JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C2XA04SH395Doubler · corrodedSHV - DURING C-CHECK THE DOUBLER AT FRAME 20 WAS FOUND TO BE CORRODED AROUND THE NUT PLATES. MAINTENANCE REMOVED AND REPLACED THE DOUBLER IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA200419602Frame · dentedABI - DURING AN HMBV INSPECTION, CARGO AREA FRAME 677 WAS FOUND TO HAVE THREE SMALL DENTS. RECONTOURED THE THREE DENTS ON FRAME 677 AND PERFORMED AN EDDY CURRENT INSPECTION WITH NO REJECTABLE INDICATIONS. FABRICATED ANGLE REPAIR DOUBLER. REPAIR DONE IAW SAABSDR 2004UALA00611Frame · dentedFRAME DENTED ON INBD FLANGE STA 1480, STR 25L. MAJOR REPAIR ACCOMPLISHED. REPAIRED FRAME WITH NESTED J-ANGLE.SDR SWAA041774Frame · corrodedDURING SCHEDULED D-CHECK, FOUND FRAME WEB AT BS 986 TO BS 992, RBL 46, CORRODED. REMOVED AND REPLACED FRAME WEB SECTION PER SRM.SDR ASAA0440138Frame · corrodedOAK - FOUND AFT CARGO COMPARTMENT, FRAME AT STATION 767 CORRODED ON FORWARD SIDE FROM STRINGER 25R TO BL 0. REPAIRED FRAME IAW SRM 53-00-07 PAGE 210-212. (M)SDR IXXA060119SFrame · crackedDURING ROUTINE C-CHECK FOUND FRAME CRACKED AT STATION 1580 LONGERON 21 LEFT. REMOVED FASTENER AS NEEDED TO REMOVE DAMAGED FRAME SECTION. FABRICATED REPAIR PARTS, LOCATED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED REPAIR PARTS AND NEW FASTENERS AT STATIONSDR IXXA060118SFrame · crackedDURING ROUTINE C-CHECK FOUND FRAME CRACKED AT STATION 1580 LONGERON 21 RIGHT. REMOVED FASTENER AS NEEDED TO REMOVE DAMAGED FRAME SECTION. FABRICATED REPAIR PARTS, LOCATED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED REPAIR PARTS AND NEW FASTENERS AT STATIOSDR 2004UALA00607Frame · dentedFRAME DENTED STA 1580 ABOVE STR 25L ON INBD FLANGE. *S/D* MAJOR REPAIR ACCOMPLISHED. FRAME REPAIRED WITH A NESTED J-ANGLE.SDR 2004UALA00606Frame · dentedFRAME IS DENTED STA 1500, STR 25L ON INBD FLANGE. *S/D* MAJOR REPAIR ACCOMPLISHED. FRAME REPAIRED WITH NESTED J-ANGLE.SDR 2004UALA00605Frame · dentedFRAME AT STA 1540 ABOVE STR 25L IS DENTED, INBD FLANGE. *S/D* MAJOR REPAIR ACCOMPLISHED. NESTED J-ANGLE REPAIR.SDR 2004UALA00604Frame · dentedFRAME DENTED ON INBD FLANGE, BS 1400 STR 25L. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED A NESTED J-ANGLE REPAIR.SDR 2004UALA00603Frame · dentedAFT PIT FUSELAGE FRAME IS DENTED AT STA 1440 LT AT FLOOR TRANSITION PANEL. DAMAGE IS ON INBOARD FLANGE IN TWO PLACES. MAJOR REPAIR ACCOMPLISHED. INSTALLED J-ANGLE REPAIR.SDR SWAA041752Frame · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FRAME AT BS 787, STRINGER 22L TO STRINGER 25L, CORRODED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA041739Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAMES AT BS 907, BS 867, BS 827, BS, 787, STRINGER 8L, BS 907, BS 867, BS 787, STRINGER 8R, CRACKED. REMOVED AND REPLACED FRAME SECTIONS PER SRM.SDR 2004UALA00600Frame · crackedSTA 663 FRAME HAS 4 CRACKS, 2 EACH AT THE STR 3 RT LIGHTENING HOLE, AND 1 EACH AT THE STR 1 AND 2 RT LIGHTENING HOLE. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE AND REMOVED STRINGER SPLICES FOR ACCESS, INSTALLED REPAIR ANGLE DOUBLER AND STRINGER SPLICES.SDR SWAA041742Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME AT BS 360, STRINGER 8R, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA041741Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAME AT BS 400, STRINGER 8R, CRACKED. REMOVED AND REPLACED FRAME SECTION PER SRM.SDR SWAA041740Frame · crackedDURING SCHEDULED D-CHECK, FOUND FRAMES AT BS 747, STRINGER 8R AND STRINGER 8L, CRACKED. REMOVED AND REPLACED FRAME SECTIONS PER SRM.SDR ASOA04443Frame · crackedDURING A C-CHECK IN THE MCN, THE RIGHT FRAME FS 718, STRINGERS 10-11 ON THE AFT SIDE WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE RIGHT FRAME FS 718, STRINGERS 10-11 ON AFT SIDE IAW ASA EO 600-53-0066. (M)SDR AWXA200400721Frame · crackedMCN - MAJOR REPAIR - DURING C-15 CHECK A 1.5 INCH CRACK WAS FOUND IN INBOARD LEG OF LT FRAME AT BS 616, LBL 65, WL 201. MAINTENANCE CUT OUT DAMAGED PORTION OF INNER CHORD AT BS 616, LBL 65, WL 201 AND PREFORMED A HFEC INSPECTION OF CUTOUT TO VERIFY NO CRACKS SDR IXXA060275SFrame · corrodedDURING ROUTINE C CHECK, FOUND FRAME CORRODED AT STATION 188 BETWEEN LONGERONS 3 RIGHT AND 11 RIGHT, ALSO 3 LEFT AND 11 LEFT. REPAIRED PER ALL APPLICABLE DATA.SDR SWAA041716Frame · crackedDURING SCHEDULED 1/2D CHECK, FOUND FRAME AT BS 340, STRINGER 23L, CRACKED. REPAIRED FRAME SECTION