What was found
OUT LIMIT FRAME 35 HOLE NR 10 STR 30L HAVING A DIMAETER THATS LARGE THAN MINIMUM SRARING DIAMETER OF 2ND OVERSIZE IN FWD CARGO COMPARTMENT. CORRECTIVE ACTION: PERFORMED TIME LIMIT REPAIR ON FRAME 35 HOLE NO 10 STR 30L IN FWD CARGO COMP, AS PER PRI REV 0, REV 1, REV 2 ER/A 588711-14AD AND ER/A NO588711-14AD.