JASC 5311
Service difficulty reports · 61,540
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20201008138Frame · crackedFRAME STA 480 IS CRACKED AT ATTACH FITTING FASTENER HOLE AT STR 8R. REPAIRED FRAME BS 480 RT STRINGER 8, PER ATS ER 20-03227 REV IR AND SUN COUNTRY T/C ENG-53SCA-10615 REV 00.SDR SCNA20201008137Frame · crackedFRAME STA 440 IS CRACKED AT ATTACH FITTING FASTENER HOLE AT STR 8R. REPAIRED FRAME BS 440 STR 8 RT, PER ATS ER 20-03227 REV IR AND SCA ENG-53SCA-10615 REV 00.SDR SCNA20201008136Frame · crackedFRAME STA 500D IS CRACKED AT ATTACH FITTING FASTENER HOLE AT STR 8L. REPAIRED FRAME BS 500D STRINGER 8 LT, PER ATS ER 20-03227 REV IR AND SUN COUNTRY T/C 53SCA-10615 REV 00.SDR SCNA20201008135Frame · crackedFRAME STA 440 IS CRACKED AT ATTACH FITTING FASTENER HOLE AT STR 8L. REPAIRED FRAME STA 440 STRINGER 8 LT, PER ATS ER 20-03227 REV IR AND SUN COUNTRY T/C ENG-53SCA-10615 REV 00.SDR SCNA20201008134Frame · crackedFRAME STA 400 IS CRACKED AT ATTACH FITTING FASTENER HOLE AT STR 8L. REPAIRED FRAME BS 400 STRINGER 8 LT, PER ATS ER 20-03227 REV IR AND SUN COUNTRY T/C ENG-53SCA-10615 REV 00.SDR SWIA202053440Frame · corrodedTHERE IS EVIDENCE OF CORROSION AT FS 319.70 FRAME BETWEEN STR 18L AND STR 21L. C-CHECK RO 10/17/2020. REMOVED AND REPLACED THE CORRODED FRAME AT FS 319.70 BETWEEN STGR 18L AND STGR 21L WITH NEW FRAME (P/N SH670-31891-3S), PER BOMBARDIER DWG AND CRJ700 SRM. SDR SWIA202052904Frame · corrodedFOUND EVIDENCE OF CORROSION ON FRAME SECTOR AT FS 319.00. DETERMINED TO BE A "MAJOR REPAIR" FORM M-337 REQUIRED. FILED CLOSED (10/3/2020). NEW FRAME SECTOR INSTALLED AT FS 319.00, IN REFERENCE TO CRJ SRM AND SOLID RIVETS INSTALLED ALSO HI LOC'S INSTALLED ANSDR IPXA2020092660641Frame · dentedINSPECTION TYPE: SEG DENT FOUND ON RT LOWER RIB AT STA 680 BETWEEN S-23R AND S-25R. REPAIRED IAW SRM 53-00-07-2R-5 DETAIL III, PER SRM 53-00-07-2R, IAW BOEING MESSAGE REF MOE-UPS-20-0045-02B.SDR SIMA20200926005Frame · crackedFRAME 73 IS CRACKED BETWEEN STRINGERS 16R-17R. C/A: REMOVED AND REPLACED LOWER SECTION OF FRAME 73, IAW EMB 145 SRM 51-40-02.SDR SIMA20200926002Frame · crackedFR 72 IS CRACKED IN UPPER RADIUS BETWEEN STGR 16L-17L. C/A: REMOVED AND REPLACED LOWER SECTION OF FR 72, IAW EMB 145 SRM 51-40-02.SDR SWAA2020101422261Frame · dentedDENT ON FRAME AT AFT CARGO BAY BS767 3' BELOW S-22L WL 168. MARKED / REPAIRED B.S 767 FRAME 3' BELOW STR 22L IAW EA 20-153-01972 REV IR AND ATS ER 20-03355 REV IRSDR DALA2020092603175Frame · corrodedCORROSION LEVEL 2, DURING INITIAL