SDR DALA2014070103933Frame · crackedCRACKED FRAME BS 1463 BETWEEN L8 - 9R. REMOVED IAW SRM 51-30-5. FABRICATED IAW DWG 9911839, REV DP. TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14, INSTALLED IAW SRM 51-30-5.Jun 30, 2014 · N969DL · Doug MD88SDR DALA2014070303921Frame · crackedCRACK ON FRAME BS 1380 AT LONGERON 15L . FRAME REMOVED IAW SRM 51-30-2 AND 51-30-5, NEW FRAME FABRICATED IAW DWG 9912246, REV CY. NEW FRAME WAS TREATED AND PAINTED IAW SRM 51-10-30, PAR 14 AND 21.Jun 30, 2014 · N969DL · Doug MD88SDR SWAA2014073030463Frame · crackedFRAME WEB CRACKED AT BS 492 STRINGER 24R. R & R WEB IAW SRM & EA.Jun 29, 2014 · N395SW · Boeing 7373H4SDR CALA2014063000849Frame · crackedSUPPORT TASK CABIN LT STATION 907L BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME APPROX BOTH 1/4 INCHES IN LENGTH. CABIN STATION 907 STRINGER 8L & 9L FRAME CRACKS AREA, CRACK LENGTH 0.25 INCHES. REPAIRED IAW ECRA 5310-06136 PAJun 29, 2014 · N14735 · Boeing 737724SDR SIMA20140628024Frame · crackedRIGHT CABIN FRAME NR 23, AT STRINGER 15 IS CRACKED. REPAIRED IAW EO EM-53MR-1808.Jun 28, 2014 · N845AE · Emb EMB135KLSDR SIMA20140628016Frame · crackedRIGHT AFT FUSELAGE FRAME 75 FASTENER HOLE CRACKED STRINGER 3 AREA MARKED. REPAIRED DAMAGE AT RT AFT FUSELAGE BY INSTALLING BUSHING IAW ERS-EM-5300-575. SEE TURNOVER FOR DETAILS.Jun 28, 2014 · N830AE · Emb EMB135KLSDR CALA2014063000847Frame · crackedSUPPORT TASK CABIN RT STATION 500A BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME APPROX 3/16 INCHES & 1/8 INCH IN LENGTH. CABIN STATION 500A BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.186. REPAIRED IAW EA 5310Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000846Frame · crackedSUPPORT TASK CABIN RT STATION 440R BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME BOTH APPROX 1/8 INCHES IN LENGTH. CABIN STATION 440 BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.125 INCHES. REPAIRED IAW EA 5310-Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000845Frame · crackedSUPPORT TASK CABIN RT STATION 500C BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND ONE EACH CRACK AT FRAME APPROX 1/8 INCHES IN LENGTH. CABIN STRINGER 500C BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.125 INCHES. REPAIRED IAW EA 5310Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000844Frame · crackedSUPPORT TASK FRAMES BETWEEN 8R & 9R ACFT BRACKET FOUND FRAMES CRACKED AT STATION 400R RADIUS INBD FASTENER. IAW EA 5310-040716 REV G NO CRACK RADIUS. INITIATED A DIP IAW ECRA5310-06138 PART 1 STEP 16. ACCOMPLISH INSPECTION REQUIREMENTS OF ECRA 5310-06138 ONJun 28, 2014 · N26208 · Boeing 737824SDR CALA2014063000843Frame · crackedSUPPORT TASK CABIN LT STATION 400 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND FOUR CRACKS AT FRAME APPROX 3/8 INCHES, 1/8 INCHES, 3/16 INCHES & 1/8 INCHES IN LENGTH. CABIN STATION 400 STRINGER 8L & 9L FRAME CRACKED AREA, CRACK LENGTH 0.375 INCHEJun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000842Frame · crackedSUPPORT TASK CABIN LT STATION 867L BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME APPROX BOTH 1/4 INCHES IN LENGTH. CABIN STATION 867 STRINGER 8L & 9L FRAME CRACKED AREA, CRACK LENGTH 0.250 INCHES. REPAIRED IAW EA5310-04716 OP Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000841Frame · crackedSUPPORT TASK FRAMES BETWEEN 8R & 9R ACFT BRACKET FOUND FRAMES CRACKED AT STATION 480R OTBD & INBD FASTENER. IAW EA 5310-040716 REV G NO CRACK RADIUS. INITIATED A DIP IAW ECRA5310-06138 PART 1 STEP 16. ACCOMPLISH INSPECTION REQUIREMENTS OF ECRA 5310-06138 ONJun 28, 2014 · N26208 · Boeing 737824SDR CALA2014063000840Frame · crackedSUPPORT TASK CABIN LT STATION 380 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME APPROX 1/4 INCHES & 1/8 INCHES IN LENGTH. CABIN STATION 380 BETWEEN STRINGER 8L & 9L FRAME CRACKED AREA, CRACK LENGTH 0.250 INCHES. REPAIRED IAW EJun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000838Frame · crackedSUPPORT TASK CABIN RT STATION 747R BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND ONE CRACK AT FRAME APPROX 0.030 INCHES IN LENGTH. CABIN STATION 747 BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.030 INCHES. REPAIRED IAW EA 5310-0471Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000837Frame · crackedSUPPORT TASK FRAMES BETWEEN 8R & 9R AC BRACKET FOUND FRAMES CRACKED AT STATION 440R INBD FASTENER. IAW EA 5310-040716 REV G NO CRACK RADIUS. INITIATED A DIP IAW ECRA 5310-06138 PART 1 STEP 16. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE ACFT REACHING 50Jun 28, 2014 · N26208 · Boeing 737824SDR CALA2014063000836Frame · crackedSUPPORT TASK FRAMES BETWEEN STRINGER 8R & 9R AC BRACKET FOUND FRAMES CRACKED AT STATION 867R INBD FASTENER IAW EA5310-040716 REV G NO CRACK ON RADIUS. INITIATED A DIP TO ACCOMPLISHED INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50.000 TOTAL FLIGHT Jun 28, 2014 · N26208 · Boeing 737824SDR CALA2014063000835Frame · crackedCABIN LT STATION 787L BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 1/4 INCHES & 3/16 INCHES IN LENGTH. CABIN STATION 787 BETWEEN STRINGER 8L & 9L FRAME CRACKED, CRACK LENGTH 0.250 INCHES. REPAIRED IAW ECRA 5310-04Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000834Frame · crackedCABIN LT STATION 480 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 1/4 INCHES & 3/16 INCHES IN LENGTH. CABIN LT STATION 480 BETWEEN STRINGER 8L & 9L FRAME CRACKED AREA, CRACK LENGTH 0.250 INCHES. REPAIRED IAW EA531Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000833Frame · crackedCABIN RT STATION 400R BETWEEN STRINGER 8 & 9 INBD HOLES OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME APPROX 3/8 INCHES & 1/4 INCHES IN LENGTH. CABIN STATION 400 BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.250 INCHES. REPAIRED IAW ECRA 53Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000832Frame · crackedCABIN RT STATION 480R BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO EACH CRACKS AT FRAME BOTH APPROX 1/4 INCHES IN LENGTH CABIN STATION 480 RT BETWEEN STRINGER 8R & 9R FRAME CRACKED AREA, CRACK LENGTH 0.250 INCHES. REPAIRED IAW ER EA 5310-0471Jun 28, 2014 · N14735 · Boeing 737724SDR CALA2014063000831Frame · crackedCABIN LT STATION 440 BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND 2 EACH CRACKS AT FRAME APPROX 3/8 INCHES & 3/8 INCHES IN LENGTH CABIN STATION 440 BETWEEN STRINGER 8L & 9L. FRAME CRACKED AREA CRACK LENGTH 0.375 INCHES REPAIRED IAW EA 5310-04716 Jun 28, 2014 · N14735 · Boeing 737724SDR DALA2014063003830Frame · crackedAFT ACCESSORY COMPARTMENT FRAME, BS 