JASC 5311
Service difficulty reports · 61,549
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014081101100Frame · crackedCRACKED FRAME STATION 380R, BETWEEN STRINGER 8R & 9R AROUND THE BUCKED TAIL OF THE INBD RIVET ATTACHING THE AC OUTLET EXTRUSION SUPPORT BRACKET. REPAIRED CRACKED AREA IAW EA 5310-04716 REV G OP 002 FIG 3.SDR CALA2014081191924Frame · damagedFUSE FRAME REPAIRS AT BS 1600, STRINGER 26L & BS 1320, STRINGER 28L WERE ACP.SDR SWAA2014090231509Frame · crackedFRAME OTBD CHORD FWD FLANGE CRACKED AT BS 727 STRINGER 18A RT. REPAIRED CHORD IAW EA.SDR SWAA2014090231508Frame · crackedFRAME OUTER CHORD CRACKED AT BS 727 STRINGER 18A RT. REPAIRED CHORD IAW EA.SDR FOTR20140828017Frame · crackedMAIN CABIN FRAME, BS 907 BELOW STRINGER 8R CRACKED. REPAIRED IAW FAS W/O N148AS-01-01.SDR FOTR20140828016Frame · crackedMAIN CABIN AT FRAME BS 380, BELOW STRINGER 8L CRACKED. REPAIRED IAW FAS N148AS-01-01.SDR FOTR20140823015Frame · crackedMAIN CABIN FRAME BS 827 BELOW STRINGER 8L CRACKED AROUND RIVET. REPAIRED ON FAS WO N148AS-01-01.SDR FOTR20140821013Frame · crackedMAIN CABIN AT FRAME BS 400 BELOW STG 8R AROUND RIVET CRACKED. REPAIRED ON FAS WO N148AS-01-01.SDR FOTR20140821011Frame · crackedMAIN CABIN AT FRAME BS 400 BELOW STG 8L AROUND RIVET CRACKED.SDR FDEA201408072104Frame · dentedCABIN LT STATION 1661 L12 FRAME FOUND DENT. DENTED AREA REPAIRED AS PER SRM 53-00-07 FIGURE 201 REPAIR 2 REVISION 56 REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 FLIGHT CYCLES, REPETITIVE INSPECTION AT 9,500 FLIGHT CYCLES TO BE CARRIED OUT AS SDR DALA2014080704465Frame · crackedCRACKED FRAME BS 1485. . REPAIRED IAW SRM 53-03-D, FIG 43.SDR CALA2014081101097Frame · crackedSTATION 400R BETWEEN STRINGER 8 & 9 AT THE AIR CONDITIONING OUTLET EXTRUSION SUPPORT ATTACHMENT TO THE FUSELAGE FRAME. THE INBD RIVET HOLE HAS A CRACK INDICATION ON THE FRAME. REMOVED FASTENER CUT OUT TWO EACH FASTENER HOLE FABRICATED REPAIR ANGLES & INSTALLSDR CALA2014081101096Frame · crackedSTATION 787R BETWEEN STRINGER 8 & 9 AT THE AIR CONDITIONING OUTLET EXTRUSION SUPPORT ATTACHMENT TO THE FUSELAGE FRAME. THE INBD RIVET HOLE HAS A CRACK INDICATION ON THE FRAME. CUT OUT DAMAGE & FABRICATED REPAIR ANGLES FOR FRAME 787 RT BETWEEN STRINGER 8R & 9SDR CALA2014081101095Frame · crackedSTATION 827R BETWEEN STRINGER 8 & 9 AT THE AIR CONDITIONING OUTLET EXTRUSION SUPPORT ATTACHMENT TO THE FUSELAGE FRAME, THE INBD RIVET HOLE HAS A CRACK INDICATION ON THE FRAME. CUT OUT DAMAGED FABRICATED REPAIR ANGLES & INSTALLED FRAME REPAIR ANGLES IAW EA 531SDR CALA2014081101094Frame · crackedAT STATION 400L BETWEEN STRINGER 8 & 9 AT THE AIR CONDITIONING OUTLET EXTRUSION SUPPORT ATTACHMENT TO THE FUSELAGE FRAME, THE FRAME HAS A CRACK INDICATION AT THE INBD ATTACH RIVET. REMOVED FASTENERS CUT OUT TWO EACH RIVET HOLES FABRICATED REPAIR ANGLES & INSTSDR