What was found
CABIN LT STATION 1661 L12 FRAME FOUND DENT. DENTED AREA REPAIRED AS PER SRM 53-00-07 FIGURE 201 REPAIR 2 REVISION 56 REPETITIVE INSPECTION REQUIRED, INITIAL INSPECTION AT 14,500 FLIGHT CYCLES, REPETITIVE INSPECTION AT 9,500 FLIGHT CYCLES TO BE CARRIED OUT AS PER SRM 53-00-07 TABLE 201 REPAIR 2 REVISION 56. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REVISION 122.