JASC 5313
Service difficulty reports · 36,313
Reports filed under 5313 · Fuselage Main, Longeron/Stringer, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5313' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA990502Longeron · crackedPIT - DURING Q-4 CHECK, FOUND 1 INCH CRACK IN LONGERON AT STATION 980, LONGERON 17L. SPLICED IN LONGERON PER SRM 53-02. (M)SDR USAA990501Longeron · crackedPIT - DURING Q-4 CHECK, FOUND 1 INCH CRACK AT LONGERON 9R CANTED STATION 1046. SPLICED IN LONGERON PER SRM 53-02 FIG 18. (M)SDR USAA990499Longeron · crackedPIT - DURING Q-4 CHECK, FOUND 1 INCH CRACK IN LONGERON AT STATION 965, LONGERON 17 UPPER AND LOWER LEGS. INSTALLED SPLICE REPAIR PER SRM 53-04 FIG 18. (M)SDR USAA990492Longeron · crackedPIT - DURING Q-4 CHECK, FOUND TWO .5 INCH CRACKS AT LONGERON ATTACH POINTS, STATION 718 LONGERON 6 LT. SPLICED IN NEW SECTION OF LONGERON PER SRM 53-02, FIG 18 SHEET 1. (M)SDR USAA990491Longeron · crackedPIT - DURING Q-4 CHECK, FOUND .5 INCH CRACK AT LONGERON 2L, STATION 756. CUT OUT DAMAGED SECTION AND INSTALLED LONGERON REPAIR SECTION AND SPLICED PER SRM 53-02 FIG 18. (M)SDR USAA990490Longeron · crackedPIT - DURING Q-4 CHECK, FOUND .5 INCH CRACK AT LONGERON 5 LEFT, STATION 699. CUT OUT DAMAGED SECTION AND INSTALLED LONGERON REPAIR SECTION AND SPLICES PER SRM 53-02 FIG 18. (M)SDR UPS99229880Stringer · corrodedINSPECTION TYPE: C & SI, SURFACE CORROSION ON STRINGER 23R NESTING SECTION AT BS 448 APPROX. NESTING SECTION REPLACED IAW SRM 53-10-02 FIG AND SRM 53-10-3 FIG 1.SDR UPS99229879Stringer · crackedINSPECTION TYPE: C & SI, SUSPECT CRACK ON STRINGER 21R NESTING SECTION AT BS 448 APPROX. NESTING SECTION REPLACED IAW SRM 53-10-02.SDR ABXA9900425Longeron · crackedDURING C-CHECK, FOUND LONGERON 17 LEFT CRACKED AT STATION 980. REPLACED LONGERON 17 LEFT IAW DC9 SRM 51-30-5.SDR 99ZZZM663Stringer · corrodedSPECIAL STRINGER ON LOWER KEEL BEAM, RIGHT SIDE HAS CORROSION BETWEEN FRAMES 24A RT AND 27A RT. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND BEYOND LIMITS IAW 26 PERCENT MATERIAL THICKNESS SRM 53-51-00 PAGE 304. (M)SDR 99ZZZM662Stringer · corrodedSPECIAL STRINGER ON LOWER KEEL BEAM, LEFT SIDE HAS CORROSION BETWEEN FRAMES 24A LT AND 27A LT. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND BEYOND LIMITS IAW 32 PERCENT MATERIAL THICKNESS SRM 53-51-00 PAGE 304. REMOVED AND SDR UPS99229882Stringer · crackedINSPECTION TYPE: C & SI, STRINGER 23 CRACKED BS 380, 400 AND 420 AT FRAME ATTACH POINTS LT SIDE. STRINGER REPAIRED IAW 53-10-3 FIG 1.SDR UPS99229881Stringer · crackedINSPECTION TYPE: C & SI, SUSPECT CRACK AT STR 25 RT BS 420 AT FRAME ATTACH POINT ON STRINGER LWR FASTENER HOLE. STRINGER REPAIRED IAW SRM 53-10-3 FIG 1.SDR UPS99229866Stringer · crackedINSPECTION TYPE:C&SI STR CRACKED BS 380 AND 400 AT FRAME ATTACH POINTS RT SIDE. REPAIRED IAW SRM 53-10-3 FIG 1.SDR UPS99229850Stringer · corrodedINSPECTION TYPE:C&SI, FWD CARGO BAY BS 490 CORROSION ON STRINGER 21R. REPLACED WITH NEW PIECE IAW SRM 53-10-3 FIG 1.SDR SWAA990953Stringer · crackedDURING SCHEDULED 1/2D CHECK, FOUND STRINGER 6L CRACKED AT BS 1016. REPAIRED STRINGER PER SWA RA NR 1-353-2088.SDR RRXA991102Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, LONGERON 36 BETWEEN STA 1726 AND STA 1745. