JASC 5310
Service difficulty reports · 38,573
Reports filed under 5310 · Fuselage Main, Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5310' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA111791Crease Beam · corrodedDURING SCHEDULED 12Y CHECK, FOUND AFT GALLEY CREASE BEAM CORRODED. REPAIRED BEAM PER SRM.SDR SWAA111790Crease Beam · corrodedDURING SCHEDULED 12Y CHECK, FOUND R1 DOOR CREASE BEAM CORRODED. REPAIRED BEAM PER SRM.SDR SWAA111911Web · crackedDURING SCHEDULED 22Y CHECK, FOUND CRACKS AROUND FLIGHT DECK FLOOR WEB STA 244 & 248, RBL 17 & 23. REPAIRED FLOOR WEB PER ACO.SDR UALA2011031401188Door Frame · crackedRIGHT OVERWING SLIDE BLOW OUT DOOR AFT FRAME AREA 2 CRACKED 6 INCHES. CARRIED FWD PER MT TO BE RECHECKED EVERY 3 SVC, CRACK WITHIN LIMITS 6 INCHES AT THIS TIME. ACP PER MT 25-018. CRACK IS WITHIN LIMITS AREA 2.SDR SWAA111840Door Frame · crackedDURING SCHEDULED 18Y CHECK, FOUND CRACK AT STA 957, WL 211 IN HOLE FOR L2 DOOR CUTOUT STUB FRAME. REPAIRED PER EA.SDR SWAA111666Crease Beam · corrodedDURING SCHEDULED 16Y CHECK, FOUND CREASE BEAM CORRODED BETWEEN BS 727B TO BS 727C, STR 17R. REPAIRED BEAM PER DWG.SDR SWAA111663Door Frame · crackedDURING SCHEDULED 16Y CHECK, FOUND AFT CARGO DOOR FRAME CRACKED ON AFT LOWER CORNER. REMOVED AND REPLACED FRAME PER BAC DWG.SDR V0XR201103110008Beam · corrodedCTR BEAM AT Y0.0 FR 58-63 IS CORRODED BEYOND LIMITS. R & R BEAM.SDR COEA2011031139805Crease Beam · corrodedHEAVY CK COE / MAJOR REPAIR / LEVEL 2 CORROSION: LT CREASE BEAM WEB FR 17 - 18 HAS AREAS OF LEVEL 2 CORROSION (LENGTH 1.6", WIDTH 1.1", DEPTH .012"). REMOVED LT CREASE BEAM WEB AND CORROSION; FABRICATED AND INSTALLED NEW LT CREASE BEAM WEB PER ATR72 SRM.SDR AALA20110311TUL10Pan · crackedWINDOW PAN UPPER AFT TAB CRACKED AT LEFT STATION 1041. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR AALA20110311TUL09Pan · crackedWINDOW PAN UPPER AFT TAB CRACKED AT LEFT STATION 1022. INSTALLED REPAIR DOUBLER REF AARD 53-10-00-25.SDR AALA20110311TUL08Pan · crackedWINDOW PAN UPPER FORWARD TAB CRACKED AT LEFT STATION 886. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR AALA20110311TUL05Pan · crackedWINDOW PAN UPPER AFT TAB CRACKED AT LEFT STATION 1060. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR USAA2011033191295Door Frame · crackedCLT - Q5/QX6 - CRACK ON STUB FRAME LOCATED FORWARD OF FORWARD SERVICE DOOR AT BS291.5, S11R. REPLACED STUB FRAME LOCATED FORWARD OF FORWARD SERVICE DOOR AT BS 291.5, S11R IAW B737 SRM 51-40-02 & BOEING DRAWING 65-45807.SDR FDEA201103100933Crease Beam · corrodedCABIN, CREASE BEAM AT BS 800, RBL 64, HAS SURFACE CORROSION. EVALUATE AND RECTIFY. EA F-5310-145321, FUSELAGE-MAINFRAME-CREASE BEAM INBD CHORD REPAIR AT RBL 64, BETWEEN BS 780 TO BS 800 PART 1 CARRIED OUT. THIS REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-1- CSDR UALA2011031001161Door Frame · damagedRIGHT OVERWING EMERGENCY SLIDE BLOW OUT DOOR FRAME SPLIT AND BENT. DAMAGE APPROX 9 INCHES LONG LOWER AFT SECTION OF DOOR FRAME. REPLACED RIGHT OVERWING SLIDE PER AMM. ACCOMPLISHED FINAL INSTALLATION PER MM AND METHOD 4 OF THE RII LIST.SDR V0XR201103090004Beam · crackedLT BEAM AT FR 53-59 LY 479.0 IS CORRODED BEYOND LIMITS. R & R BEAM.SDR SWAA111833Door Frame · crackedDURING SCHEDULED 22Y CHECK, FOUND CABIN OVERWING ESCAPE HATCH DOORWAY FRAME STA 639, 2 INCHES ABOVE STR 17L FRAME WEB CRACKED. REMOVED AND REPLACED FRAME WEB ASSY PER SRM.SDR AALA20110309TUL02Pan · crackedWINDOW PAN CRACKED AT LOWER FORWARD TAB LEFT STATION 1060. INSTALLED REPAIR ANGLE PER AARD 53-10-00-25.SDR 1MUR20110308001Shear Web · corrodedL2 DOOR HAS CORROSION AT AFT LOWER DOOR FRAME WEB AT STN NR 1006 LOCALIZED LEVEL II CORROSION NOTED.SDR IPXA11565620Door Frame · gougedINSPECTION TYPE:C3, MAIN CARGO DOOR FRAME HAS A SCREW STRIKE BS 613, 5 INCHES ABOVE THE LOWER BEAM. R & R IAW DWG 69-24182 AND SRM 51-40-02.SDR ASOA201100454Structure · corrodedCORROSION IN BELLY OF FUSELAGE IN AV BAY BETWEEN FS 349 AND 364 BETWEEN STR 25L AND 26L. REPAIRED IAW REO 670-53-21-662.SDR DALA1116579011Window Frame · damagedTOOL MARKS ON WINDOW FRAME UPPER SECTION FROM STA Y=845 TO 864 AT FUSELAGE SKIN LEFT SIDE. REPAIRED PER ERA 490025-14.SDR MALA110056Door Frame · dentedDENT ON UPPER RT SIDE MAIN CABIN DOOR FRAME, APPROX 4 INCHES FROM TOP. PERFORMED TEMPORARY REPAIR TYPE II OF DENT ON UPPER RT SIDE MAIN CABIN DOOR FRAME APPROX 4 INCHES FROM TOP IAW REO 670-53-22-011. TEMP REPAIR GOOD FOR 400 FLIGHT HOURS, APPROX 8 MAN HRS TSDR MALA110055Door Frame · gougedDOOR FRAME UPPER AFT GOUGED. REPAIRED AFT UPPER DOOR SEALS USING REO 670-53-22-001 TYPE 1 AS REF.SDR DALA1116509870Door Frame · bentFUSELAGE EXTERIOR STA 1068 BETWEEN L23R AND L24R PREVIOUS REPAIR AT AFT CARGO DOOR JAMB BENT. REMOVED & REPLACED PREVIOUS REPAIR IAW SRM 51-30-2 & 51-30-5. FABBED NEW DOUBLER. LOCATED, DRILLED & DEBURRED IAW SRM 51-10-2 & 51-10-4. ALODINED & PRIMED IAW