JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020091003025Frame · corrodedDURING INITIAL INSPECTION CORROSION LEVEL 2 FRAME CLIP STA 1560 BETWEEN STR 26-27 RT WAS REPLACED.SDR ABXR2020090900080Frame · corrodedSTRINGER CLIP AND FRAME WEB CORROSION.SDR SWAA2020101215061Frame · crackedCRACK FRAME ON BS 294.5 STUB FRAME BETWEEN S-8R TO S9R FWD GALLEY AND LAV. REPLACED STUB FRAME BS 294.5 BETWEEN S-8R TO S-9R FWD GALLEY AND LAV, IAW B737-700 SRM 51-40-02 AND DRAWING 141A8370.SDR SIMA202009086007Frame · crackedFR 72 CRACKED STGR 16L AT RIVET BUCKTAIL. C/A PERFORMED REPAIR TO FR72 LT SECTION, IAW ERS-EM-5300-4180 AND EMB 145 SRM 53-00-04, ITEM 3, FIG.201.SDR SWIA202053673Frame · corrodedCORROSION ON FRAME FS 549.00 BETWEEN STGR 27 AT STGR 26L FWD SIDE. C-CHECK RO 10/22/2020. COMPLIED WITH MHI RJ REO-ALL STEPS ACCOMPLISHED.SDR SWIA202053625Frame · corrodedCORROSION ON FRAME FS 310.00 BETWEEN STGR 26R-STGR 24L, AREAS MARKED ON FRONT AND AFT SIDES. C-CHECK RO 10/22/2020. REMOVED CORROSION ON FRAME FS 310.00 BETWEEN STGR 26R-STGR 24L, REF CRJ 700 SRM. EVALUATED AND FOUND TO BE OUT OF LIMITS. REMOVED CORRODED LSDR SWIA202053624Frame · corrodedCORROSION ON FRAME FS 295.00 BETWEEN STGR 26R-20L ON MULTIPLE AREAS, FRONT AND AFT SIDES, AREAS MARKED. C-CHECK RO 10/22/2020. REMOVED AND INSTALLED NEW FRAME SECTION REINFORCING ANGLE FROM STR 20L TO STR 25R, REF REO DWG, CRJ 700 SRM. NO LEAKS NOTED.SDR R61A2020092600646Frame · corrodedWHILE A/C WAS OUT OF SERVICE FOR HEAVY CHECK FR 88 LOWER FLANGE IS CORRODED BETWEEM STGR 27R & 28R. REPAIRED FRAME SECTION, IAW ETD 2020-170-027145-B. A/C REMAINS OUT OF SERVICE FOR HEAVY CHECK COMPLETION. MAJOR REPAIR.SDR DALA2020090953008Frame · crackedSHIP 3165, CRACK INDICATION ON FRAME 20 RT SIDE ON OPEN FASTENER HOLE 1 INTERCOSTAL FITTING LAYER AT DOOR STOP 7, CRACK DIRECTION IS 4 O`CLOCK. CORRECTIVE ACTION: REPLACED INTERCOSTAL FITTING ON FRAME 20 RT SIDE AT LEVEL OF DOOR STOP NR 7, AS PER ER/A N. 5875SDR SWIA202053614Frame · corrodedCORROSION ON AFT FACE OF FRAME AT FS 879.00, BETWEEN STGR 26L-25R. C-CHECK RO 10/22/2020. REMOVED AND REPLACED FRAME SECTOR AT FS 879.00 BETWEEN STR 26L-25R, REF CRJ 700 SRM AND REO. NO LEAKS NOTED.SDR SWAA2020090914120Frame · crackedCRACK IN BS 325.38 FRAME WEB AT STR 23L. FABRICATED BS 325.28 FRAME WEB TRIM 707 ST 6 NR 0.040' CLAD LOT NR 1425360-1 TREATED IAW DWG NR 141A1361. OK TO PRIME 88340C 03SEP20 INSP 316 RII 03SEP20. PRIMED BS 325.28 FRAME