JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA202264865Frame · corrodedUNDERFLOOR CORROSION.FRAME FS319.7 CORRODED BETWEEN STRINGERS 18L TO 21L. (C-CHECK RO 3/11/2022) REMOVED AND INSTALLED NEW REPLACEMENT FRAME (P/N SH670-31891-3S) AT FS319.70 BETWEEN STGR'S 18L AND 21L. REF BOMBARDIER DWG# SH670-31810 REV AE, CRJ700 SRM SDR SWIA202264525None · crackedLH STIFFENER IS CRACK COMMON TO FLOOR BEAM AT LBL 12 FS274 (C CHECK RO 2/17/2022) REMOVED AND REPLACED LH STIFFENER COMMON TO FLOOR BEAM AT LBL12 FS274 REF SRM 51-42-06-001-001-A01, BOMBARDIER DRAWING CC670-33199 REV -B, DRAWING CC670-33052 REV -G. COMPLISDR R61A2022020500105Shear Tie · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION FOUND CORROSION FOUND ON FWD FUSELAGE SHEAR CLIP AT FR17 BETWEEN STGR 27R AND STGR 28R. SHEAR TIE CLIP ON FR17 BETWEEN STRINGER 27R AND 28R ON FWD FUSELAGE WAS REMOVED AND REPLACED IAW SRM 51-41-02.SDR SWAA2022013162128Angle · crackedOUTFLOW VALVE LATCH BASE ANGLE IS CRACKED P/N 216A9472-2 BS 982 OUTBD OF STR 23R ; / [01] REMOVED BASE ANGLE IAW SRM 51-40-02; RECEIVED NEW BASE ANGEL ITEM: 216A9472Y5 LOT: 1479399-1; LOCATED AND DRILLED NEW BASE ANGLE IAW SRM 51-40-05. OK TO INSTALL; [02] REMSDR R61A2022012900073Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK, CORROSION FOUND ON FWD FUSE SHEAR TIE CLIP AT FR 17 BTWN STR 28-29. MX REPLACED SHEAR CLIP PN 170-03335-001 IAW SRM 51-41-01, 51-41-02, 51-43-03. FOR DETAILS OF WORK PERFORMED. AC REMAINS IN YQG FOR COMPLETIONSDR DALA2022011900362None · noneSHIP 6822 AWR. AD. A.A 5311-01227-02B EXISTING REPAIR WAS FOUND IN THE INSPECTION AREA AT STA 1300 AND S-26R. CORRECTIVE ACTION: SUMMARY OF NRC 00205. EXISTING REPAIR ON STA 1300 AND S26R WAS INSPECTED AND EVALUATED, LFEC INSPECTION WAS PERFORMED AROUND SIDEWASDR SWIA202264155None · damagedCUT AND REPAIR FS 319.00 FRAME BETWEEN STR 25L TO STR 25R TO PERFORM REMOVE AND REPLACE STR 25R BETWEEN FS280.00 TO FS333.00 (C CHECK RO 02-03-22) REPAIRED FS 319.00 FRAME BETWEEN STR 25L TO STR 25R IAW CRJ 700 SRM 53-00-06-201-006-A01. COMPLIED WISDR AALA202201189566Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT FR 43 BETWEEN S18R AND S24R. REPLACED FRAME PER EA 333011.SDR DALA2022011700307None · noneSHIP 3261 FWD L-1 DOOR, FWD UPPER CORNER DOOR CUTOUT (DOOR STOP 7), FR16 AT DOUBLE JOGGLE AREA IN OUTER FLANGE OF FRAME, FWD FASTENER ROW 3RD FASTENER HOLE FROM TOP (HOLE#5) HAS CRACK INDICATION APPROXIMATELY 7 OCLOCK POSITION AS VIEWED FROM INSIDE THE AIRCRAFSDR DALA2022011700306None · noneSHIP 3261 CRACK INDICATION NOTED ON LH FR 20 DOOR STOP #7 AREA AT HOLE #8. CORRECTIVE ACTION: COMPLIED WITH ER/A 595833-14AD REV ORIGINAL. (2088331)SDR CALA2022011700163Fastener · crackedDOUBLE