INSPECTION, CORROSION WAS FOUND ON FRAME BETWEEN STR 29 RT / 27RT STA Y=1560 AT AFT CARGO COMPARTMENT. THE FRAME WAS REPAIRED, PER ERA 587768-14AD.SDR SWIA202053720Frame · corrodedCORROSION ON FS 310 FRAME BETWEEN STR 26L AND 27. C-CHECK RO 10/29/2020. INSTALLED NEW FRAME SECTION AT FS 310, PER CRJ200 SRM AND INSTALLATION DRAWING. INSTALLED NEW ANGLE SPLICE BRACKET, REF CRJ200 SRM AND INSTALLATION DRAWING. LEAK CHECKS ARE GOOD AT THSDR DALA2020092503163Frame · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION ON FRAME STA 1420 BETWEEN S-30 AND S-29R AFT CARGO COMPARTMENT. REPAIRED CORROSION, PER ERA 587774-14.SDR SWAA2020102222172Stub Frame · crackedCRACK FWD SERVICE DOOR CUT OUT ON STUD FRAME LOCATED BS 294.5 AT LEVEL STR 17R AT PASSENGER CABIN. REPLACED FWD SERVICE DOOR STUD FRAME LOCATED BS 294.5 AT LEVEL STRINGER 17R, IAW SRM B737-700 51-40-02 AND DRAWING 141A8350 REV A.SDR 2B5A202010130001Frame · corrodedFOUND CORROSION UNDER NUMBER ONE BATTERY GROUNDING LUG. THE FRAME THE LUG IS BOLTED TO REQUIRES REPAIR, PER PILATUS ENGINEERING PROVIDED REPAIR PROCEDURE.SDR DALA2020092303192Frame · crackedCRACK INDICATION ON FRAME 16 ON FASTENER HOLE NR 3 DOOR STOP 7 LT SIDE. CRACK DIRECTION 4 O`CLOCK AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED ROTOTEST INSPECTION ON AFFECTED HOLES NR 3 LOCATED DOOR STEP 01: AME 16 LT SIDE, AS PER NTM 51-10-01. CRACK INDSDR REXA2020092800663Frame · corrodedFRAME AT FS 589 CORRODED BETWEEN STGR 24R AND STGR 24L. REMOVED AND REPLACED FRAME SECTOR, IAW CRJ 200 SRM 51-42-06 AND 51-42-21. LEAK CHECK OF MIX MANIFOLD CHECK GOOD. NO DEFECTS NOTED AT THIS TIME, IAW CRJ 200 AMM 21-20-00-790-801.SDR SWIA202053870Frame · corrodedFS 409.00 IS CORRODED ON THE FORWARD SIDE ON THE FRAME DOUBLER BETWEEN STR 26 AND STR 27 AND ON THE AFT SIDE ON THE FRAME DOUBLER. C-CHECK RO 11/11/2020. REMOVED UNSERVICEABLE FS 409.00 FRAME DOUBLER BETWEEN STR 26 AND STR 27 AND AFT SIDE ANGLE ON THE FRAME SDR FDEA202009222289Frame · dentedCABIN, MAIN DECK CARGO COMPARTMENT FRAME FOUND DENTED AT STATION 1601, LONGERON 12 LEFT. CABIN, MAIN DECK CARGO COMPARTMENT AT STATION 1601, LONGERON 12 LEFT, DENTED LEFT HAND FRAME. REPAIRED, AS PER SRM 53-00-07-2R FIGURE 201 REPAIR 2. REPETITIVE INSPECTIOSDR FDEA202009222288Frame · dentedCABIN, MAIN DECK CARGO COMPARTMENT FRAME FOUND DENTED AT STATION 1721, LONGERON 12 RIGHT. CABIN, MAIN DECK CARGO COMPARTMENT DENTED FRAME AT STATION 1721 LONGERON 12. RIGHT REPAIRED, AS PER SRM 53-00-07-2R FIGURE 201 REPAIR 2. REPETITIVE INSPECTION