WEB, IAW DWG NR 141A1361. OK TO INSTASDR SWIA202053610Strap · corrodedFS 319 FRAME STRAP AT FLOOR LEVEL WL 72.50 FWD OF SERVICE DOOR HAS EVIDENCE OF CORROSION. C-CHECK RO 10/22/2020. BLENDED CORROSION, IAW CRJ700 SRM. ORIGINAL THICKNESS OF UPPER OUTER STRAP 0.100, MATERIAL REMOVED 0.030, REMAINING MATERIAL 0.070. ORIGINAL THSDR SWIA202053093Frame · corrodedCORROSION ON FWD AND AFT SIDE OF FRAME BETWEEN STGR 25L-26R AT FS 319.00. C-CHECK RO 10/4/2020. REMOVED AND REPLACED FS 319 LOWER FRAME SECTOR, REF DWG AND CRJ200 SRM. SEE CONTINUE CARD FOR DETAILS. COMPLIED WITH TASK.SDR DALA2020090933005Frame · crackedSHIP 3165, CRACK INDICATION ON FRAME 16 LT SIDE ON OPEN FASTENER HOLE 3 FRAME AND INTERCOSTAL FITTING LAYERS AT DOOR STOP 7. CRACK DIRECTION IS 1 O`CLOCK. CORRECTIVE ACTION: REPLACED ON FRAME 16 LT SIDE INTERCOSTAL FITTING AT DOOR STOP 7, AS PER PRI 587446-1SDR DALA2020090933004Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE ON OPEN FASTENER HOLES 1 AND 3 INTERCOSTAL FITTING LAYER AT DOOR STOP 7. CRACK DIRECTIONS ARE FOR HOLE 1:6 AND 8 O`CLOCK, FOR HOLE 3:9 AND 10 O`CLOCK. CORRECTIVE ACTION: REPLACED ON FRAME 16 RT SIDE INTERCOSTAL FITTING ATSDR DALA2020090923003Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE HOLE 6 AT DOUBLE JOGGLE AREA AT LEVEL DOOR STOP 7 ON UPPER FUSELAGE (1EA), CRACK AT 1 O'CLOCK. CORRECTIVE ACTION: REPAIRED FR 16 RT SIDE HOLE 6 AT DOUBLE JOGGLE AREA AT LEVEL DOOR STOP 7 ON UPPER FUSELAGE, AS PER PRI 58740SDR DALA2020090923002Frame · crackedCRACK INDICATION ON FRAME 20 AT FASTENER HOLE 6 AT LEVEL OF DOOR STOP 7 RT SIDE. CRACK DIRECTION 10 O`CLOCK VIEW LOOKING INBOARD AND DEPTH IS 0.071 INCH. CORRECTIVE ACTION: PERFORMED REPAIR ON FRAME 20 RT ON FASTENER HOLE NR 6 AT LEVEL OF DOOR STOP NR 7 DOUBSDR VNAA2020090299912Frame · corrodedFS 1051 FRAME IS CORRODED BETWEEN STRINGER 25L AND STRINGER 25R. REPAIRED IAW STS EA 79-2020-009 REV P2 DATED 8/19/2020.SDR VNAA202009029999Frame · corrodedFRAME AT FS 349.00 HAS CORROSION ON THE FLANGE AT STRINGER 26R. REMOVED AND REPLACED FRAME P/N SH670-31357-5 IAW CRJ 700 SRM 51-42-06-001-001-A01.SDR 2A6R2020090257301Frame · corrodedHEAVY CORROSION FOUND ON BOTTOM CABIN FLOOR FRAME DURING 12 YEAR INSPECTION ON BOTH ENDS OF THE LOWER PART OF THE FRAME THAT HELPS MOUNT THE LOWER FIXED BELLY PANEL.SDR SWIA202053083Frame · corrodedFS 605-STGR 25L/25R FRAME CORRODED. C-CHECK RO 10/4/2020. REMOVED CORROSION AT FS 605 STGR 25L TO 25R, REF CRJ200 SRM. FOUND