1458, CRACKED AT LONGERON 1. CUT OUT DAMAGE AND FABRICATED AND INSTALLED FILLER, ANGLE AND WATER SEPARATOR BRACKET IAW SRM 53-10-02, 51-10-03, AND 51-30-05.Jun 28, 2014 · N916DN · Doug MD9030SDR ASOA20140628163Frame · crackedDURING C-CHECK, FRAME 10R CRACKED UNDER DV WINDOW. R & R FRAME IAW SRM 51-40-02. ACFT WAS APPROVED FOR RETURN TO SERVICE.Jun 28, 2014 · N13936 · Emb EMB145EPSDR SWIA201438672Frame · chafedCHAFE DAMAGE ON FRAME BS 280, BETWEEN S2 - 3L. C-CHECK, FABRICATED REPAIR STRAP IAW EA.Jun 27, 2014 · N909SW · Cndair CL6002B19SDR DALA2014063003832Frame · wornFUSELAGE FRAME IS WORN AT LT SIDE 10:00 POSITION APPROXIMATELY 48 INCHES AFT OF AFT PRESSURE BULKHEAD. REPAIRED IAW SRM 53-10-02, FIG 2.Jun 27, 2014 · N919DN · Doug MD9030SDR 7AHR201406302293Frame · corrodedFWD CARGO BAY BS 446 FRAME HAS CORROSION ON AFT SIDE AT STRINGER ATTACH POINT. CORROSION REMOVED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-01, PG 8. FABRICATED AND INSTALLED REPAIR IAW SRM 53-03, FIG 2A, CONF 7013.Jun 27, 2014 · N120MN · Doug DC983SDR SIMA20140627003Frame · crackedFRAME 23 CRACKED BETWEEN STRINGER 15R & 16R. REPAIRED FRAME 23 BETWEEN STRINGER 15R & 16R IAW EM-53MR-1808.Jun 27, 2014 · N833AE · Emb EMB135KLSDR SWAA2014072830384Frame · crackedRIGHT FRAME INNER CHORD CRACKED AT BS 616 WL 200. REPAIRED CHORD IAW EA.Jun 26, 2014 · N399WN · Boeing 7373H4SDR A6WA201441764Frame · corrodedLOWER FRAME SECTOR AT FS 319 IS CORRODED FROM STRINGER 26L TO 26R.Jun 26, 2014 · N444ZW · Cndair CL6002B19SDR SWAA2014070329625Frame · crackedFUSELAGE FRAME CRACKED AT STATION 348.2, STRINGER 16L. REPAIRED FRAME IAW EA.Jun 26, 2014 · N508SW · Boeing 7375H4SDR SIMA20140626002Frame · crackedDURING HMBV INSPECTION, QA FOUND TWO CRACKED FASTENER HOLES ON FRAME 75 BETWEEN STRINGERS 2R & 3R. ACFT WAS REMOVED FROM SERVICE FOR HMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER HMBV INSPECTION. PERFORMED PERMANENT REPAIR ON TWO CRACKED FASTENER HOLES Jun 26, 2014 · N644AE · Emb EMB145LRSDR CALA2014062791349Frame · dentedDENT ON AFT CARGO FRAME UPPER SFC AT BS 1580 JUST ABOVE STRINGER 26L. REMOVED DAMAGE. HFEC. FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-07 REPAIR 5.Jun 26, 2014 · N528UA · Boeing 757222SDR FOTR20140808008Frame · corrodedAFT CARGO BAY UPPER SURFACE FLANGE OF FRAME, BS 787, STRINGER 25L HAS CORROSION. REPAIRED ON FAS WO N455KA-01-01, NR 64337.Jun 25, 2014 · N455KA · Boeing 73742CSDR A6WA201441770Frame · corrodedLOWER FRAME SECTOR CORRODED AT FS 333 FROM STRINGER 26L TO 26R.Jun 25, 2014 · N444ZW · Cndair CL6002B19SDR DALA2014062803850Frame · crackedCRACK ON FRAME, BS 1510, AFT FACE 1 O`CLOCK POSITION, AFT ACCESSORY BAY. FRAME REMOVED AND REPLACED IAW SRM 53-14-4, FIG 3.Jun 25, 2014 · N969DL · Doug MD88SDR QXEA2014070100538Rib · corrodedRIBS CORRODED AT 88.30 AND 64.20. LOCATED AND DRILLED TWO NEW RIBS IAW SRM 51-40-07, REPAIR 01. REMOVED REMOVED AND REPLACED IAW SRM 51-42-05.Jun 25, 2014 · N437QX · Bombdr DHC8402SDR DALA2014062603819Frame · corrodedAFT CARGO FORMER CORRODED MULTIPLE LOCATIONS, BS 1344, LONGERON 26L TO 26R. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW FORMER IAW DWG 9957739, REV DL.Jun 25, 2014 · N916DN · Doug MD9030SDR CALA2014062791347Frame · dentedAFT CARGO PIT STATION 1560 JUST ABOVE STRINGER 16R. DENT IN STRUCTURE MAIN FRAME UPPER SURFACE. REMOVED DAMAGE. HFEC FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-00-07T.Jun 25, 2014 · N528UA · Boeing 757222SDR DALA2014062603797Frame · crackedCRACK ON FRAME BS 446 BETWEEN LONGERONS 19 - 20RT. DAMAGE WAS REMOVED AND NEW SECTION OF FRAME WAS INSTALLED IAW SRM 53-03D, FIG 2A.Jun 25, 2014 · N963DL · Doug MD88SDR ASOA20140625144Frame · crackedDURING C-CHECK, FRAME 66 WAS FOUND TO BE CRACKED AT STRINGER 16R. MAINTENANCE PERFORMED A DOUBLER REPAIR IAW SRM 53-00-04. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jun 25, 2014 · N14933 · Emb EMB145ERSDR FDEA201406241542Frame · crackedFUSE UPPER LOBE STATION 1681 FRAME HAS 5 INCH CRACK ABOVE SPLICE AT L13R. REMOVED CRACKED SECTION OF FRAME AND REPAIRED PER SRM 53-30-00 FIG 5 SHEET 1 VOLUME 1.Jun 24, 2014 · N358FE · Doug MD1010FSDR CALA2014062791357Frame · corrodedAFT CARGO COMPARTMENT FLOOR SUPPORT, FRAME UPPER J FLANGE, IS CORRODED UNDER NUTPLATE BS 1131 & RBL 33. REMOVED UPPER FLANGE, FABRICATED A NEW INNER CHORD ANGLE IAW DWG 146T6511 & INSTALLED IAW SRM 51-40-2 ON NON-ROUTINE.Jun 24, 2014 · N653UA · Boeing 767322SDR ASOA20140624139Frame · crackedDURING C-CHECK, FRAME 10 BROKEN, TOP AFT OF FRAME, ON CO-PILOT SIDE. MAINTENANCE R & R FRAME IAW SRM 51-40-02. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.Jun 24, 2014 · N10156 · Emb EMB145XRSDR ASOA2014071610883Frame · corrodedFRAME BS 319 CORRODED ON AFT SIDE BETWEEN STRINGERS 26 AND 27L. REMOVED CORROSION IAW SRM 51-21-06-001-001-A01 & 53-21-06-101-002-A02. COMPLIED WITH REO 690-53-21-659. MAJOR REPAIR.Jun 23, 2014 · N186PQ · Cndair CL6002D24SDR CALA2014062500812Frame · crackedFRAME 500C RT CRACKED AT INBD RIVET ATTACHING THE BRACKET TO THE FRAME BETWEEN STRINGER 8R - 9R. REMOVED BRACKET AT FRAME 500C RT BETWEEN STRINGER 8R - 9R IAW SRM 51-40-02 TO GAIN ACCESS TO REPAIR. CUT OUT CRACK AT TWO FASTENERS AT FRAME 500C BETWEEN STRINGEJun 23, 2014 · N14250 · Boeing 737824SDR SIMA20140623005Repair · chafedDURING HMBV INSPECTION, QA FOUND A CHAFE ON A PREVIOUS REPAIR TO FRAME 19 BETWEEN STRINGERS 3R & 4R. ACFT WAS REMOVED FROM SERVICE FOR HMBV INSPECTION & WILL BE RETURNED TO SERVICE AFTER HMBV INSPECTION. R & R PREVIOUS REPAIR ON FRAME 19 BETWEEN STRINGERS 3R Jun 23, 2014 · N644AE · Emb EMB145LRSDR CALA2014062300810Frame · crackedSUPPORT TASK LT FRAME AT BS 480 BETWEEN STRINGER 8 - 9 SUPPORT BRACKET ATTACHMENT AREA FOUND INBD RIVET HOLE CRACKED AT FRAME LAYER APPROX 3/16 INCHES LONG RUNNING INBD & UPPER & OTHER ONE APPROX 1/16 INCHES LONG RUNNING INBD & LOWER. CABIN LT FRAME AT BS 480Jun 23, 2014 · N14249 · Boeing 737824SDR CALA2014062300809Frame · crackedSUPPORT TASK RT FRAME AT STATION 400 BETWEEN STRINGER 8 - 9 SUPPORT BRACKET ATTACHMENT AREA FOUND INBD RIVET HOLE CRACKED AT FRAME LAYER APPROX 1/8 INCH LONG RUNNING UP & APPROX 1/8 INCH LONG RUNNING DOWN. CABIN RT FRAME AT STATION 400 BETWEEN STRINGER 8 - 9 Jun 23, 2014 · N14249 · Boeing 737824SDR CALA2014062300808Frame · crackedSUPPORT TASK LT FRAME AT BS 440 BETWEEN STRINGER 8 - 9 SUPPORT BRACKET ATTACHMENT AREA FOUND INBD RIVET HOLE CRACKED AT FRAME LAYER APPROX 1/4 INCH LONG RUNNING INBD & UPPER & OTHER ONE APPROX 3/16 INCHES LONG RUNNING INBD & LWR. CABIN LT FRAME AT BS 440 BIN Jun 23, 2014 · N14249 · Boeing 737824
Back to JASC 5311