PER SRM.SDR 04FDEA01793Frame · chafedFRAME FOUND CHAFED MARK AT STA 535 LONGERON R19-24.SDR 04FDEA01792Frame · dentedMAIN DECK FRAME FOUND DENT AT STA 535 LONGERON L19-24.SDR NACA20040051Frame · crackedRT FUSELAGE CIRCUMFERENTIAL AT STA. R460 CRACKED APPROXIMATELY 3 INCHES ABOVE FLOOR LEVEL. REPLACED ANGLE WITH THE SAME TYPE AND MATERIAL .090 7075 T6. FABRICATED AND INSTALLED REPAIR (L) AND STRAP WITH REFERENCE TO DOHM FIG. 11-52 AND FIG. 12-10 SHEET 2.SDR AALA20040797Frame · cutAFW - WHILE ACCOMPLISHING C1945CB STEP E 3 CHORD WAS CUT AT 0.30 INCH FROM UPPER FASTENER OF REMAINING CHORD NOT 0.46 INCH AS ECO INSTRUCTS. AREA IS 1 INCH BY 1 INCH AT A DEPTH OF 1.3 INCHES. FILLED GAP WITH BMS5 95 SEALANT AND COMPLETED REPAIR PER ECO C1945SDR AALA20040702Frame · cutAFW - WHILE ACCOMPLISHING C1945CB STEP E3 FRAME WAS CUT AT .30 INCH FROM UPPER FASTENER OF REMAINING FRAME, NOT .46 INCH AS ECO STATES. AREA WAS ONE INCH BY ONE INCH AT A DEPTH OF 1.3 INCHES. FILLED GAP WITH BMS595 SEALANT AND COMPLETE REPAIR PER ECO C1945 ISDR IXXA060358SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y600 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060357SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y380 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060274SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y1280 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060273SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y1120 AT LONGERON 14 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060272SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y902 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060271SFrame · tool damageDURING ROUTINE C CHECK, FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y860 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060270SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y834 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060269SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y781 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060268SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y500 AT LONGERON 14 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060267SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y660 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060266SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y600 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060265SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y560 AT LONGERON 14 RIGHT. REPAIRED PER ALL PPLICABLE DATASDR IXXA060264SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y500 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060263SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y420 AT LONGERON 7 RIGHT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060262SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y1120 AT LONGERON 7 LEFT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060261SFrame · misdrilledDURING ROUTINE C CHECK FOUND FRAME FLANGE WITH A DOUBLE DRILLED HOLE AT STATION Y834 LONGERON 7 LEFT. REPAIRED PER ALL APPLICABLE DATA.SDR IXXA060260SFrame · misdrilledDURING ROUTINE C CHECK FOUND DOUBLE DRILLED HOLE IN FRAME FLANGE AT STATION 640, LONGERON 7 LEFT. REPAIRED PER ALL APPLICABLE DATASDR IXXA060259SFrame · misdrilledDURING ROUTINE C CHECK FOUND DOUBLE DRILLED HOLES AT STATION 600 AT LONGERONS 7 LEFT AND 14 LEFT. REPAIRED PER ALL APPLICABLE DATA.SDR UPS04842745Frame · corrodedINSPECTION TYPE: C-3, STA 35 AT LONGERON 22R CORRODED AT FRAME. REMOVED FRAME SECTION TO FOM FAB NEW FRAME SECTION AND SPLICES INSTALLED NEW FRAME SECTION AND SPLICES IAW DAC DWG 5613836 AND REO GO9859 AND DC8 SRM 51-1-21, 51-1-20D, 51-1-8.SDR 04FDEA01741Frame · crackedFOUND FRAME BS 783 RT FASTENER HOLE CRACKED. REPAIR PER EO 7-5310-7-3367 PART 9. REPAIRED FRAME BS 783 RT PER EO 7-5310-7-3367 PART 9.SDR COMA0460370Frame · crackedFRAME RADIUS CRACKED ABOVE STRINGER 10 AT LEFT HAND FS 718. FRAME RADIUS CRACKED BELOW STRINGER 11 AT LEFT HAND FS 718. PREVIOUS REPAIR HOLE PATTERN BETWEEN STRINGER 10 AND 11 WILL NOT ALLOW FOR EO 53-027. REMOVED AND REPLACED SECTION OF FS 718.00. COMPLIESDR DL73S040560Frame · dentedINNER FLANGE OF FRAME AT STATION 500 DENTED BETWEEN STRINGERS 24R AND 25R. AREA REPAIRED IAW 090636-14.SDR SWAA041695Frame · crackedDURING SCHEDULED D-CHECK, FOUND FUSELAGE FRAME CRACKED AT BS 747, STR 9R. REPAIRED FRAME PER SRM.
Back to JASC 5311