What was found
SUPPORT TASK CABIN LT STATION 907L BETWEEN STRINGER 8 & 9 INBD HOLE OF SUPPORT BRACKET FOUND TWO CRACKS AT FRAME APPROX BOTH 1/4 INCHES IN LENGTH. CABIN STATION 907 STRINGER 8L & 9L FRAME CRACKS AREA, CRACK LENGTH 0.25 INCHES. REPAIRED IAW ECRA 5310-06136 PART 1 & ATTACHED FORM 44.0008 ITEMS 1-19 ACCOMPLISHED. CREATED A DIP IAW ECRA 5310-06 136 PART 2 53-DIP CNTL 27926 FOR INSP. ACCOMPLISH INSPECTION REQUIREMENTS IAW ECRA 5310-06136 PART 2 ON OR BEFORE THE ACFT REACHING 40,000 TOTAL FLT CYCLES. PLANNING ON CONTACTING ENGINEERING AFTER 33,000 CYCLES BUT BEFORE 34,000 TOT FLT CYCLES FOR INSPECTION REQUIREMENTS.