CALA2014081101093Frame · crackedCRACK FOUND AT AFT FACE OF FRAME LOCATED ON STATION 480L BETWEEN STRINGER 8L & 9L WHERE AC SUPPORT BRACKET ATTACHED INBD FASTENER. REMOVED FASTENERS CUT OUT TWO EACH RIVET HOLES. FABRICATED REPAIR & INSTALLED REPAIR AT STATION 480 LT BETWEEN STRINGER 8L & 9LSDR CALA2014081191936Frame Splice · gougedBS 1520 FRAME SPLICE ABOVE STRINGER 23R, MULTIPLE GOUGES. FABRICATED & INSTALLED NEW SPLICE IAW DWG 146N1042 & SRM 51-30-01.SDR FDEA201408062083Frame · corrodedLOWER CARGO COMPARTMENT BILGE AREA AT STATION Y=1781 X=16 FRAME ANGLE FOUND CORROSION. ACCOMPLISHED REPAIR AS PER SRM 53-30-00 FIGURE 5 VOLUME I REVISION 101. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REVISION 122. TO PERFORM INITIAL INSPECTION AT 12,000 FSDR SWAA2014081130774Frame · crackedFRAME CRACKED AT BS 747 STRINGER 8R. REPAIRED FRAME IAW EA.SDR SWAA2014092432270Frame · crackedFRAME CRACKED AT BS 663.75 STRINGER 2R. REPAIRED FRAME IAW SRM.SDR SWAA2014092432269Frame · crackedFRAME CRACKED AT BS 663.75 STRINGER 3R. REPAIRED FRAME IAW SRM.SDR SWAA2014092432268Frame · crackedFRAME CRACKED AT BS 663.75 STRINGER 3L. REPAIRED FRAME IAW SRM.SDR ASOA2014082911147Frame · corrodedCORROSION AT BS 319, FRAME BETWEEN STRINGERS 26 - 27L. REMOVED CORROSION IAW SRM 51-21-06.SDR ASOA2014082711140Frame · corrodedCORROSION ON BS 333 FRAME FWD AND AFT SIDE BETWEEN STRINGER 25L - 26R. REMOVED CORROSION IAW SRM 51-21-06.SDR UIEA2014080700378Frame · damagedFRAME FWD CARGO COMPARTMENT STATION 980 STRINGER 46L - 47L. REPAIRED THE DAMAGE AREA IAW EI NO T2014A53B-2063 REV 1. CONDITION CHECKED NORMAL & JOB COMPLETED.SDR K11A2014120400001Frame · crackedCRACK ON LOWER AFT OTBD POCKET OF FRAME FITTING, LEFT.SDR SWAA2014082831382Frame · corrodedFRAME CORRODED AT BS 992.5 STRINGER 17R. REPAIRED FRAME IAW ER & EA.SDR CALA2014080401085Frame · crackedRIGHT FRAME STATION 727B SHOW CRACK INDICATION INBD SIDE FASTENER MFEC & HFEC INSPECTION. REMOVED DAMAGE & INSTALLED REPAIR DOUBLERS IAW EA 5310-04716 REV G.SDR CALA2014080401084Frame · crackedFRAME BETWEEN STRINGER 8L & 9L AT ACFT EXTRUSION SUPPORT ATTACHMENT AT STATION 400L INBD RIVET HAS A CRACK, RADIUS CHECK GOOD. REMOVED DAMAGE & INSTALLED REPAIR DOUBLERS IAW EA 5310-04716 REV G.SDR CALA2014080401081Frame · crackedFRAME BETWEEN STRINGER 8L & 9L AT ACFT EXTRUSION SUPPORT ATTACHMENT AT STATION 500A - L INBD RIVET HAS CRACK, RADIUS CHECKED GOOD. FRAME HAS BEEN REPAIRED IAW EA 5310-04716 REV G. SEE ALL TASKS & WIPS FOR WORK ACCOMPLISHED.SDR CALA2014080401080Frame · crackedRIGHT FRAME STATION 400 SHOW CRACK INBD SIDE FASTENER TO RADIUS VISUAL & HFEC INSPECTION. FRAME HAS BEEN REPAIRED IAW EA 5310-04716 REV G. SEE ALL TASKS & WIPS FOR WORK ACCOMPLISHED.SDR P5CA2014080400023Frame · crackedBULKHEAD FRAME WEB CRACKED AT STA 1480, LBL & NBSP; 110, WL 140, REPAIRED THE DAMAGED AREA IAW EI