TO BE OUT OF LIMITS. PERFORMED FRAME REPAIR AT FS 605 BETWEEN STGR 26R TO 27R, REF CRJ200 SRM AND DWG. COMPLIED WITH TASK CARD.SDR SWIA202053082Frame · corrodedFS 589-STGR 24L/26R-FRAME CORRODED. C-CHECK RO 10/4/2020. REPAIRED FS 589-STGR 24L/26R-FRAME CORROSION, REF CRJ200 SRM. LEAK CHECK GOOD.SDR SWAA2020100212433Frame · crackedSUSPECT FRAME CRACKED ON AFT SIDE AT RIVET HOLE BS 400 STR 8R. CUT-OUT DAMAGED AREA. PERFORMED HFEC INSPECTION. PERFORMED DVI AROUND DAMAGED AREA. FABRICATED FILLER, LAY OUT AND DRILLER, TRIME AND DRILLED NEW RAPAIR PART (P/N 1530809 AND P/N 1530812). TRESDR SWAA2020092915611Frame · puncturedFRAME AT STA 500C PUNCTURED BETWEEN S-11L AND S-13L. REPAIRED PUNCTURE AT FRAME AT STA 500C BETWEEN S-11L AND S-13L, AS PER B737-700 SRM 53-00-07-2R-1.SDR SWAA2021081512364Frame Splice · corroded***CORROSION*** ON FRAME AT AFT CARGO BAY BS787 RBL24 WL157. / REMOVED EXISTING FRAME SPLICE AND REPLACED NEW FABRICATED FRAME SPLICE AT ACB B/S 787; RBL 24 - RBL 31 IAW SRM 51-40-02-0G-0; DWG # 146A1262. 92892U 03SEP20.SDR SWAA2020092115999Frame · dentedDENT ON FRAME AT AFT CARGO BAY BS 727B S-22R WL 169. DENT ON FRAME AT BS 727B STR 22R WL 169 FOUND TO BE OUT OF LIMITS, PER SRM 53-00-07-1A-1. ACCOMPLISHED FRAME REPAIR BS 727B STR 22R, IAW ER 20-03199 REV IR AND EA 20-153-01727 REV IR.SDR SWAA2020092115998Frame · dentedDENT ON FRAME AT AFT CARGO BAY BS 727E 2' BELOW S-22L WL 168. REMOVED DAMAGE ON FRAME AFT CARGO BAY BS 727E 2' BELOW STR 22 LT W/L 168 AND REPAIRED, PER ATS ER 20-03200 REV IR AND SWA EA 20-153-01704 REV IR.SDR Y2PA2020090220020Former · crackedDISCREPANCY: DURING C-CHECK AT KDHN FOUND FORWARD SIDE OF FRAME FORMER CRACKED AT FUSELAGE STATION FS 1086 AT LONGERON 28R. CORRECTIVE ACTION: COMMERCIAL JET STOP DRILLED CRACK AND VERIFIED CRACK CONTAINMENT VIA NDT. FABRICATED, DRILLED, DEBURRED, TREATED, PSDR VNAA202008279992Frame · corrodedFS 333.00 IS CORRODED BETWEEN STRINGER 24R AND 25R.SDR VNAA202008279991Frame · corrodedFS 310.00 IS CORRODED BETWEEN STRINGER 24R AND 27R.SDR 2A6D2020082702603Frame · chafedCHAFING ON THE LT X-FRAMES AFT UPPER AND LOWER LEGS. THE AFT UPPER LEG DAMAGE IS .24” BY .22” AND IS .024” AT ITS DEEPEST POINT LOCATED AT STA 3650, WL 1979, AND BL 430L. THE AFT LOWER LEG DAMAGE IS .74” BY .19” AND MEASURES .002” LOCATED AT STA 3650, WL 2305,SDR SWIA202052870Frame · corrodedFS 280.00 STRG 22RH-23RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP CORRODED, MARKED. C-CHECK