SDR SWAA2022101078888None · corrodedCORROSION BEAM FLOOR STRUCTURE LOCATED BS986.5 LBL45 WL208.1 AT AFT GALLEY AREA 2022-486067 / [01] TOOL USED : DIGITAL CALIPER ; P/N 8647A42; S/N B22058408; DUE DATE: 27/AUG/23; DEPTH GAGES P/N 20915A21 S/N 009295 DUE DATE 06/JUL/23;[02] ET TOOL USED: PN: MIZ-SDR SWAA2022101046635None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 RBL 11 WL 208.1 AT FWD GALLEY AREA 2022-486065 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.;[02] REFER TO FAULT TTG8Q00ELB7L WHERSDR SWAA2022101078891Support · corrodedCORROSION FLOOR STRUCTURE SUPPORT BEAM LOCATED BS986.5 RBL45 WL208.1 AT AFT GALLEY AREA 2022-486072 / [01] TOOL USED : DIGITAL CALIPER ; P/N 8647A42; S/N B22058408; DUE DATE: 27/AUG/23; DEPTH GAGES P/N 20915A21 S/N 009295 DUE DATE 06/JUL/23;[02] TOOL USED THICSDR SWAA2022101078893Beam · corrodedCORROSION FLOOR STRUCTURE SUPPORT BEAM LOCATED BS986.5 LBL30 WL208.1 AT AFT GALLEY AREA 2022-486069 / [01] TOOL USED : DIGITAL CALIPER ; P/N 8647A42; S/N B22058408; DUE DATE: 27/AUG/23; DEPTH GAGES P/N 20915A21 S/N 009295 DUE DATE 06/JUL/23;[02] PERFORMED PERMSDR SWAA2022100646632None · corrodedCORROSION FLOOR BEAM LOCATED BS328 AND RBL45.5; WL208.1 AT FWD GALLEY AREA 2022-486053 / [01] TOOL USED:P/N FPK-PRO-104 S/N PRO-3447 CAL DUE DATE:27 JUN 23;[02] TOOL USED TEMPERATURE CONTROLLER P/N:P3015GOES00000;S/N:142811020;DUE DATE:02-FEB-23.P/N:48VFL11;S/SDR SWAA2022100646633None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 LBL 10 WL 208.1 AT FWD GALLEY AREA 2022-486063 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.;[02] TOOL USED RADIUS GAGE P/N:S167C SDR SWAA2022100650218None · corrodedCORROSION BEAM FLOOR STRUCTURE LOCATED BS986.5 LBL45 WL208.1 AT AFT GALLEY AREA 2022-486067 / [01] TOOL USED : DIGITAL CALIPER ; P/N 8647A42; S/N B22058408; DUE DATE: 27/AUG/23; DEPTH GAGES P/N 20915A21 S/N 009295 DUE DATE 06/JUL/23;[02] ET TOOL USED: PN: MIZ-SDR SWAA2022100650207None · corrodedCORROSION FLOOR BEAM LOCATED BS 344 BTW RBL 1 TO LBL 1 AND WL 208.1 AT FWD GALLEY AREA 2022-486057 / [01] TOOL USED: ET EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; CAL DUE DATE: 03-DEC-22;[02] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 11203102SDR SWAA2022100650224None · corrodedCORROSION FLOOR STRUCTURE SUPPORT BEAM LOCATED BS986.5 LBL30 WL208.1 AT AFT GALLEY AREA 2022-486069 / [01] TOOL USED : DIGITAL CALIPER ; P/N 8647A42; S/N B22058408; DUE DATE: 27/AUG/23; DEPTH GAGES P/N 20915A21 S/N 009295 DUE DATE 06/JUL/23;[02] PERFORMED PERMSDR SWAA2022100650213None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 LBL 10 WL 208.1 AT FWD GALLEY AREA 2022-486063 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.;[02] TOOL USED RADIUS GAGE P/N:S167C SDR SWAA2022100678884None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 LBL 6 WL 208.1 AT FWD GALLEY AREA 2022-486064 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.SDR SWAA2022100678885None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 RBL 11 WL 208.1 AT FWD GALLEY AREA 2022-486065 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.SDR SWAA2022100678883None · corrodedCORROSION FLOOR