REQUIREDSDR SWIA202053888Frame · corrodedFS 559.00+96 IS HEAVILY CORRODED ON THE FORWARD FLANGE AND AFT FACE AT STR 26R. C-CHECK RO 11/11/2020. REPAIRED FS 559.00+96 CORROSION ON THE FORWARD FLANGE AND AFT FACE AT STR 26R BY PERFORMING SPLICE REPAIR, IAW CRJ-200 SRM. COMPLETED SKYWEST TASK CARD ANSDR DALA2020092203146Frame · crackedCRACK INDICATION ON FRAME 16 AT DOUBLE JOGGLE AREA, RT SIDE, HOLE B, AT LEVEL DOOR STOP 7 AT FWD GALLEY AREA. CORRECTIVE ACTION: RT SIDE AT LEVEL DOOR STOP 7, AS PER PRI 587478-14AD REV 0 AND REV 1 ER/A NR 587478-14AD REV.SDR FDEA202009202268Frame · crackedSTA 1681 FRAME APPROX STR17R HAS CRACK INDICATION ALL WORK ACCOMPLISHED IAW FEDEX EA F-5310-T0356589 P1 FUSELAGE - EXISTING FLOOR BEAM REPAIR AT STA 1681, RBL44 TO RBL50 (EO F-5310-E0329555)SDR SWAA2021042717057Frame · dentedWHILE WORKING DENT CARD U213260; FOUND INTERNAL FRAME WEB TO BE BENT AT BS235.80; 17' ABOVE S-17R / REPAIRED INTERNAL FRAME WEB AT BS 235.80; 17' ABOVE S-17R PER EA 20-153-01906 REV. IR AND ER 20-03305 REV. IR. FACT AS A RESULT OF POST REPAIR INSPECTIONSDR SWIA202053640Frame · corrodedMAIN AVIONICS BAY FS 319.70 LOWER FRAME CORRODED BETWEEN STR 27 AND STR 26R. C-CHECK RO 10/22/2020. REMOVED CORRODED FS 319.70 FRAME BETWEEN STR 27 AND STR 26R AND REPLACED WITH NEW, REFERENCING CRJ 700 SRM. LEAK TEST GOOD. COMPLIED WITH SKYWEST TASK CARD.SDR SWAA2020100619626Frame · corrodedCORROSION ON FUSELAGE FRAME AT BS 947; S-25R WL 162. CORROSION ON FRAME FOUND TO BE OUT OF LIMITS DUE TO PROXIMITY TO FASTENER HOLES, PER SRM 53-00-07-1A-1 FIG 102 DETAIL C. REMOVED FRAME STR 23R-23L. LOCATED, DRILLED, & INSTALLED NEW FRAME, PER SRM 51-40-0SDR FDEA202009182346Frame · crackedLOWER FUSELAGE FR 40, CENTER WING JOINT FOUND LT MIDDLE HOLE WITH CRACK. SIGNAL COMPLIED WITH FEDEX EA: 6-5710-T0356552 PT1, EA TITLE: WINGS-BASIC WING STRUCTURE-CRACK IN THE HOLES AT FR 40 LT AND RT CENTER WING JOINT. REPAIRED LOWER FUSELAGE FR 40, CENTER WSDR FDEA202009182345Frame · crackedLOWER FUSELAGE FR 40, CENTER WING JOINT FOUND LT MIDDLE HOLE WITH CRACK. SIGNAL COMPLIED WITH FEDEX EA: 6-5710-T0356552 PT1, EA TITLE: WINGS-BASIC WING STRUCTURE-CRACK IN THE HOLES AT FR 40 LT AND RT CENTER WING JOINT. REPAIRED LOWER FUSELAGE FR 40, CENTER WSDR FDEA202009182342Frame · crackedLOWER FUSELAGE FR 40, CENTER WING JOINT FOUND LT UPPER HOLE WITH CRACK. SIGNAL COMPLIED WITH FEDEX EA: 6-5710-T0356552 PT1, EA TITLE: WINGS-BASIC WING STRUCTURE-CRACK IN THE HOLES AT FR 40 LT AND RT CENTER WING JOINT. REPAIRED LOWER FUSELAGE FR 