JOGGLE FASTENER HOLES LHFR20 TOP HOLES AFT ROW, HOLE A HA S A CRACK INDICATION, MUST BE REPAIRED BEFORE NEXT FLIGHT PER EA 5311-02442. REPAIRED L/H FR20 DOUBLE JOGGLE FASTENER HOLES IAW EC/RA 5311-02 726. SEE DTA DIP LP# 7802054 FOR INSPECTION REQUIREMESDR SWIA202265331None · corrodedFOUND MULTIPLE AREAS OF CORROSION ON RBL 27 FS 1031-1051 (C-CHECK RO 4/9/2022) REPAIRED FLOORBEAM ON RBL 27 FROM FS 1031-1051 IAW CRJ 700 SRM 53-00-41-201-001-A01. MAJOR REPAIR TASK CARD 51-900-1002-SKY AND FORM 337 COMPLETED AND ATTACHED. WEIGHT CHANGSDR SWIA202264712None · corroded*PASSENGER DOOR €“ CORROSION ON FORMER AT FS329.41 BETWEEN DD5 AND DD6. (C CHECK RO 02/25/2022) BLENDED OUT CORROSION AND RESTORED FINISH ON FORMER AT FS329.41 BETWEEN DD5 AND DD6. REF: CRJ-700 SRM 51-21-06-001-001-A01 / AND CRJ-700 SRM 51-25-16-001-001-ASDR SWAA2022013161495Shear Tie · crackedBS 967 FRAME SHEAR TIE P/N 147A1120-57 IS DAMAGED. REMOVED SHEAR TIE AT ACB FRAME BS 967 STR 25L - STR 26L LBL 15. SHEAR TIE FOUND TO BE OUT LIMITS WILL BE REPLACED IAW SRM 51-10-02-0G-0 STEP 9 C. LOCATED AND DRILLED NEW SHEAR TIE IAW SRM 51-40-05. INSTSDR CALA2022011700155Support · damagedTRANSCRIBED FROM HAECO GSO NR LP 9287333 B757-06-3-0244 STATION 1380 FRAME INNER CHROD AT S-27R REQUIRES REPAIR PER ECRA 5360-01624: "PERFORM AN INSPECTION PER THE LATEST REVIS ION OF ECRA 5360-01624 PART 2 ON OR BEFORE 22-MAY-2023" DIP INITIATED, PERFORM INSPSDR SWIA202264896None · corrodedF.S.349 FLOOR BEAM UPPER FLANGE IS CORRODED AT APPROX. RBL 42 (C CHECK RO 3/11/2022) REMOVED DAMAGED SECTION OF FLOOR BEAM AT FS 349 AND INSTALLED A NEW SECTION IAW CRJ 200 SRM 51-42-06, 51-42-21, AND 51-42-13 REV.38B, DATED 11/25/2020 WITH REO 601R-53-21-SDR SWIA202264887None · corrodedF.S.280 CROSSBEAM UPPER FLANGE IS CORRODED BETWEEN RBL 9 AND LBL18 (C CHECK RO 3/11/2022) REMOVED OLD DAMAGED AND LOCATED, DRILLED AND SHOT NEWFS 280 CROSS BEAM UPPER FLANGE BETWEEN RBL9 AND RBL 8 IAW SRM 51-42-06 AND SRM 51-40-11 REV 38 B DATED 25 NOV 20SDR SWIA202264885None · corrodedF.S.349 FLOOR BEAM UPPER FLANGE IS CORRODED AT APPROX. LBL 42. (C CHECK RO 3/11/2022) FS 349.00 CROSSBEAM REPAIR WAS ACCOMPLISHED IAW MHIRJ REO 601R-53-21-3524 REV -- DATED 2022-02-24 WITH NEGLIGABLE CHANGE TO WEIGHT AND BALANCE, M-337 AND TASK CARD 51-900SDR SWAA2022021461332Frame · corrodedCORROSION ON FRAME LOCATED BS 351.2 AND LBL 62; WL 208.1 PAX CABIN ; 2022-11480 / [01] TOOL USED THICKNESS GAUGE P/N: 45MG; S/N: 130060401; DUE DATE: 22-APR-22.; [02] TOOL USED PN NORTEC 600D SN 200048001 DUE DATE 24-FEB-22; [03] REPAIRED FRAME LOCATED BS 351.SDR R61A2022020500106Shear Tie · corrodedDURING HEAVY CHECK MAINTENANCE FOUND CORROSION FOUND ON AFT CARGO SHEAR CLIP AT