SDR DALA2021011100155Frame · crackedCRACK INDICATION ON FRAME 68 LT DOOR STOP 1 LOWER INBOARD HOLE. CORRECTIVE ACTION: PERFORMED REPAIR PER A320 SRM 53-41-12-300-010 RECHECK REQUIRED AT 37,700 FC.SDR DALA2021011100150Frame · crackedCRACK INDICATION ON FRAME 16 LT SIDE IN HOLE 3 AT LEVEL OF DOOR STOP FITTING. CORRECTIVE ACTION: PERFORMED REPAIR PER ERA 588771-14AD REV ORIGINAL.SDR DALA2021011100149Frame · crackedCRACK INDICATION FOUND IN HOLE 3 AT LEVEL OF DOOR STOP FITTING 1 AND FRAME 16 LT SIDE. CORRECTIVE ACTION: REPAIRED PER ERA 588771-14 AD REV 0, 1, 2 AND ER/A 588771-14AD REV ORIGINAL.SDR DALA2021011100148Frame · crackedCRACK INDICATION ON FRAME 68 RT DOOR STOP 1 LOWER INBOARD HOLE. CORRECTIVE ACTION: REPAIRED PER ER/A 588847-14AD REV ORIGINAL.SDR N6WA2021010903Angle · corrodedCORROSION ON FRAME 265 STIFFENING ANGLE STRG 25R-25L. R & R FRAME 265 STIFFENING ANGLE AT STR 25L-25R, IAW CRJ 550 SRM 51-42-06.SDR N6WA2021010901Frame · crackedFRAME 333 CRACKED AT TOP FROM LIGHTNING HOLE TO FREE FLANGE. REMOVED LOWER FREE FLANGE SUPPORT ANGLE ON FS 333 AT STR 0-2R. FABRICATED REPAIR PART AND INDTALL, PER REO 670-53-21-1913.SDR SWIA202156267Frame · corroded*CORROSION NOTED ON FRAME 319.70 BETWEEN STRG18L-20L (MARKED) (C-CHECK) RO 2/13/2021 REMOVED AND INSTALLED NEW FRAME (P/N SH670-31891-3) AT FS319.70 BETWEEN STGR'S 18L AND 21L, REF BOMBARDIER DWG SH670-31810 REV Y AND CRJ700 SRM'S 51-42-06-001-001 A01 AND SDR IPXA2021012864992Frame · damagedINSPECTION TYPE: C3 DEVIATION WAS FOUND DURING PERFORM 747-400F SRM 53-20-07 REPAIR 2 ON FUSELAGE FRAME (P/N: 65B01734-25) AT STA 820, S-9L.REPAIR IAW 747-400F SRM 53-20-07 REPAIR 2 REV 90.00 AND UPS EO B747-5320-79143-A.SDR R61A2021011700066Frame · crackedFRAME 52 RT SIDE HAS CRACK. REPLACED, IAW SRM 51-41-01, 51-42-01 & 51-43-01.SDR DALA2021011100142Frame · crackedCRACK INDICATION ON FRAME 20 LT SIDE ON DOOR STOP 1, OPEN FASTENER HOL E 3 ON FRAME. CORRECTIVE ACTION: PERFORMED ROTOTEST INSPECTION ON COMMON AFFECTED HOLES AFTER SEPARATION OF LAYERS ON DOOR STOP 1 LOCATE FR 20 LT AND DID NOT FIND CRACKS. OK FOR SERVICE.SDR CALA2021011100027Frame · corrodedBULK CARGO COMP'T AT FRAME 60 BETWEEN STRINGER 44L-43L SHEAR TIE HAS CORROSION A3NB-05-3-6026, PER HAECO LCQ NON ROUTINE CARD 929 2694. REMOVED AND REPLACED SHEAR TIE IN AFT CARGO PIT AT FRAME 60 BETWEEN STRINGER 44L-43L, IAW A320 SRM 51-72-11.SDR CALA2021011100025Frame · corrodedBULK CARGO COMP'T FRAME 63 BETWEEN STRINGER 41L-42L, SHEAR TIE HAS CORROSION A3NB-05-3-6026, PER HAECO LCQ NON ROUTINE 9292696 GENERATED BY V899828. REMOVED AND REPLACED SHEAR TIE AT FRAME 63 BETWEEN STRINGER 41L- 42L, IAW A320 SRM 51-72-11.SDR SWAA2021012644266Frame · dentedDENT ON FRAME AT FWD CARGO BAY BS 420 S-25L WL 158. REPAIRED DENT ON FRAME FCB BS 420 S-25L WL 158, IAW 737-700 SRM 53-30-07-2R-1 REPAIR 1.SDR SWIA202155376Rib · wrinkledHORIZONTAL RT SIDE RIB 14 IS