBLER AT FRAME 19, LEFT SIDE. BLENDED THE CORROSION AND FOUND BE OUT OF ALLOWABLE LIMITS IAW SRM 51-75-16. REPAIRED IAW ETD2017-170-074721.SDR IXXA20171006294Window Frame · corrodedUPPER CARGO R3 WINDOW FRAME HAS A CORROSION. REMOVED AND REPLACED THE WINDOW FRAME IAW SRM 51-40-02, PARAGRAPH 4, AND DRAWING 144N3200.SDR R61A201709170703Closeout Panel · corrodedAFT CARGO CUTOUT CLOSE-OUT PANEL HAS CORROSION. FOUND CLOSEOUT BEAM CORRODED OUT OF LIMITS. REMOVED AND REPLACED CLOSEOUT BEAM IAW AMM 20-10-01.SDR AALA201709019015Stop · wornAIRCRAFT IN BASE MAINTENANCE. WEAR ON FORWARD GALLEY PASSENGER CREW DOOR 831 FORWARD DOOR STOP POSITIONS 2, 3, 4, AND 5. REPLACED DOOR STOP SCREWS PER AMM 52-11-31-400-002-A AND 52-11-00-820-001-A.SDR IXXA20170830318Window Frame · corrodedUPPER CARGO WINDOW FRAME L16 CORRODED ON THE LOWER SURFACE AREA. REMOVED AND REPLACED THE WINDOW FRAME IAW SRM 51-40-02, PARAGRAPH 7, AND DRAWING 144N3200.SDR DALA2017083106473Door Frame · corrodedMID CARGO DOOR FRAME CORRODED JUST IN FRONT OF THE LOWER AFT DOOR FRAME STOP. REMOVED DAMAGE AND REPAIRED IAW SRM 53-05, FIG 123, OPTION 2.SDR VNAA2017082999914Post · crackedBS 409+128 VERTICAL POST AT LBL 27 INBD BOTTOM CRACKED AT BOTTOM FASTENER. REMOVED & REPLACED THE VERTICAL POST IAW SRM 51-42-06, 51-42-22, AND REO 601R-53-41-2217.SDR SWIA2017100243806Pressure Deck · corrodedRIGHT PRESSURE FLOOR BS 520 HAS CORROSION. REMOVED THE CORROSION IAW REO AND SRM.SDR EE4Y2017090304260Web · corrodedDURING A STRUCTURAL INSPECTION AT THE LT MAIN WHEEL WELL, FOUND SIDE WEB CORRODED, BS 695 - 706, STRINGER 18AL. THE WEB WAS REPLACED IAW SRM 51-10-02, PARAGRAPH 8, DRAWINGS 69-78163, AND 65-46877.SDR AALA201709269030Fitting · crackedCRACK ON NOSE FUSELAGE WINDSHIELD FRAME LT CONTINUITY FITTING, BL 0, BETWEEN FRAMES 1 AND 2. REPAIRED THE CONTINUITY FITTING IAW EA 272404.SDR ASAA2017082621917Web · gougedLOWER FUSELAGE E/E DOOR CUTOUT LT WEB GOUGED. ACFT GROUNDED. THE WEB FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-3. REMOVED DAMAGED WEB IAW SRM 51-40-02. FABRICATED THE WEB IAW DWG 141A8512, REV J. APPLIED ALODINE IAW AMM 51-21-41 AND DWG 141A8512. PRSDR JR2R20170826108Beam · corrodedAFT CARGO DOOR OPENING, LOWER BEAM HAS CORROSION BETWEEN FS 1155 TO 1212.SDR SWAA2022020109412Intercostal · crackedSUPPLEMENTAL INFORMATION: INTERCOSTAL AT BS328 - BS344 LBL46 IS CRACKED / REMOVED AND REPLACED INTERCOSTAL AT BS 328 - BS 344 LBL46 IAW SRM 51-40-02-0G-0 AND DWG 141A5410 SH 16. 