FR75 BETWEEN STGR 28R AND STGR 29R. CORROSION FOUND ON AFT CARGO SHEAR CLIP AT FR75 BETWEEN STGR 28R AND STGR 29R REMOVED AND REPLACED WITH FABRICATED PART IAW EMB SRM 51-42-00.SDR R61A2022020100086Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND CORROSION FOUND ON AFT CARGO FLOOR SUPPORT CLIP AT FR 80 BTWN STGR 27R-28R. MX REPLACED SUPPORT CLIP PN 170-87229-001 IAW SRM 51-41-01, 51-41-02. AC REMAINS IN YQG FOR COMPLETION.SDR R61A2022020100085Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUNDCORROSION FOUND ON ACFT CARGO SHEAR CLIP AT FR 86 BTWN STRG 27L STGR 28L. MX REPLACED SHEAR CLIP PN 170-66029-001 IAW SRM 51-43-01, 51-41-02. AC REMAINS IN YQG FOR COMPLETION.SDR R61A2022020100084Angle · corrodedWHILE AC WAS IN FOR HVY CK FOUND CORROSION FOUND ON AFT CARGO FLOOR STRUCTURE SUPPORT ANGLE AT FR81 AND STR 28R. MX REPLACED STABILIZER PN 170-85691-001 IAW SRM 51-43-03 AC REMAINS IN YQG FOR COMPLETION.SDR JJBA202201183017Frame · damagedFRM 69 HAS DAMAGED NUT PLATE AND ELONGATED HOLE AT STGR 7R. REMOVED DAMAGE HOLE FINAL SIZE D=0.252" AT FRAME 69 STR 7R. FOUND TO BE IN LIMITS.SDR CALA2022011400141Shear Tie · damagedSHEAR TIE DAMAGED AT STA.420 BETWEEN S-20L AND S-21L. VERIFIED SHEAR TIE PER AVO 713-22-01-06-01 REV. C. STEP B.3.. OK TO CONTINUE. MGH QC775 VERIFIED SHEAR TIE PER AVO 713-22-01-06-01 REV. C. STEP B.3. VERIFIED REFORM OF SHEAR TIE. PERFORMED HFEC OF REWORKEDSDR CALA2022011400133Frame · crackedDOUBLE JOGGLE FASTENER HOLES LHFR20 TOP HOLES AFT ROW, HOLE A HA S A CRACK INDICATION, MUST BE REPAIRED BEFORE NEXT FLIGHT PER EA 5311-02442.SDR DALA2022011800336None · noneSHIP 6822 REPAIR TO FUSELAGE BS 1300 FRAME INBOARD CHORD BETWEEN S-24R & 28R REQUIRES SUPPLEMENTAL INSPECTIONS PER ERA 544742-14AD REV A. CORRECTIVE ACTION: REF ERA 544742-14AD REV A. (2084163)SDR CALA2022011400126Intercostal · crackedL1 DOOR FRAME 16 STOP #7 INBOARD LOWER HOLE IS CRACKED IN THE IN TERCOASTAL AT 5 O''CLOCK AND THE INBOARD UPPER HOLE IS CRACKED IN THE WEB AT 11 O''CLOCK AND INTERCOASTAL AT 5 O''CLOCK. SUPPORT TASK AD 2019-20-10 GENERATED BY V061633 AT HAECO LCQ PER NON ROUTISDR DALA2022011300263None · noneSHIP 3267 NEED TO PERFORM IN FRAME 4 R/H VA 99150 REV B IN CONJUCTION WITH JOB CARD 531 6-01052-01B IN COCKPIT. (CRACK). CORRECTIVE ACTION: COMPLIED WITH DELTA CARD AMDS 5316-01052-01B. (2083832)SDR DALA2022011300262None · noneSHIP 3267 NEED TO PERFORM PERFORM IN FRAME 4 LH VA 99150 REV B IN CONJUCTION WITH JOB CARD 5316-01052-05A IN COCKPIT. (CRACK). CORRECTIVE ACTION: COMPLIED WITH DELTA WORKCARD 5316-01052-05A. (2083822)SDR SWIA202265325None · corrodedFRAME AT FS 1000 IS CORRODED BETWEEN STGR 27-26L (C-CHECK RO 4/9/2022) REPAIRED FS1000 FRAME IAW MHIRJ REO 