What was found
FOUND LONGERON 5L AT FS 699 CRACKED .25 INCH. FABRICATED AND INSTALLED LONGERON AND SPLICES IN LONGERON 5L AT FS 699 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LONGERON 5L AT FS 699 CRACKED .25 INCH. FABRICATED AND INSTALLED LONGERON AND SPLICES IN LONGERON 5L AT FS 699 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.