RO 9/27/2020. REPAIRED CORROSION FROM FS 280.00 STRG 22RH-23RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP. FOUND TO BE WITHIN LIMITS, REF CRJ-700 SRM AND BOMBARDIER DWG.SDR SWIA202052869Frame · corrodedFS 280.00 STRG 21RH-22RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP CORRODED, MARKED. C-CHECK RO 9/27/2020. REMOVED CORROSION FROM FS 280.00 STRG 21RH-22RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP, REF CRJ-700 SRM. FOUND TO BE WITHIN LIMITS, REF CRJ-700 SRM ANDSDR SWIA202052868Frame · corrodedFS 280.00 STRG 20RH-21RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP CORRODED, MARKED. C-CHECK RO 9/27/2020. REMOVED CORROSION FROM FS 280.00 STRG 20RH-21RH BELOW FLOOR CIRCUMFERENTIAL JOINT STRAP, REF CRJ-700 SRM. FOUND TO BE WITHIN LIMITS, REF CRJ-700 SRM ANDSDR SWAA2020092116294Frame · dentedDENT ON FRAME AT FWD CARGO BAY BS 500 BS 24R WL 162. REMOVED DAMAGE ON FRAME. FWD CARGO BAY BS 500B STR 24 RT W/L 162 REPAIRED, IAW ATS ER NR 20-03226 REV IR AND SWA EA 20-153-01738 REV IR.SDR FY4Y202009108002Frame · corrodedCORROSION WAS FOUND AT AFT CARGO FWD BULKHEAD LOWER CHORD AT BS 727 BETWEEN S-25L AND 25R.SDR SIMA2020091086008Frame · crackedFR 73 CRACKED STGR 16R-17R. C/A REMOVED AND INSTALLED FR 73 SECTION, IAW EMB 145 SRM 51-40-02.SDR FDEA202008262029Frame · dentedCABIN - MAIN DECK UPON REMOVAL OF UPPER SIDEWALL LINER FOR INSPECTION ACCESS ( WORK CARD T1-5310-71733 A P2I ) FOUND FRAME DENTED AT STATION 1601 , LONGERON 12 LEFT . CABIN - MAIN DECK CARGO COMPARTMENT , DENTED FRAME AT STATION 1601 , LONGERON 12 LEFT SDR SWIA202052861Frame · corrodedCORROSION ON FRAME FS 645.00 BETWEEN STGR 26L-STGR26R, MARKED. C-CHECK RO 9/27/2020. REMOVED CORROSION ON FRAME FS 645.00 BETWEEN STGR 26L-STGR26R, REF CRJ-700 SRM AND COMPLIED WITH MHIRJ REO. THE FRAME WITHIN LIMITS.SDR SWIA202052860Frame · corrodedFS 1015.00 FRAME FWD SIDE HAS CORROSION BETWEEN STGR 26L TO 26R. C-CHECK RO 9/27/2020. REMOVED CORROSION ON FS 1015.00 FRAME FWD SIDE BETWEEN STGR 26L TO 26R, REF CRJ700 SRM. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW FRAME SECTION AT FS 1015.00,SDR SWIA202052859Frame · corrodedFS 1031.00 FRAME FWD SIDE HAS CORROSION BETWEEN STGR 25L TO 25R. C-CHECK RO 9/27/2020. REPAIRED CORROSION ON FS 1031.00 FRAME FWD SIDE ON LOWER FLANGE AT STGR 25L TO 25R, REF CRJ 700 SRM AND COMPLIED WITH REO. SEE CONTINUATION CARD FOR DETAILS.SDR SWIA202052858Frame · corrodedFS 1051.30 FRAME AFT SIDE