670-53-61-2059 REV-- DATED 2022-02-14. SKYWEST MAJOR REPAIR TASK CARD 51-900-1002-SKY COMPLIED WITH. REFERENCE CONTINUATION CARD FOR WORK PERFORMESDR SWIA202265323None · corrodedF.S. 364 FRAME IS CORRODED BETWEEN STGR 26L TO 25L. (C-CHECK RO 4/9/2022) REPAIRED FRAME AT F.S 364 BETWEEN STGR26L TO 25L IAW MHI REO # 670-53-21-687 REV-A DATED 2016/06/06 AND SKYCARD 51-900-1002-SKY.NO CHANGE TO WEIGHT AND BALANCE. REF CONTINUATIONSDR SWIA202265320None · corrodedF.S. 349 FRAME IS CORRODED BETWEEN STGR 27 TO 26R. (C-CHECK RO 4/9/2022) REMOVED AND REPLACED FS 349 LOWER FRAME SEGEMENT IAW CRJ 700 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01 REV.38B DATED 14 DEC 2020. MAJOR REPAIR TASK CARD 51-900-1002-SKY ANDSDR SWIA202265316None · corrodedF.S. 319 FRAME IS CORRODED BETWEEN STGR 26L TO 26R. (C-CHECK RO 4/9/2022) REPAIRED F.S. 319 FRAME BETWEEN STR 25L AND STR 23R IAW CRJ 700 SRM 53-00-06-201-006-A01 REV. 38B DATED 14 DEC 2020. MAJOR REPAIR TASK CARD 51-900-1002-SKY AND FORM M-337 COMPLETESDR SWIA202265313None · corrodedF.S. 310 FRAME IS CORRODED BETWEEN STGR 25L TO 26R. (C-CHECK RO 4/9/2022) FS 310.00 FRAME WAS REPAIRED IAW CRJ 700 SRM 53-00-06-201-006-A01, NO CHANGE TO WEIGHT ANDE BALANCE. M-337 AND TASK CARD 51-900-1002-SKY ATTACHEDSDR SWIA202265312None · corrodedFRAME AT FS 1051 STRG 27 IS CORRODED (C-CHECK RO 4/9/2022) REPAIRED FRAME AT FS 1051.30 BETWEEN STR24L-STR24R IAW REO 670-53-61-2060 REV.-- DATED 2022-03-14. MAJOR REPAIR TASK CARD 51-900-1002-SKY AND FORM M-337 COMPLETED AND ATTACHED. NO WEIGHT CHANGE SDR SWIA202265310Frame · corrodedFRAME AT FS1051 IS CORRODED BETWEEN STRG 26L-26R (C-CHECK RO 4/9/2022) UPON FURTHER INVESTIGATION FOUND CORROSION TO BE AT FS 1015.00 BETWEEN 26L-26R. COMPLIED WITH MHIRJ REO 670-53-61-2062 REV.-- DATED 2022-02-22 FOR FRAME SPLICE REPAIR ON FRAME 1015.0SDR SWIA202264706None · corroded* FS 319.70 FRAME HAS CORROSION JUST ABOVE STGR 20L ON ITS FWD FACE AROUND A GROUND STUD, AND ON ITS LOWER ATTACH FLANGE DIRECTLY BELOW THE GROUND STUD (C CHECK RO 02/25/2022) REMOVED CORROSOION ON FRAME FS319.70 WITHIN LIMITS REF REO 670-53-21-2223 REV-- SDR N6WA2022011202Frame · corrodedCORROSION LEVEL 2 ON FS1047.00, REPLACE SECTION OF FRAME IAW CRJ 700 SRM 53-00-06, EO C550/700-53MR-058-O PER SECTION II OF EA 81-2021-099, PLACED ON CO 537983SDR MASA20220110028None · corroded"THE FUSELAGE FRAME AT FS 1088.20 WAS FOUND WITH CORROSION DAMAGE AT TWO LOCATIONS BETWEEN STGR 26R TO 26L. PERFORM PERMANENT REPAIR IAW CRJ7/9 SRM 51-00-00, THE FUSELAGE FRAME IS CLASSIFIED AS PRIMARY STRUCTURE.