T2014A53B-2429, REV 2.SDR SWAA2014080830684Frame · crackedFRAME CRACKED AT BS 727D STRINGER 8L. REPAIRED FRAME IAW EA.SDR SWAA2014080730682Frame · crackedFRAME CRACKED AT BS 787 STRINGER 8L. REPAIRED FRAME IAW EA.SDR WVER0802201450905Frame · corrodedFOUND INTERGRANULAR CORROSION ON FRAME AT BS 379 AT STRINGER 23R.SDR REXA2014080100506Frame · corrodedFOUND CORROSION ON THE LOWER FRAME SECTOR AT FS 605.00 BETWEEN STRINGER 25R & 26L. REPAIRED IAW EA CRJ253-02772.SDR FDEA201407312014Spar Cap · crackedDURING HIGH FREQUENCY EDDY CURRENT INSPECTION OF RT WING, REAR SPAR LOWER CAP FOUND AROUND ONE FASTENER HOLE TO HAVE A CRACK INDICATION. REPAIRED IAW EA 8-5710-T0310288 REVISION A PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100 REVISION 123.SDR SWAA2014082531178Frame · crackedFRAME OUTER CHORD CRACKED AT BS 348.2 BETWEEN STRINGER 16L TO 17L. REPAIRED CHORD IAW EO & EA.SDR SWAA2014082531125Frame · crackedFUSELAGE FRAME CRACKED AT BS 520, BETWEEN STRINGER 20L TO 21L. REPAIRED FRAME IAW SRM.SDR GLBA2014073100425Frame · crackedDURING A SCHEDULED INSPECTION FOUND A CRACK IN THE FUSELAGE FRAME AT BS 183.25, BETWEEN STRINGERS 2 & 3R. CRACK RADIATES DOWNWARD FROM FASTENER, .2 INCHES IN LENGTH. REPAIRED IAW EO 14-1900-53-027. MAJOR REPAIR .SDR K11A2014120400003Frame · crackedFUSELAGE FRAME LOWER FARING LT W/W LOWER FITTING HAS CRACK AT UPPER END.SDR FDEA201407302011Frame · crackedBS 1681 STRINGER 7L FRAME INBD FLANGE AFT EDGE FOUND CRACKED. REPAIRED IAW EA F-5310-T0309884. CLASSIFIED AS MINOR.SDR CALA2014073101049Frame · crackedBS 400R FRAME CRACKED ON BRACKET FASTENERS BETWEEN STRINGERS 8 - 9R DOT 025. SDR FORM ATTACHED. ACCOMPLISHED REPAIR IAW EA 5310-04716 REV E, SEE BELOW STEPS. THIS IS A CATEGORY A REPAIR NO FURTHER INSPECTION REQUIRED.SDR SWAA2014081430853Frame · crackedFUSELAGE FRAME CRACKED AT BS 500B+5.5 INCHES, STRINGER 21L. REPAIRED FRAME IAW SRM.SDR SWAA2014081430852Frame · crackedFUSELAGE FRAME CRACKED AT BS 520+5.5 INCHES STRINGER 21L. REPAIRED FRAME IAW SRM.SDR CALA2014080191583Frame Splice · corrodedFORWARD PIT BS 660 LT, FRAME SPLICE PLATE CORROSION. REMOVED DAMAGE, FABRICATED & INSTALLED NEW SPLICE PLATE IAW SRM 51-40-05 & 51-40-02.SDR SWAA2014082531159Frame · crackedFRAME OTBD CHORD FWD FLANGE CHORD CRACKED AT BS 727 STRINGER 18A RT. R & R CHORD IAW EA.SDR SWAA2014082531158Frame · crackedFRAME OTBD CHORD FWD FLANGE CRACKED AT BS 727, STRINGER 18A LT. R & R CHORD IAW EA.SDR SWAA2014081230791Frame · crackedLEFT BS 500B+10 FRAME FOUND TO BE CRACKED AT HOLE NR 7R. R & R FORGING IAW DWG.SDR CALA2014072801028Frame · crackedSUPPORT TASK CABIN RT BS 480 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND THREE EACH CRACKS AT FRAME APPROX 1/4 INCHES, 1/4 INCH & 3/16 INCHES IN LENGTH. FRAME CRACKED AREA LENGTH 0.250. REPAIRED IAW EA 5310-04716 OP 1 REV G STEP 9 FIG 3 & FORM 4
Back to JASC 5311