As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFW - WHILE ACCOMPLISHING C1945CB STEP E3 FRAME WAS CUT AT .30 INCH FROM UPPER FASTENER OF REMAINING FRAME, NOT .46 INCH AS ECO STATES. AREA WAS ONE INCH BY ONE INCH AT A DEPTH OF 1.3 INCHES. FILLED GAP WITH BMS595 SEALANT AND COMPLETE REPAIR PER ECO C1945 INSTRUCTIONS.