40, CENTER WISDR FDEA202009182341Frame · crackedLOWER FUSELAGE FR 40, CENTER WING JOINT FOUND LT UPPER HOLE WITH CRACK. SIGNAL COMPLIED WITH FEDEX EA: 6-5710-T0356552 PT1, EA TITLE: WINGS-BASIC WING STRUCTURE-CRACK IN THE HOLES AT FR 40 LT AND RT CENTER WING JOINT. REPAIRED LOWER FUSELAGE FR 40, CENTER WISDR FDEA202009182340Frame · crackedLOWER FUSELAGE FR40, CENTER WING JOINT FOUND RT UPPER HOLE WITH CRACK. SIGNAL COMPLIED WITH FEDEX EA: 6-5710-T0356552 PT1, EA TITLE: WINGS-BASIC WING STRUCTURE-CRACK IN THE HOLES AT FR 40 LT AND RT CENTER WING JOINT. REPAIRED LOWER FUSELAGE FR 40, CENTER WINSDR DALA2020091903120Frame · crackedCRACK INDICATION ON FRAME 16 LT SIDE, DOOR STOP 7 HOLE ?1 AT FWD GALLEY AREA (1 EA), CRACK AT 5 O CLOCK. CORRECTIVE ACTION: REPLACED INTERCOSTAL ON FRAME 16 LT SIDE DOOR STOP 7 AT FWD GALLEY AREA, AS PER SRM A320 51-72-11 AND DRAWING D53112300 ISSUE "HOO" RELSDR DALA2020092103130Frame · crackedCRACK INDICATION ON FRAME 20 AT THE DOUBLE JOGGLE AREA, LT SIDE, HOLE. CORRECTIVE ACTION: REPAIRED FRAME 20 AT THE DOUBLE JUGGLE AREA LT SIDE HOLE A, AT LEVEL DOOR STOP 7 AT FWD GALLEY AREA, AS PER PRI 587474-14AD REV 0 1 AND ER/A 587474-14AD REV ORIGINAL.SDR DALA2020092103129Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE DOOR STOP 7 HOLE 3 AT FWD GALLEY AREA. CORRECTIVE ACTION: C/W ER/A 587495-14AD.SDR DALA2020092103128Frame · crackedCRACK INDICATION ON FRAME 16 RT SIDE DOOR STOP 7 HOLE ?1 AT FWD GALLEY AREA (1 EA), CRACK AT 8 O CLOCK, REQUESTING REPAIR DISPOSITION REPAIR. CORRECTIVE ACTION: REPLACED INTERCOSTAL FITTING ON FRAME 16 RT SIDE DOOR STOP 7 AT FWD GALLEY AREA (1E/A), AS PER PRISDR DALA2020091903111Frame · corrodedCORROSION LEVEL 2: DURING INITIAL INSPECTION FOUND CORROSION ON FRAME STA Y=1560 BETWEEN 4 RBL AND 14 RBL AT AFT CARGO COMPARTMENT. FRAME WAS REPAIRED PER ERA 587835-14.SDR DALA2020091903110Frame · dentedDURING INSPECTION FOUND FRAME DENTED BETWEEN AT STA 580, STR 22R-23R. FRAME DENTED, PER SRM 53-00-07.SDR SWIA202053904Frame · corrodedFRAME AT FS 333 CORRODED BETWEEN STGR 27 AND STGR 25L. C-CHECK RO 11/11/2020. DAMAGED FRAME SECTION WAS REMOVED AND NEW SECTION INSTALLED, IAW CRJ 200 SRM, NO CHANGE TO WEIGHT AND BALANCE. M-337 AND TASK CARD ATTACHED.SDR SWIA202053560Frame · crackedFRAME AT FS 333.0 STR 1L HAS CRACK. C-CHECK RO 10/20/2020. REMOVED FRAME SECTION AT FS 333.0 STR 1L, PER CRJ 200 SRM. REPLACED NEW FRAME SECTION AT FS 333.0 STR 1L, PER CRJ 200 SRM AND DWG. PRESSURE CHECKS GOOD.SDR DALA2023090807359Unknown · unknownSHIP 3278 