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. INSTALLED REPAIR SPLICE IAW DC8 SRM 53-2-1 AND 51-1-21. (CORROSION DAMASDR MWEA99311Longeron · corrodedAFT ACCESS LONGEORN 17R HAS LIGHT CORROSION AND TOOL MARKS ON LOWER SIDE OF LOWER LEG BETWEEN FRAME 1089-1104. REMOVED CORROSION BLENDED TOOL MARKS, FABRICATED NEW SECTION OF THE LONGERON.SDR DL72S991341Stringer · damagedFOUND DURING MV2 CORROSION VISIT NRC 128, CUT FRAME STA 990 TO ACCESS REPAIR OF STR 29 LT REF NRC 89. REPAIRED PER M/M 53-12-0 FIG 805. WORKED WITH NRC 93, 94, 213.SDR DL72S991342Stringer · crackedFOUND DURING MV2 CORROSION VISIT NRC 89, 1 IN CRACK STR 29 LT AT STA 1000. REPLACED STR 29 LT STA 980 TO STA 1007 PER SRM 53-10-11 FIG 3. WORKED WITH NRC 93, 94, 128, 213.SDR AALA990804Skin · corrodedTUL - FOUND CORROSION ON FUSE INTERIOR SKIN STATION 685, OUTBOARD STRINGER 27R. CUT OUT CORRODED SKIN TO SPLICE AND REPAIRED WITH DOUBLERS PER SRM 53-30-3. (M)SDR AALA990802Stringer · corrodedTUL - FOUND CORROSION IN STRINGER 26 LEFT, STATION 690. CUT OUT DAMAGED SECTION OF STRINGER 2. INSTALLED NEW SECTION PER SRM 53-10-3 FIGURE 1. (M)SDR UPS99229919Stringer · corrodedINSPECTION TYPE: C & SI, FWD CARGO BAY CORROSION ON STRINGER 23L AT BS 540 TO BS 560. REPAIR CARRIED OUT IAW SRM 51-10-6 & SRM 53-10-3 FIG 2.SDR RRXA991535Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, TO LONGERON 30 RIGHT, SPLICE DOUBLER BETWEEN STA 600 AND STA 620. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE DOUBLER IAW DSDR QXEA9901176Stringer · corrodedPDX - STRINGER 41 FORWARD END, 2.5 INCHES AFT OF FRAME 4900 HAS EXFOLIATION CORROSION. REPAIRED IAW FOKKER SRM 53-02-06, FIGURE 1E.SDR AALA990801Stringer · corrodedTUL - FOUND CORROSION AROUND RIVETS ALONG BOTTOM OF STRINGER STATION 660-700. REPAIRED PER SRM 51-10-3 FIG 1. (M)SDR USAA990483Stringer · corrodedTPA - DURING CX-4 CHECK, FOUND 8 INCHES OF STRINGER WEB CORRODED AT STRINGER 27R AT STATION 967 THROUGH 975. REPLACED STRINGER PER SRM 53-00-03. (M)SDR QXEA9901298Stringer · crackedPDX - CRACK AT INSULATION ATTACH HOLE ON STRINGER 46, FORWARD OF FRAME 7305. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR QXEA9901225Stringer · crackedPDX - LEFT-HAND FORWARD CABIN STRINGER 34 HAS TWO CRACKS AT INSULATION HOLES, 1.7 FORWARD OF FRAME 7805 AND 3.9 FORWARD OF FRAME 7805. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR QXEA9901210Stringer · corrodedPDX - STRINGER 30 CORROSION AT CRACKED INSULATION FASTENER HOLE, 1.7 AFT FRAME 8305. REPAIRED IAW FOKKER SRM 53-02-06, FIGURE 1BB.SDR QXEA9901205Stringer · crackedPDX - STRINGER 34 CRACKED AT INSULATION FASTENER HOLE, 1.7 AFT FRAME 8305. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR QXEA9901204Stringer · crackedPDX - STRINGER 34 CRACKED A INSULATION FASTENER HOLE, 8.8 AFT FRAME 8305. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR QXEA9901185Stringer · crackedPDX - STRINGER 46 HAS CORROSION/CRACK AT HOLE, 2.8 INCHES AFT OF FRAME 8305. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR QXEA9901183Stringer · crackedPDX - STRINGER 46 HAS CORROSION/CRACK AT HOLE, 10 INCHES AFT OF FRAME 8305. REPAIRED IAW FOKKER SRM 53-02-06, PAGE 3.SDR ABXA9900426Longeron · crackedDURING C-CHECK, FOUND LONGERON 17 RIGHT CRACKED AT STATION 256. REPAIRED IAW DC9 SRM 53-02.SDR ABXA9900389Longeron · crackedDURING C-CHECK, FOUND LONGERON 17 LEFT CRACKED AT STATION 294, 275 AND 256. REPAIRED LONGERON 17 LEFT IAW DC9 SRM 53-02.SDR UPS99229862Stringer · corrodedINSPECTION TYPE:C&SI AFT CARGO BAY CORROSION ON STRINGER 19 R AT BS 1080. REPAIR CARRIED OUT IAW SRM 51-10-6, 53-10-1 AND 51-10-02 AND DRAWING 65-18385.SDR TWAA9907708Longeron · crackedFOUND LONGERON 5L AT FS 699 CRACKED .25 INCH. FABRICATED AND INSTALLED LONGERON AND SPLICES IN LONGERON 5L AT FS 699 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.SDR TWAA9907707Longeron · crackedFOUND LONGERON 4R AT FS 756 CRACKED .25 INCH. CUT OUT DAMAGED SECTION AND REPAIRED LONGERON PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.SDR TWAA9907706Longeron · crackedLONGERON 6R AT FS 756 WAS CRACKED .25 INCH. REPAIRED LONGERON 6R AT FS 756 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.SDR TWAA9907703Longeron · crackedLONGERON 5L FS 639 WAS CRACKED .25 INCH. REPLACED SECTION ON LONG 5L AND INSTALLED SPLICE SECTION PER SRM 53-02, FIG 18 AND SRO9530128 DRAWING. CHECK-C 11-13-98 STL.SDR QXEA9901297Stringer · damagedPDX - CASTELLATION FLANGE REMOVED TO FACILITATE STRINGER REPAIRED AT STRINGER 34 AND FRAME 5805. FABRICATED REPAIR ANGLE IAW FOKKER SRM 53-02-12, FIGURE 1.SDR AALA99803Stringer · corrodedTUL - FOUND CORROSION IN STRINGER 27 RIGHT STATION 500-520. INSTALLED STRINGER REPAIR IAW SRM 53-10-3 FIG 1. (M)SDR TWAA9907705Longeron · crackedFOUND .25 INCH CRACKS AT LONGERON 6L AT FS 737 AND 756, AND LONGERON 7R AT FS 680. REPAIRED EACH PER SRM 53-02 FIG 18, AND SRO 9530128. CHECK-C 11-13-98 STL.SDR TWAA9907704Longeron · crackedLONGERON 6L AT FS 658 WAS CRACKED .25 INCH LONG. REPAIRED PER SRM 53-02, FIG 18 AND STANDARD PRACTICES. CHECK-C 11-13-98 STL.SDR QXEA9901187Stringer · corrodedPDX - DOME NUT PLATE 4 AFT OF FRAME 9305C AT STATION 10753 ON STRINGER 37 HAS SURFACE CORROSION. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 8, PARAGRAPH 3C, SRM 51-31-01 PAGE 13, PARAGRAPH B.SDR SWAA990928Stringer · corrodedDURING SCHEDULED RON CHECK, FOUND CRACKS THROUGH EDDY CURRENT INSPECTION AT STRINGERS 6L, AND 6R, AT BULKHEAD STA 1016. REPAIRED STRINGERS PER SWA RA NR 1-353-2086.SDR SWAA990926Stringer · corrodedDURING SCHEDULED RON CHECK, FOUND CORROSION AT STRINGER 28L, BETWEEN BS 947-1006. REPAIRED STRINGER PER SRM.SDR RRXA991615Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, SKIN BETWEEN STA 35 AND STA 80 AND LONGERON 32 RIGHT, CORROSION BULGE WITH PULLING FASTENERS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION IAWSDR QXEA9901296Stringer · corrodedPDX - MID CABIN, STRINGER 38 HAS CORROSION AROUND HOLE, 5.5 AFT OF FRAME 11405 AT STATION 12853. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 8, PARAGRAPH 3C.
Back to JASC 5313