2. PERFORM PERMANENT REPAIR IAW CRJ7/9 SRM 51SDR SWAA2022022159715Stub Frame · crackedCRACK SERVICE DOOR DOOR CUT OUT STUB FRAME LOCATED BS 294.5 AND BTW STR 7R AND STR 9R AT FWD GALLEY AREA 2022 15911 / [01] REPLACED STUB FRAME LOC. BS 294.5 BTW STR 7R TO STR 9R IAW B737-700 DWG 141A8370 SHEET 1 REV: C AND SRM 51-40-02 AND 51-10-02 PARAGRAPH 9SDR SWAA2022021559557Stub Frame · crackedCRACK STUB FRAME LOCATED BS 294.5 AND BETWEEN STR8R AND STR9R AT FWD GALLEY AREA ; 2022-12257 / [01] REPLACED STUB FRAME LOCATED BS 294.5 AND BETWEEN STR8R AND STR9R AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A8370 SHEET 9 AND 10 REV. D.; [02] CERSDR SWAA2022021559564Frame · crackedCRACK FRAME ON BS 947.5 AROUND FASTENER LOCATED RBL 8 AT AFT CARGO COMPARTMENT ; 2022-12261 / [01] REPLACED FRAME LOCATED AT BS 947.5 AND BTW STR 23R TO STR 23L IAW SRM B737-700 51-40-02 AND DWG 147A1047 REV:D; [02] REPLACED FRAME LOCATED AT BS 947.5 AND BTW SSDR SWAA2022021559568Frame · corrodedCORROSION FRAME ON BS 947.5 LBL 9 INCH WL 178 AT AFT CARGO COMPARTMENT ; 2022-12282 / [01] FAULT RESOLVED ON OTHER FAULT (TTG8Q00A70UJ); [02] FAULT RESOLVED ON OTHER FAULT (TTG8Q00A70UJ)<BR>SEE INDIVIDUAL SIGNOFFS BELOW; [03] FAULT RESOLVED ON OTHER FAULT (TTGSDR AALA202201108599Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FRAME LOCATED AT FR 43 FROM S18R TO S24R. REPLACED FRAME PER EA 332514 AND DWG R533-70232 REV. C.SDR SWIA202264703None · corroded*CORROSION ON FRAME FS 364.00 BETWEEN STGR 26L €“ 26R (C CHECK RO 02/25/2022) REPAIRED FRAME FS364.00 FROM STR 24L TO STR 24R. REF CRJ-700 SRM 53-21-23-201-008-A01. LEAK CHECK GOOD. OPS CHECK GOOD. COMPLIED WITH 51-900-1002-SKYSDR SWIA202264698None · corroded*CORROSION ON FRAME FS 333.00 BETWEEN STGR 26R €“ 25R (C CHECK RO 02/25/2022) INSTALLED NEW FRAME FS333.00 BETWEEN STGR 26R €“ 25R REF CRJ 700 SRM 51-42-21-001-001-A01, CRJ700 SRM 51-42-06-001-001-A01,DWG # SH670-31356. REV-NC AND DWG # SH670-32420 REV-SDR SWAA2022021159608Frame · crackedCRACK FRAME STUB LOCATED AT BS 294.5 LEVEL STR 9R CUT OUT SERVICE DOOR AT PASSENGER CABIN ; 2022-11263 / [01] APPLIED SEALANT BMS 5-95 CLASS C20 AND INSTALLED TEMPORARY FASTENER IN ALL HOLES ON STUB FRAME AT 14:15 PM HRS 20/JAN/22 WHITIN SQUEEZE OUT TIME. IAW SDR SWAA2022021159603Frame · crackedCRACK FRAME BS 312 LOCATED AT FWD UPPER CORNER OF FWD ENTRY DOOR CUTOUT AT PASSENGER CABIN ; 2022-11262 / [01] TOOL USED CALIPER P/N 500-196-30 S/N B21140348 DUE DATE 15-OCT-22; [02] TOOL USED EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022236 ; DSDR SWAA2022021159602Frame · crackedCRACK FRAME STUB LOCATED AT BS 294.5 LEVEL STR 17R CUT OUT SERVICE DOOR AT PASSENGER CABIN ; 2022-11261 / [01] TOOL USED EDDY CURRENT EQUIPMENT PN: NORTEC500D; SN: N500X12101V022235; DUE DATE: 03 JUN 22.; [02] PERFORMED PERMANENT REPAIR ON STUB FRAME LOCATED A
Back to JASC 5311