WRINKLED AND CRACKED 4TH AFT LIGHTNING HOLE. PARTS ON ORDER 170-62620-002 MR 1637441. REMOEVED AND REPLACED RIB 14, IAW ETD 2021-000616 REV: DATED: 1-12-2021.SDR SWAA2021011140826Flange · corrodedCORROSION, ON FRAME UPPER FLANGE BS 727D, STR 25L, WL 154.SDR CALA2021010700020Frame Splice · crackedLT CABIN FLOOR OUTBOARD FRAME 68 SPLICER HAS A CRACK ON UPPER FLANGE SUPPORT TASK. REMOVED AND REPLACED LT CABIN FLOOR OUTBOARD FR 68 SPLICE, IAW A319 SRM 51-42-11 PG 21, 22, 25 AND 26 CAT "A".SDR SWAA2021020239731Frame · crackedCRACK IN RADIUS OF FRAME AT B.S. 312 JUST ABOVE FORWARD ENTRY DOOR CUT OUT. / REPAIRED FRAME BS312 JUST ABOVE FWD ENTRY DOOR CUTOUT PER SWA EA 21-153-00078 REV IR (ATS ER 21-01024 REV IR)SDR DALA2021010600067Frame · crackedCRACK ON FRAME 43 OPEN HOLE RT SIDE FOOT COUPLING IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FRAME, PER DELTA WC 5311- 01239-02B-DE. OK FOR SERVICE.SDR VNAA2021010499912Frame · crackedFRAME AT FS 333.00 BETWEEN STRINGER 1RT AND STRINGER 2RT IS CRACKED.SDR VNAA202101049999Frame · corrodedFRAME AT FS 310.00 FROM STRINGER 25R TO PRODUCTION SPLICE AT 18R REQUIRES REMOVAL AND INSTALLATION TO FACILITATE OTHER MAINTENANCE, REPAIR OF STRINGERS 20R AND 21R.SDR VNAA202101049997Frame · corrodedSTGR 25R FROM FS 280.00 TO FS 333.00 REQS REPLACEMENT DUE TO MULTIPLE AREAS OF OUT OF LIMITS CORROSION.SDR VNAA202101049996Frame · corrodedSTGR 26R FROM FS 280.00 TO FS 333.00 REQS REPLACEMENT DUE TO MULTIPLE AREAS OF OUT OF LIMITS CORROSION.SDR VNAA202101049995Frame · corrodedFRAME AT FS 310.00 IS CORRODED BETWEEN STR 25 LT AND STR 25 RT, FWD SIDE OF FRAME.SDR VNAA202101049994Frame · corrodedFRAME AT FS 319.70 IS CORRODED BETWEEN STR 26 LT AND STR 26 RT, FWD SIDE OF FRAME. REPLACED FRAME.SDR SWIA202155711Frame · corrodedFRAME AT 364.00 BETWEEN STGR21L - 22L IS CORRODED ON THE FORWARD FACE. (C-CHECK) RO 1/29/2021 CORROSION ON FRAME AT FS364.00 BETWEEN STGR21L-22L EVALUATED AS OUT-OF-LIMITS. REMOVED DAMAGED FRAME SECTION, AND INSTALLED NEW FRAME SECTION. COMPLIED WITH ALL SDR DALA2021010400020Frame · crackedCRACK ON FRAME 68 LT DOOR STOP 1 LOWER INBOARD HOLE. CORRECTIVE ACTION: PERFORMED REPAIR, PER 53-41-12-205-010. MONITOR INSPECTION AT 3200 FC INTERVALS.SDR SWIA202155710Frame · corrodedFRAME AT FS364.00 BETWEEN STGR22R - 23R IS CORRODED ON THE FORWARD FACE. (C-CHECK) RO 1/29/2021 REMOVED CORROSION ON FRAME AT FS364.00 BETWEEN STGR22R -23R, AND EVALUATED AS OUT-OF-LIMITS. REMOVED CORRODED FRAME SECTION, AND INSTALLED NEW FRAME SECTION. CSDR FDEA202012310308Frame · crackedCRACK INDICATION ON FRAME 40 TO CENTER WING JOINT AT UPPER SKIN LEVEL TENSION BOLT JUNCTION AREA OPEN FASTENER HOLES LOWER POSITION RH SIDE, CRACK DIRECTION IS 6 O CLOCK IN FWD CARGO COMPARTMENT (1EA) PERFORMED REAPIR ON FRAME 40 TO CENTER WING JOINT AT UPSDR FDEA202012310182Frame · crackedCRACK INDICATION ON FRAME 13 OPEN FASTENER HOLE AT LEVEL