A CRACK WAS FOUND IN FR 16 RHS AT HOLE B. CORRECTIVE ACTION: COMPLIED WITH ERA 587478-14AD. (1615327)SDR SWAA2021042718225Frame · damagedR/H FWD CARGO FRAME AT STA 420 BETWEEN STR22R - STR23R UPPER FLANGE WITH (2 EACH) ELONGATED HOLES AT FASTENER LOCATION. PREVIOUS REWORK NOT APPLICABLE PER SRM; REFERENCE N/R W50072 / CUTOUT DAMAGE AREAS AT FWD CARGO FRAME STA.420; BETWEEN STR21R - 24R; AND INSSDR DALA2020091653094Frame · damagedPERFORM IN FRAME 35 COLD WORK HOLE A AND HOLE B. CORRECTIVE ACTION: PERFORMED COLD WORK IN HOLE "A" AND HOLE "B" LOC FR 35 RT FWD CARGO COMPARTMENT (2 E/A), AS PER WORK CARD 5311-01171-03B, SB A320-53-1264, AND AD-2018-06-04.SDR SWIA202053476Frame · corrodedFRAME SECTOR FS 349 IS CORRODED BETWEEN STRINGERS 25L TO 26R. C-CHECK RO 10/18/2020. REMOVED AND REPLACED FRAME SECTOR FS 349 BETWEEN STRINGERS 25L AND 26R, IAW CRJ 200 SRM. REFERENCE ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.SDR SWIA202053387Frame · corrodedFRAME LOCATED AT FS 319.70 FROM STR 17L TO STR 21L IS CORRODED. C-CHECK RO 10/16/2020. REMOVED AND REPLACED FRAME AT FS 319.70 FROM STGR 17L TO STGR 21L, REF DWG CRJ-700 SRM. LEAK CHECK GOOD, NO DEFECT NOTED. COMPLIED WITH M337.SDR 2A6R2020091457401Frame · crackedDURING A 1000 HOUR INSPECTION FOUND THE LEFT 5 SIDE OF THE 5 ALPHA FRAME CRACKED. GOING TO REPLACE THE 5 ALPHA FRAME WITH P/N L533M1022966, PER SERVICE BULLETIN EC135-53-031.SDR REXA2020101300660Frame · corrodedFRAME AT FS 605 CORRODED BETWEEN STGR 18R AND STGR 24L. BLENDED AREAS ON 605 FRAME LISTED ABOVE, IAW CRJ 200 SRM 51-21-06, 53-61-15, 53-00-00 & 51-25-00. NO DEFECTS NOTED, WITHIN LIMITS.SDR SWIA202053318Frame · corrodedFRAME AT FS 333 IS CORRODED ON AFT SIDE AT STR 21L. C-CHECK RO 10/13/2020. REMOVED CORROSION AT FS 333 FRAME AT STGR 21L, FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW FRAME SECTION AT FS 333.00 FROM STGR 18L TO STGR 23L, REF CRJ200 SRM AND DWG. OPSSDR SWIA202053316Frame · corrodedFRAME FS 605 IS CORRODED BETWEEN STR 24L AND 27. C-CHECK RO 10/13/2020. BLENDED OUT CORROSION ON FS 605.00 FRAME FROM STGR 27 TO 24L, REF CRJ200 SRM. FOUND TO BE OUT OF LIMITS. REMOVED AND INSTALLED NEW LOWER FRAME SECTOR AT FS 605 FROM STR 20L TO STR 20R,SDR SWAA2021081715338Frame · crackedFOUND CAMLOCK RECEPTACLE FLANGE CRACKED OFF FROM THE MOST FORWARD SECOND ONE DOWN FROM PANEL 192BL.ACCOMPLISHED INTERIM REPAIR PER EA 20-153-01484. THIS IS A TEMPORARY REPAIR; REPAIR OR PORT REPLACEMENT MUST BE ACCOMPLISHED WITHIN 30 DAYS. P/N 149A7177-3 ACCO
Back to JASC 5311