HAS SUSPECTED CORROSION BETWEEN STGR 25L AND 25R. C-CHECK RO 9/27/2020. NO CORROSION FOUND AT FS 1051.30 FROM STGR 25L-26L OR STGR 25R-26R. REMOVED CORROSION ON FRAME FLANGE BETWEEN 26R AND 26L AT FS 1051.30, REF CRJ700 SRM. WITHISDR SWIA202052857Frame · corrodedFS 1047.00 FRAME FWD SIDE HAS CORROSION BETWEEN STGR 25L AND 26L. C-CHECK RO 9/27/2020. REMOVED CORROSION AT FS 1047.00 FRAME FWD SIDE HAS CORROSION BETWEEN STGR 25L AND 26L, REF CRJ-700 SRM, WITHIN LIMITS.SDR SWIA202052856Frame · corrodedFS 310.00 FRAME HAS CORROSION ON THE FORWARD SIDE STGR 24L-STGR 24R, MARKED. C-CHECK RO 9/27/2020. REMOVED CORROSION FROM FS 310.00 FRAME ON THE FWD SIDE STGR 24L TO STGR 24R, REF CRJ700 SRM. RECEIVED REO, WITHIN LIMITS. COMPLIED WITH ALL STEPS OF REO.SDR SWIA202052855Frame · corrodedFS 295.00 FRAME HAS CORROSION ON THE AFT SIDE STGR 25L STGR 24R, MARKED. C-CHECK RO 9/27/2020. REPAIRED FS 295.00 FRAME HAS CORROSION ON THE AFT SIDE STGR 25L-STGR 24R, REF CRJ-700 SRM. SEE CONTINUE CARD FOR MORE DETAILS.SDR SWIA202052854Frame · corrodedCORROSION ON CIRCUMFERENTIAL JOINT INTERFACE FS 280.00-FS 280.62 STGR 23L-STGR 24R. C-CHECK RO 9/27/2020. REMOVED CORROSION ON CIRCUMFERENTIAL JOINT INTERFACE FS 280.00-FS 280.62 STGR 26L-STGR 24R, REF CRJ700 SRM. OUT OF LIMITS. RECEIVED REO. COMPLIED WITSDR SWIA202052845Frame · corrodedFWD CARGO BAY FRAME CORRODED, AS MARKED, FS 517 BETWEEN STGRS 26L/26R. C-CHECK RO 9/27/2020. REPAIRED FWD CARGO BAY FRAME CORRODED, AS MARKED, FS 517 BETWEEN STGRS 26L/26R, REF CRJ-700 SRM. SEE CONTINUE CARD FOR MORE DETAILS. LEAK CHECK GOOD.SDR SWIA202052841Frame · corrodedFS 1000.00 STRG 26L-25L FWD SIDE OF FRAME CORRODED, MARKED. C-CHECK RO 9/27/2020. REMOVED CORROSION AT FS 1000.00 STGR 26L-25L FWD SIDE OF THE FRAME FLANGED, REF CRJ700 SRM. OUT OF LIMITS. RECEIVED REO. COMPLIED WITH ALL STEPS OF REO. NO LEAKS NOTED. CSDR SWIA2020090252175Frame · corrodedF.S. 333 FRAME IS CORRODED FROM 23L-17L. C-CHECK RO 8/29/2020. REMOVED AND INSTALLED NEW FRAME SECTORS AT FS333.00 STRINGER 18R TO 23R IAW CRJ-200 SRM, BOMBARDIER DRAWING, AND SKYWEST CARD. COMPLETED M-337 AND M-131. WEIGHT AND BALANCE NOT AFFECTED PART FOSDR SWIA2020090252174Frame · corrodedF.S. 333 FRAME IS CORRODED FROM STRINGER 18R TO 17R. C-CHECK RO 8/29/2020. REMOVED AND INSTALLED NEW FRAME SECTORS AT FS333.00 STRINGER 18R TO 23R IAW CRJ-200 SRM, DRAWING AND SKYWEST CARD. COMPLETED FORM M-337. WEIGHT AND BALANCE NOT AFFECTED.
Back to JASC 5311