OF STR 9 RT SIDE, CRACK DIRECTION IS 9 O`CLOCK AT FWD GALLEY AREA (1 EA). REPLACED STRINGER SECTION LOCATED ON FR 13 AT LEVEL STR 9 RT SIDE, IAW A300-600 SRM 51-40-20-001 AND DRAWING #A53610301 ISSUE K SDR SWIA202055656Nut Plate · elongatedLT FLOOR SILL 1.5" AFT OF FS 559.00 HAS 1 EA ELONGATED NUTPLATE HOLE. C-CHECK RO 1/28/2021. REMOVED AND REPLACED LT FLOOR SILL AFT OF FS 559, IAW CRJ 200 SRM-51-42-06 AND 51-42-21 REV 38, DATED 7/10/19. FORM 337 AND MAJOR REPAIR TASK CARD 51-900-1003-SKY COSDR FDEA202012300181Frame · crackedCRACK INDICATION ON FRAME 13 OPEN FASTENER HOLE AT LEVEL OF STR 9 LT SIDE, CRACK DIRECTION IS 3 O`CLOCK AT FWD GALLEY AREA (1 EA). REPLACED STRINGER SECTION LOCATED ON FR 13 AT LEVEL STR 9 LT SIDE, IAW A300-600 SRM 51-40-20-001 AND DWG #A53610301 ISSUE K SHEESDR FDEA202012280444Frame · crackedCRACK INDICATION ON FRAME 54 (2 INCH AFT SIDE) AND STGR 44LT (1 INCH UPPER) OPEN HOLE IN AFT CARGO COMPARTMENT (1 EA) (CRACK DIRECTION 12 O CLOCK) PERFORMED REPAIR LOC ON FRAME 54 (2 INCH AFT SIDE) AND STGR 44LT (1 INCH UPPER) OPEN HOLE IN AFT CARGO COMPARTMENSDR FDEA202012280443Frame · crackedCRACK INDICATION ON FRAME 54 STGR 36 LH (1 INCH UPPER) OPEN HOLE IN AFT CARGO COMPARTMENT (1 EA)(CRACK DIRECTION 12 O CLOCK) PERFORMED REPAIR LOC ON FRAME 54, STGR 36LH (1 INCH UPPER) OPEN HOLE IN AFT CARGO COMPARTMENT IAW EA 6-5316-T0359314. TITLE: FUSELASDR DALA2020122804282Frame · crackedCRACK INDICATION ON FRAME 35 LOCATED AT LEVEL STR 30 L HOLE NR 6 IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: PERFORMED TIME LIMIT REPAIR ON FRAME 35 LOCATED AT LEVEL STR 30L HOLE NR 6 IN FWD CARGO COMP, AS PER PRI REV 0, REV 1, REV 2, ER/A 588711- 14ASDR DALA2020122804280Frame · crackedCRACK INDICATION ON FRAME 36 HOLE NR 4 LOCATED 5 INCH OUT SIDE Y1292 LT IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: PERFORMED REPAIR ON FR 36 HOLE NR 4 LOCATED SICH OUTSIDE Y1292 LT IN FWD CARGO COMPARMENT, AS PER PRI REV 0, REV 1, REV 2, ER/A 588715-SDR DALA2020122804279Frame · crackedCRACK INDICATION ON FRAME 36 ON HOLE NR 7 LOCATED 2 IN OUT SIDE OF Y1292 LT IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: PERFORMED REPAIR ON FR 36 HOLE NR 7 LOCATED 2 IN OUTSIDE OF Y1292 LT IN FWD CARGO COMPARTMENT, AS PER PRI REV 0, REV 1, REV 2 ER/A SDR DALA2020122804278Frame · crackedCRACK INDICATION ON FRAME 36 HOLE NR 6 LOCATED 3 INCH OUT SIDE Y1292 LT IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: PERFORMED REPAIR ON FR 36 HOLE NR 6 LOC 3 IN OUT SIDE Y1292 LT IN FWD CARGO COMPARTMENT, AS PER PRI REV 0, REV 1, REV 2 ER/A 588715- 14SDR DALA2020122804277Frame · damagedOUT LIMIT FRAME 35 HOLE NR 10 STR 30L HAVING A DIMAETER THATS LARGE THAN MINIMUM SRARING DIAMETER OF 2ND OVERSIZE IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: PERFORMED TIME LIMIT REPAIR ON FRAME 35 HOLE NO 10 STR 30L IN FWD CARGO COMP, AS PER PRI REV 0, REV SDR