JASC 5313
Service difficulty reports · 36,310
Reports filed under 5313 · Fuselage Main, Longeron/Stringer, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL2007746532Stringer · corrodedFORWARD CARGO COMPARTMENT, STRINGER 27L IS CORRODED WITH EXFOLIATION FROM BODY STA 720F +10 INCHES TO BODY STA 740. CUT OUT DAMAGED SECTION OF STRINGER 27L STA 720F +10 TO 740 IAW B727 SRM 53-10-3 FIG 1, 10" LONG. REMOVED CORROSION ON SKIN IAW B727 SRM 51-10SDR SWAA074280Stringer · crackedDURING SCHEDULED 20Y CHECK, FOUND STRINGER 15L CRACKED AT BS 360. REPAIRED STRINGER PER SRM.SDR 07FDEA03224Longeron · corrodedHEAVY CORRODED LONGERON BETWEEN FRAME 11-15A, CABIN FLOOR STRUCTURE. INSTALLATION OF NEW LONGERON IAW SRM 53-12-15 / FIG 207.SDR 07FDEA03219Stringer · corrodedAFT PIT STRINGER 55L BETWEEN FRAMES 54.2 AND 54.3 CORRODED LEFT SIDE COMPLIED WITH EA 6-5310-112955 FUSELAGE AFT PIT STRINGERS P52L, P54L, P55L REPAIR.SDR 07FDEA03217Longeron · corrodedFWD CARGO COMPT BILGE AREA FOUND SEVERE CORROSION ON LONGERON. REPAIRED LONGERON IAW SRM 53-10-00 VOL I FIG 1& 2.SDR 07FDEA03209Stringer · corrodedFOUND CORROSION ON STRG 56 RT, FRAME 57.3-61. REPAIR PERFORMED BY REMOVAL OF CORROSION AND ROTO TEST IAW EA 6-5317-112511 AND RAS/DATLS/003803/2007 ISS "A".SDR 07FDEA03208Stringer · corrodedFOUND CORROSION ON STRG 56 LT, FRAME 57.3-61. REPAIR PERFORMED BY REMOVAL OF CORROSION AND ROTO TEST IAW EA 6-5317-112511 AND RAS/DATLS/003803/2007 ISS "A".SDR 07FDEA03207Stringer · corrodedFOUND CORROSION ON STRG. 56 LT, FRAME 57.3-61. REPAIR PERFORMED BY REMOVAL OF CORROSION AND ROTO TEST IAW EA 6-5317-112511 AND RAS/DATLS/003803/2007 ISS "A".SDR COEA0705900Stringer · corrodedFOUND LEVEL 2 CORROSION IN HEAVY CHECK: STRINGER 16L BETWEEN FRAME 9 AND 10 HAS CORROSION ON LOWER FLANGE. REMOVED AND REPLACED NEW STRINGER 16L SECTION BETWEEN FRAME 9 AND 10. (K)SDR SWAA074254Stringer · crackedDURING SCHEDULED 18Y CHECK, FOUND STRINGER 15L CRACKED AT BS 380. REPAIRED STRINGER PER SRM.SDR 07FDEA03191Stringer · corrodedCORROSION AT STRG 50, BETWEEN FRAME 39-43 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03190Stringer · corrodedCORROSION AT STRG 48, BETWEEN FRAME 40-44 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03189Stringer · corrodedCORROSION AT STRG 47, BETWEEN FRAME 39-42 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03188Stringer · corrodedCORROSION AT STRG 46, BETWEEN FRAME 39-42 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03187Stringer · corrodedCORROSION AT STRG 44, BETWEEN FRAME 40-45 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03186Stringer · corrodedCORROSION AT STRG 40-41, BETWEEN FRAME 40-45 RT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03185Stringer · corrodedCORROSION AT STRG 50, BETWEEN FRAME 46-47 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03184Stringer · corrodedCORROSION AT STRG 49, BETWEEN FRAME 39-44 LH. REMAINING THICKNESS OUT OF LIMIT, STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03183Stringer · corrodedCORROSION AT STRG 49, BETWEEN FRAME 39-44 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03182Stringer · corrodedCORROSION AT STRG 48, BETWEEN FRAME 39-42 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03181Stringer · corrodedCORROSION AT STRG 46 AND 50, BETWEEN FRAME 39-42 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03180Stringer · corrodedCORROSION AT STRG 46, BETWEEN FRAME 39-42 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03179Stringer · corrodedCORROSION AT STRG 45, BETWEEN FRAME 39-42 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03178Stringer · corrodedCORROSION AT STRG 44, BETWEEN FRAME 39-44 LT. REMAINING THICKNESS OUT OF LIMIT. STRINGER REPAIR PERFORMED WITH PRINCIPLE DESCRIBED IN SRM 53-10-14/FIG 201A, APPROVED BY EA 6-5315-103260 AND RAS/046453/012/2006 ISS "A".SDR 07FDEA03175Stringer · damagedBS 740, VERTICAL ANGLE AND BULKHEAD SKIN, ABOVE STR S-28 HAS 2 EA PLUG RIVETS THROUGH ALL PARTS (PREVIOUS DAMAGE) ACCOMPLISHED WORK INSTRUCTION ON EA NR 7-5310-11068 FOR REPAIR OF 2 (EA) PLUG RIVETS THROUGH VERTICAL ANGLE, AND BULKHEAD.SDR USAA070671Stringer Splice · crackedSTA 360 S14L, STRINGER SPLICE HAS CRACK. DRILLED UP NEW PART & INSTALLED PER SRM 51-40-02, DEFECT SIZE: .500 INCH.SDR CALA0700461Stringer · corrodedINSPECTION FOUND STRINGER 26R CORRODED AT STA 986.5. A STRINGER SPLICE WAS INSTALLED IAW SRM 53-00-03.SDR 07FDEA03157Longeron · crackedHFEC INSPECTION CARRIED OUT FOUND 01 EACH LOWER FASTENER HOLE ON THE LONGERON WITH CRACK INDICATION LOCATED NEAR THE RIGHT NOSE LANDING GEAR TRUNNION FITTING, APPROX TOTAL LENGTH OF 3/8 INCH LENGTH. 09-12-07 LONGERON LOCATED NEAR THE RIGHT HAND NOSE LANDINSDR 07FDEA03156Longeron · crackedHFEC INSPECTION CARRIED OUT FOUND 01 EACH LOWER FASTENER HOLE ON THE LONGERON WITH CRACK INDICATION LOCATED NEAR THE LEFT NOSE LANDING GEAR TRUNNION FITTING, APPROX TOTAL LENGTH OF 1/2 INCH LENGTH. 09-12-07 COMPLIED WITH FEDEX E.A. 1-5310-115173, REPAISDR 07FDEA03152Stringer · corrodedCORROSION ON STRG 59 BETWEEN FRAME 55/58-59, REMAINING THICKNESS OUT OF LIMIT. CONNECTING SECTION REPAIRED IAW SRM 53-10-14/FIG 201.SDR 07FDEA03149Stringer · corrodedCORROSION ON STRG 56 LHS BETWEEN FRAME 72-73, REMAINING THICKNESS OUT OF LIMIT. STRINGER SPLICE REPAIR PERFORMED IAW SRM 53-10-14/FIG 201.SDR 07FDEA03148Stringer · corrodedCORROSION ON STRG 55 LHS BETWEEN FRAME 75-76, REMAINING THICKNESS OUT OF LIMIT. STRINGER SPLICE REPAIR PERFORMED IAW SRM 53-10-14/FIG 201.SDR 07FDEA03147Stringer · corrodedCORROSION FOUND ON STRG 56 LT AND RT OUTER FLANGE BETWEEN FRAME 76-77. REPAIR PERFORMED BY CUT STRINGER OUTER FLANGES P56 LT, ROTO TEST OF OPEN FASTENER HOLES, CORROSION REMOVAL ON SKIN, FLAP PEENING AT SKIN REWORKED AREAS AND INSTALLING REPAIR ANGLE IAW EA 6SDR 2007UALA03396Stringer · damagedSTA 340 STRINGER 23R IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: INSTALLED DOUBLER REPAIR.SDR DHL2007746526Stringer · corrodedSURFACE CORROSION ON EXISTING STRINGER SPLICE BODY STA 1010 FORWARD AND