What was found
LWR FWD CARGO PIT FUSELAGE STRINGER UPPER O/B FLANGE HAS CRACK, STA 720 PLUS 14.5" STR 25R. REMOVED DAMAGE REF SRM 53-10-3. FABRICATED REPAIR REF SRM 53-10-3 FIG 2, SHEET 2. INSTALLED REPAIR REF 51-30-2 PG 1, PG 1-3, THIS IS CLASSIFIED AS A MAJOR REPAIR.