REXA2021011200867Frame · corrodedFWD AVIONICS BAY FS 310 FRAME CORRODED BETWEEN STRINGER 26L & 26R. REPAIRED FS 310 FRAME CORROSION BETWEEN STRINGER 26L & 26R, IAW CRJ 900 SRM 53-00-06-201-004-A01 & 51-21-06-001-001-A01.SDR DALA2024022902867Frame · crackedSHIP 671 FUSELAGE / FRAME / RHS - BS1640 - STR-14R / LOWER HOLES / CRACK. CORRECTIVE ACTION: REF ERA 588944-14. (1685878)SDR DALA2021010800133Frame · crackedCRACK WAS FOUND AT HOLE NR 6 ON LT AT FR 35, BETWEEN STR 28 AND STR 31. CORRECTIVE ACTION: MONITOR CRACK, PER AA REFERENCE 32-588711.SDR SWIA202056028Frame · corroded*FRAME, FS517.00, LOWER FLANGE AND WEB ARE CORRODED BETWEEN STGR26L & STGR27. (MARKED) (C-CHECK) RO 2/6/2021 REMOVED CORROSION AT FS517.00 LOWER FLANGE AND WEB BETWEEN STGR26L AND STGR27. REF CRJ700 SRM 51-21-06-001-001-A01. NDT DEFECT FREE. EVAL MATERISDR REXA2021011200864Frame · corrodedFS 1088.20 FRAME IS HEAVILY CORRODED ON THE AFT FACE BETWEEN STR 25L TO STR 25R. REPAIRED FS 1088.20 FRAME, IAW CRJ 900 SRM 53-00-06-201-001-A03.SDR DALA2020122304230Frame · crackedCRACK FOUND AT FRAME 40 RT VERTICAL WEB ABOVE CENTER WING BOX LOWER PANEL AT HOLE H260. CORRECTIVE ACTION: PERFORMED REPAIR PER ER/A 588846-14AD REV ORIGINAL.SDR SWIA202056023Frame · corroded*CIRCUMFERENTIAL JOINT AT FS333.00 HAS CORROSION STGR25R €“ STGR23R. (MARKED) (C-CHECK) RO 2/6/2021 REMOVE CORROSION ON CIRCUMFERENTIAL JOINT AT FS333.00 STGR25R-STGR23R. WITHIN LIMITS REF REO 670-53-21-1918 REV -- DATED 2020-12-31. COMPLIED WITH 51-900-SDR SWIA202056022Frame · corroded*FRAME, FS349.00, HAS CORROSION ON THE FORWARD FACE BETWEEN STGR27 & STGR26R. (MARKED) (C-CHECK) RO 2/6/2021 BLENDED ON FRAME AT FS 349 BETWEEN STR 27 TO 26R PER CRJ 700 SRM 51-21-06-001-001-A01 AND RESTORED FINISH AREA PER REO 670-53-21-1917 REV -- DATED SDR SWIA202056018Frame · corroded*FRAME, FS319.00 FORWARD WEB IS CORRODED BETWEEN STGR26L & STGR25R. (C-CHECK) RO 2/6/2021 REPAIRED FRAME FORWARD WEB AT FS 319.00 BETWEEN STR. 26L AND 25R AS PER CRJ 700 SRM 53-00-06-201-006-A01. SKYWEST TASK CARD 51-900-1002-SKY COMPLIED WITH.SDR SWIA202056017Frame · corroded*FRAME, FS333.00 LOWER FLANGE IS CORRODED BETWEEN STGR26L & STGR25R. (C-CHECK) RO 2/6/2021 REPAIRED CORROSION ON LOWER FRAME FLANGE AT FS 333.00 BETWEEN STRINGER 26L AND 25R AS PER CRJ 700 SRM 51-42-21-001-001-A01. SKYWEST TASK CARD 51-900-1002-SKY COMPLIESDR SWIA202055860Frame · corrodedCORROSION ON FRAME FS333.00, SKIN ATTACH FLANGE; BETWEEN STGR-20L - STGR-18L (C-CHECK) RO 2/1/2021 REPLACED FRAME SECTOR, FS333.00, STRINGER 18L-21L PER SRM 51-42-06-001-001-A01, SRM 51-42-21-001-001-A01 & DRAWING SH670-31810 REV Y. CHECKS GOOD. SEE CONSDR SWIA202055662Bracket · crackedFS 621 TO FS 625 OBLIQUE ANGLE AT STR 14R IS CRACKED. C-CHECK RO 1/28/2021. REMOVED AND REPLACED ANGLE AT FS 621 TO FS 625, IAW CRJ200 SRM 51-42-20. REFER TO CONTINUATION CARD FOR WORK PERFORMED.
Back to JASC 5311