SRMSDR DALA1116289877Pan · crackedCRACK IN DOOR PAN STRUCTURE JUST OTBD OF SAFETY HOOK. STOP DRILLED CRACKS IN DOOR PAN IAW SRM 51-01, PG2, HFEC SURFACE INSP GS 24, 26B & 2001 NO CRACKS PASS STOP DRILL, FABRICATED REPAIR DOUBLER, IAW SRM 52-05 AND SRM 51-10-2. LOCATED & DRILLED REPAIR DOUBLERSDR ZZDA2011267Door Frame · crackedMAIN CABIN LT FWD ENTRY DOOR JAMB, STA 205, LONG 15, CRACKED. ACCOMPLISHED ENTRY DOOR JAMB DOUBLER REPAIR PER B717 SRM 51-70-10 AND B717 SRM 51-41-02.SDR AALA20110308TUL07Pan · crackedRIGHT WINDOW PAN CRACKED AT UPPER FORWARD SIDE AT STATION 927. REMOVED CRACK BY ROUTING PER AARD 53-10-00-25 AND INSTALLED REPAIR DOUBLER CDK 3488-2 PER AARD 53-10-00-25.SDR AALA20110308TUL06Pan · crackedRIGHT WINDOW PAN CRACKED, UPPER FORWARD SIDE AT STATION 946. REMOVED DAMAGE BY ROUTING PER AARD 53-10-00-25 AND INSTALLED REPAIR DOUBLER CDK 3488-2 PER AARD 53-10-00-25.SDR UHLA2011030700122Crease Beam · corrodedLEVEL 2 CORROSION CREASE BEAM LT SIDE AT FR 90. REMOVED AND REPLACED NEW CREASE BEAM PANEL SUPPORT IAW EMB 170 SRM 51-40-02, 51-41-01, 51-42-01.SDR ASOA201100442Crossbeam · corrodedFS 280 CROSSBEAM CORRODED. INSTALLED CROSSBEAM REF SRM 51-42-13-001-001SDR A6WA201140219Housing · damagedDAMAGE TO POWER RECEPTACLE (A/C) HOUSING AND STRUCTURE ASSY. REPAIR IAW REO 601R-53-11-2081.SDR IPXA11565472Beam · damagedINSPECTION TYPE:C3, MCB LONGITUDINAL BEAM HAS MECH DAMAGE ON UPPER SURFACE ADJACENT TO SEAT TRACK, BS 1040-1074, LBL 24, WL MARKED. REPLACED LONGITUDINAL BEAM IAW SRM 51-21-04-7, SRM 51-40-02-0G, SRM 53-40-51-0I.SDR IPXA11565471Beam · damagedINSPECTION TYPE:C3, LONGITUDINAL BEAM HAS MECHANICAL DAMAGE BS 1054 TO 1073, RBL 25.5. R & R WITH NEW PART IAW DWG NR144N8017 AND SRM 51-40-02-0G.SDR IPXA1565438Beam · damagedINSPECTION TYPE:C3, LONGITUDINAL BEAM HAS MECHANICAL DAMAGE BS 1054 TO BS 1073, RBL 44.5. REPLACED PART IAW SRM 51-40-02 & DWG 144N8017.SDR DALA1115519877Structure · crackedOVERSIZED RIVNUT HOLE ON AFT SIDE OF FWD CARGO DOOR IS MISSING RIVNUT AND HOLE IS CRACKED. FABRICATED REPAIR DOUBLER IAW SRM 52-03, FIG 1. ALODINED REPAIR DOUBLER IAW SRM 51-10-3, PARA 21. PRIMED REPAIR DOUBLER IAW SRM 51-10-3B, PARA 2 F . INSTALLED REPAIR SDR V0XR413Y030511002Crossbeam · corrodedRT WEB AT 280.00 CROSSBEAM CORRODED. R & R SILL FS 280.00 RT IAW REO 670-53-21-659 AND SRM 51-42-06 AND 51-42-13.SDR V0XR413Y030511001Crossbeam · corrodedFS 280 CROSSBEAM CORRODED. REMOVED AND INSTALLED CROSSBEAM FS 280.00 