57232U 25AUG17.SDR FDEA201708252357Beam · crackedSTUB BEAM AT BS 580 IS CRACKED. REMOVED AND REPLACED STUB BEAM IAW SRM 51-40-02-0G, AND DWG 657N4311, REV -.SDR SWAA2022020133682Panel · pulledSUPPLEMENTAL INFORMATION: CABIN FLOOR PANEL BREAK LOCATED AT STA 540 BETWEEN LBL 24 AND LBL 45. UPPER WEB HAS PULLED AWAY FROM CHANNEL. / REMOVED AND REPLACED PANEL BREAK ASSY. IAW SRM 51-40-02 AND BOEING DWG # 143A0060 REV O.SDR SWAA2022020133681Plate · pulledSUPPLEMENTAL INFORMATION: CABIN FLOOR PANEL BREAK LOCATED AT STA 540 BETWEEN LBL 45 AND CREASE BEAM. UPPER WEB HAS PULLED AWAY FROM CHANNEL. / REMOVED AND REPLACED PANEL BREAK PLATE IAW SRM 51-40-02-0G-0 AND DWG # 143A5240 REV 0. PW0131SDR SWAA2022020108494Intercostal · crackedSUPPLEMENTAL INFORMATION: PASS CABIN FLOOR; 3 CRACKS AT FASTENER HOLES ON UPPE R FLANGE OF INTERCOSTAL BETWEEN BS 5OOD AND BS 520. AT BL0. / REMOVED; LOCATED AND CRILLED AND INSTALLED NEW ANLGE AT PASS CABIN FLOOR STA: 500D AND 520 BL-O; AND APP LIED CIC AREA SDR V0XD20170830002Door Frame · corrodedPASSENGER DOOR FWD FRAME ACCESS PANEL 832CL HAS SIGNS OF CORROSION ON UPPER INTERNAL FOOT (FORMER). CORRECTIVE ACTION: CLEANED AND EVALUATED FORMER AND FOUND DAMAGE TO BE OUT OF LIMITS IAW CRJ700 SRM 51-26-00/53-00-00. REMOVED AND REPLACED FWD FORMER IAW CRJ70SDR SWAA2022020141648Strip · corrodedSUPPLEMENTAL INFORMATION: AFT CARGO FLOORBOARD TRANSITION STRIP AT STA 887 IS CORRODED BETWEEN PANEL 140CF AND 140DF / REMOVED AND REPLACED TRANSITION STRIP PER SRM 51-40-02 ALSO DISPLACED AND REPLACED PANEL 140CF AND 140DF PER AMM 25-52-10SDR SWAA2022020108457Intercostal · crackedPASSENGER CABIN INTERCOSTAL CRACKED AT STA 328-12' RBL 31. / REMOVED CRACKED INTERCOSTAL AT STA 328-12'; DRILLED AND INSTALLED NEW NACHINED INTERCOSTAL I/A/W BOEING DRAWING 141A5410; REVA AND B737 SRM 51-40-02; PARA 7.D. INSTALLED 2 EA NUTPLATES FOR FLOORBOARDSDR SWAA2017090516102Crease Beam · corrodedLT AFT CREASE BEAM CORRODED BETWEEN BS 947 TO BS 987. R&R CREASE BEAM IAW SRM AND DWG.SDR SWAA2022020112563Panel · corroded***CORROSION*** AFT CARGO COMPARTMENT (BS 727D +10 TO BS 787 + 6 LBL 20 ) TRANSITION PANEL IS CORRODED AROUND NUTPLATE HOLES IN 13 AREAS MARKED IN RED. / REMOVED CORROSION FROM AFT CARGO COMPARTMENT TRANSITION PANEL AROUND NUT PLATE HOLES IN A .7' X 1.5' X .00SDR SWAA2017091816364Crease Beam · corrodedAFT GALLEY DOOR CREASE BEAM CORRODED ON UPPER AND LOWER SURFACE. R&R CREASE BEAM IAW DWG AND SRM.SDR UIEA2017082901573Heat Shield · tornNR 2 PACK INBD HEAT SHIELD FOUND TORN. REPAIRED IAW RI-53-49-12019, REV A.
Back to JASC 5310