What was found
CRACK FRAME STUB LOCATED AT BS 294.5 LEVEL STR 9R CUT OUT SERVICE DOOR AT PASSENGER CABIN ; 2022-11263 / [01] APPLIED SEALANT BMS 5-95 CLASS C20 AND INSTALLED TEMPORARY FASTENER IN ALL HOLES ON STUB FRAME AT 14:15 PM HRS 20/JAN/22 WHITIN SQUEEZE OUT TIME. IAW BAC5000.; [02] REPLACED FRAME STUB LOCATED AT BS 294.5 LEVEL STR 9R CUT OUT SERVICE DOOR AT PASSENGER CABIN IAW DRAWING 141A8370 REV- AND SRM B737-700 51-10-02 Ï¿½TEM 9 SEE INDIVIDUAL SIGNOFFS BELOW.; [03] REPLACED FRAME STUB LOCATED AT BS 294.5 LEVEL STR 9R CUT OUT SERVICE DOOR AT PASSENGER CABIN IAW DRAWING 141A8370 REV- AND SRM B737-700 51-10-02 Ï¿½TEM 9.RII ;SEE INDIVIDUAL SIGNOFFS BELOW.