IAW REO 670-53-11-351, REV D.SDR COEA2011041419903Crease Beam · corrodedHEAVY CHECK / COE / CORROSION LEVEL 2: REMOVED CORROSION IAW ATR 42 SRM. REMAINING MATERIAL THICKNESS FOUND TO BE OUT OF LIMITS. REMOVED WEB, LOCATED, MATCH-DRILLED AND DEBURRED NEW WEB. INSTALLED WEB, LT CREASE BEAM WEB 17 - 18.SDR IPXA1565839Door Frame · damagedINSPECTION TYPE:C3, MAIN CARGO DOOR, MECHANICAL DAMAGE ON FRAME BS 529, WL 217, AND 222. REPAIRED FRAME IAW ER NR 11-01807 AND UPS EO B757-5230-42080-A.SDR DALA1115749877Door Frame · crackedAFT CARGO COMPT LOWER JAMB AT STA 1068 AND STR 28R STRINGER CLIP CRACKED. REMOVED 2 EA SPLICE REPAIR AND 1 EA TEE BRACKET AT STA 1068 AND 28R AFT5 CARGO IAW SRM 51-30-15, PG 29. REMOVED 1 EA CRACKED CLIP IAW SRM 51-30-15, PG 29, LOCATED AND DRILLED NEW STR CSDR V0XR201103030013Angle · corrodedANGLE AT FR 24 IS CORRODED. REMOVED AND REPLACED ANGLE.SDR V0XR201103030004Support · corrodedSERVICE DOOR FWD SILL IS CORRODED BEYOND LIMITS. REMOVED AND REPLACED SILL.SDR CHQA201100098Door Frame · corrodedDURING INSPECTION CORROSION WAS FOUND ON THE SERVICE DOOR SURROUND LOWER PORTION AT FRAME NR 22. A THICKNESS MEASUREMENT WAS DONE BY UT IAW NDI MANUAL, INTRODUCTION P 22 (F). MINIMUM MATERIAL REMAINING IS 0.22 INCHES. A HIGH FREQUENCY EDDY CURRENT INSPECTIOSDR SWAA111338Crease Beam · crackedDURING SCHEDULED 24Y CHECK, FOUND CREASE BEAM WEB CRACKED BETWEEN BS 907 TO BS 927, STR 17L. REMOVED AND REPLACED WEB PER SRM AND BAC DWG.SDR ASAA1149128Crease Beam · corrodedAFTER REMOVAL OF PARTS TO ACCESS FLOORBEAM REPAIR AT BS 986 FOUND CORROSION ON CREASE BEAM WEB AT BS 1008 RBL 42. REMOVED CORRODED WEB FABRICATED REPLACEMENT PART AND INSTALLED IAW B737 400 SRM 51 40 05 AND 51 40 02.SDR CA110307004Beam · cracked(CAN) ONE INCH CRACK IS LOCATED ON BEAM ASSY LOCATED ON AFT SIDE OF LT WHEEL WELL AREA.SDR CHQA201100096Window Frame · damagedDURING INSPECTION THE TOP WINDSHIELD CUT OUT STRUCTURE WAS FOUND TO BE DAMAGED AT THE RIGHT FAIRING ATTACHMENT BRACKET. EDDY CURRENT INSPECTION CARRIED OUT ON LEFT BLEND IAW NDI MANUAL, INTRODUCTION P 17, NO CRACK FOUND. THE TOP WINDSHIELD CUTOUT STRUCTURE ASDR CHQA201100095Window Frame · damagedDURING INSPECTION THE TOP WINDSHIELD CUTOUT STRUCTURE WAS FOUND TO BE DAMAGED AT THE LEFT FAIRING ATTACHMENT BRACKET. EDDY CURRENT INSPECTION CARRIED OUT ON LEFT BLEND IAW NDI MANUAL, INTRODUCTION P 17, NO CRACK FOUND. THE TOP WINDSHIELD CUT OUT STRUCTURE AT
Back to JASC 5310