AFT OF STR 27L (MARKED). REMOVED SPLICE AT BODY STATION 1010 FORWARD AND AFT STR 27L IAW B727 SRM 51-30-2. FABRICATED SPLICE MATERIAL USED BAC1498-131 7075-T6 PO NR 9003866 DIMENSION 12 SDR 07FDEA03121Stringer · crackedLWR FWD CARGO PIT FUSELAGE STRINGER UPPER O/B FLANGE HAS CRACK, STA 720 PLUS 14.5" STR 25R. REMOVED DAMAGE REF SRM 53-10-3. FABRICATED REPAIR REF SRM 53-10-3 FIG 2, SHEET 2. INSTALLED REPAIR REF 51-30-2 PG 1, PG 1-3, THIS IS CLASSIFIED AS A MAJOR REPAIR.SDR COEA0716821Stringer · corrodedFOUND DURING HEAVY CHECK. MAJOR REPAIR, FOUND LEVEL 2 CORROSION ON STRINGER 18L. FABRICATED REPLACEMENT STRINGER SECTION. (K)SDR HNAA0700190Stringer Splice · corrodedCORROSION FOUND ON SPLICE STRINGER 32 RIGHT SIDE AT STA 531. SPLICE STRINGER 32 RIGHT AT 531 REPLACED WITH NEW PART LOCALLY MADE AS PER DWG 85300129 AND INSTALLED.SDR 07FDEA03115Stringer Splice · corrodedAFT PIT BILGE BODY FRAME STR SPLICE IS CORRODED, BS 1008-1012, STR 29L, WL 140. REMOVED STRINGER SPLICE, CLEANED DAMAGE HOLE, HFEC STRINGER, FABRICATED STRINGER SPLICE. FABRICATED STRINGER CLIPS, TREATED AND PRIMED PARTS, PERFORMED HIDDEN DAMAGE INSPECTION. SDR SWAA074194Stringer · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER 21L CORRODED AT BS 370. REPAIRED STRINGER PER SRM.SDR SWAA074195Stringer · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER 25R CORRODED AT BS 350. REPAIRED STRINGER PER SRM.SDR SWAA074188Stringer · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER 21L CORRODED AT BS 500A. REPAIRED STRINGER PER SRM.SDR SWAA074196Stringer · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER 20R CORRODED AT BS 500C. REPAIRED STRINGER PER SRM.SDR SWAA074193Stringer Splice · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER SPLICE CORRODED AT BS 360, STR 23L. REMOVED AND REPLACED STRINGER SPLICE PER SRM.SDR SWAA074192Stringer Splice · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER SPLICE CORRODED AT BS 360, STR 26R. REMOVED AND REPLACED STRINGER SPLICE PER SRM.SDR SWAA074190Stringer Splice · corrodedDURING SCHEDULED SPV CHECK, FOUND STRINGER SPLICE CORRODED AT BS 360, STR 25R. REMOVED AND REPLACED STRINGER SPLICE PER SRM.SDR CALA0700455Stringer · corrodedINSPECTION FOUND S27L CORRODED AT STA 957. THE STRINGER WAS REPAIRED IAW SRM 53-00-03.SDR PIDR07003Stringer · damagedSTRINGER 16 RT AT BS 727B HAS A DAMAGED FASTENER HOLE. REPAIRED IN ACCORDANCE WITH SRM 53-10-3 FIGURE 2.SDR 07FDEA03109Stringer · corrodedAFT CARGO PIT, STR 54L CORRODED BETWEEN FR 58 AND FR61 (STA X3143 AND STA X3302) CUT OUT CORRODED SECTION OF STR 54L FROM STA X3143 TO STA X3302. FABRICATED AND SPLICED IN REPAIR SECTION IAW A310-200 SRM 53-10-14 FIG 201, 51-21-10 AND 51-23-10.SDR 07FDEA03108Stringer · corrodedAFT CARGO PIT, STR 45R CORRODED, FR 54.2 TO FR 54.3 (X3037 TO X3090) CUT OUT CORRODED SECTION OF STRINGER 45R, FROM STA X2984 TO X 3090, FABRICATED AND SPLICED IN REPAIR SECTION, IAW A310-200 SRM 53-10-14 FIG 201, 51-71-30 FIG 202, 51-40-21 PAR 6, 51-21-10 AN
Back to JASC 5313