BEAM LOCATED BS 312 LBL10 WL 208.1 AT FWD GALLEY AREA 2022-486062 / [01] TOOL USED RADIUS GAGE P/N:S167C S/N:AE-28524 DUE DATE:29/AUG/23;[02] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 112031023 DUE DATE: 01-FEB-23. TEMPERATURE COSDR SWAA2022100646634None · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 LBL 6 WL 208.1 AT FWD GALLEY AREA 2022-486064 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.;[02] REFER TO FAULT TTG8Q00ELB7L WHERESDR SWAA2022093050212Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS 312 LBL10 WL 208.1 AT FWD GALLEY AREA 2022-486062 / [01] TOOL USED RADIUS GAGE P/N:S167C S/N:AE-28524 DUE DATE:29/AUG/23SDR SWAA2022093050214Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 LBL 6 WL 208.1 AT FWD GALLEY AREA 2022-486064.SDR SWAA2022093050215Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS 294.5 RBL 11 WL 208.1 AT FWD GALLEY AREA 2022-486065 / [01] TOOL USED CALIPER P/N 500-196-30; S/N 14333669 CAL DUE DATE 14-JUN-23; DEPTH GAGE P/N 20915A21; S/N 009295 CAL DUE DATE 03 JUL 23.SDR AALA202209273983Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR BEAM AT FR 20 AND -Y1292. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA202209208390Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN FLOOR BEAM BETWEEN FR 64 AND FR 66 AT -Y765. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR SWAA2022100378977None · crackedCRACK FLOOR BEAM LOCATED BS294.5 AND RBL52 AT FWD GALLEY AREA 2022_488660 / [01] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X12101V022240. DUE DATE: 27-JAN-23.;[02] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X11290U021704.SDR SWAA2022100378968None · corrodedCORROSION FLOOR BEAM LOCATED BS312 AND LBL15; WL208.1 AT FWD GALLEY AREA 2022-488668 / [01] TOOL USED: ULTRASONIC EQUIPMENT; P/N: 45 MG; S/N: 130066701; DUE DATE: 08-APR-23.;[02] TOOL USED PN ULTRASONIC EQUIPMENT PN:45MG; SN: 130066701; DUE DATE: 08-APR-23<BR>SDR SWAA2022100378984None · corrodedCORROSION FLOOR BEAM LOCATED BS 986.5 AND LBL44; WL208.1 AT PASSENGER CABIN 2022-488708 / [01] TOOL USED EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D; SN: 210138203; CAL DUE DATE: 11-APR-23;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 2101SDR SWAA2022100378987None · corrodedCORROSION FLOOR BEAM LOCATED BS986.5 AND RBL44; WL208.1 AT PASSENGER CABIN 2022-488718 / [01] TOOL USED EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D; SN: 210138203; CAL DUE DATE: 11-APR-23;[02] TOOL USED: FLAPSPEED; PN: FPK-PRO-104; SN: PRO-3344; DUE DATE: 06-MASDR SWAA2022100349999None · crackedCRACK FLOOR BEAM LOCATED BS294.5 AND RBL52 AT FWD GALLEY AREA 2022_488660 / [01] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X12101V022240. DUE DATE: 27-JAN-23.;[02] TOOL USED. EDDY CURRENT EQUIPMENT. P/N: NORTEC 500D. S/N: N500X11290U021704.SDR SWAA2022100349989None · corrodedCORROSION FLOOR BEAM LOCATED BS312 AND LBL15; WL208.1 AT FWD GALLEY AREA 2022-488668 / [01] TOOL USED: ULTRASONIC EQUIPMENT; P/N: 45 MG; S/N: 130066701; DUE DATE: 08-APR-23.;[02] TOOL USED PN ULTRASONIC EQUIPMENT PN:45MG; SN: 130066701; DUE DATE: 08-APR-23<BR>SDR SWAA2022100350005None · corrodedCORROSION FLOOR BEAM LOCATED BS 986.5 AND LBL44; WL208.1 AT PASSENGER CABIN 2022-488708 / [01] TOOL USED EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D; SN: 210138203; CAL DUE DATE: 11-APR-23;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600 D; S/N: 2101SDR SWAA2022100350008Bracket · corrodedCORROSION FLOOR BEAM LOCATED BS986.5 AND RBL44; WL208.1 AT PASSENGER CABIN 2022-488718 / [01] TOOL USED EDDY CURRENT FLAW DETECTOR PN: NORTEC 600D; SN: 210138203; CAL DUE DATE: 11-APR-23;[02] TOOL USED: FLAPSPEED; PN: FPK-PRO-104; SN: PRO-3344; DUE DATE: 06-MASDR SWAA2022101045315None · corrodedCORROSION ON BS986 FLOOR BEAM AT LBL42. / [01] CORROSION ON BS 986 FLOOR BEAM AT LBL 42 FOUND 100% OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE ON THE PREVIOUS REPAIR. THE STRUCTURAL ITEM WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02 PAR 9C;13] FABRICATED -SDR SWAA2022101049112None · corrodedCORROSION ON BS986 FLOOR BEAM AT LBL42. / [01] CORROSION ON BS 986 FLOOR BEAM AT LBL 42 FOUND 100% OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE ON THE PREVIOUS REPAIR. THE STRUCTURAL ITEM WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02 PAR 9C12] INSPECTED ACTSDR F3LA2022091200100Floorbeam · corrodedDISCREPANCY: REFERENCE PEMCO N/R#12767.0339 FWD CABIN FLOOR BEAM Y503.2 CORRODED FROM 12 TO FR16
CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM Y503.2 IAW A320 SRM 51-42-11, SRM 53-11-14-283-007 FR-12-16SDR SWIA202266867Floorbeam · corrodedR/H SILL, FLOOR SUPPORT STRAP IS CORRODED ON UPPER SURFACE AT FS 559.00 BETWEEN RBL 29 TO RBL 43. (C-CHECK RO 11/12/2022) REPLACED FLOOR SUPPORT STRAP ON RH SILL AT FS559 BETWEEN RBL29 TO RBL43 PER BOMBARDIER DRAWING 601R31025 (REV N) AND CRJ200SRM 51-4SDR SWAA2022100645277None · corrodedCORROSION ON AFT PASSENGER CABIN FLOOR BEAM AT BS 986 LBL 42; RBL 42. / [01] AFTER FURTHER INVESTIGATION FOUND NO CORROSION DAMAGE AT RBL 42 ( BARE METAL ONLY);[02] VERIFIED CORRECTIVE ACTION 1.;[03] APPLIED A CHEMICAL CONVERSION COATING AND TWO LAYERS OF BMS SDR AALA202209065905Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON UPPER FLANGE OF FLOOR BEAM AT STA 947.5 AND LEFT BUTT LINE 8. INSTALLED ANGLE DOUBLERS AND STRAPS PER SRM 53-00-51-2R-1.SDR ASAA2022082740016Floorbeam · corrodedFLOORBEAM 986.5 HAS CORROSION BETWEEN RBL 45.5 AND 60.75. GROUNDED - YES. BLENDED CORROSION FOUND TO BE OUT OF LIMITS REPAIRED FLOOR BEAM IAW B737-700 SRM 53-70-51-2R-4.W= 1.0 O= .150 R= .142 L= 2.1 D= .008.SDR SWAA2022100346682None · corrodedCORROSION SPOTS ON CABIN FLOOR BEAM UPPER CAP B.S. 986.5 RBL. 29'-45' W.L 208. / [01] REMOVED CORROSION ON FLOOR BEAM UPPER CAP STA. 986.5 RBL; 29AND RBL 45; WL 208 PER REF SRM 51-10-02-0G-0;[07] REMOVED FLOOR BEAM INTERCOSTAL; BETWEEN STA. 986.5 AND STA; 1006SDR ASAA2022082640021Frame · corrodedAFT CARGO L/H TRANSITION FROM FS 727A TO 807 HAS AREAS OF CORROSION. GROUNDED - YES. BLENDED CORROSION AREAS FRAM STA 727A TO 727D+13, REMAINING MATERIAL FOUND OUT OF LIMITS IAW B737-700 SRM 53-00-53-1A-2. REPAIRED SECTION IAW B737-700 SRM 53-00-53-2R-5. BLENDSDR SWAA2022092646381None · corrodedCABIN AFT WET AREA FLOOR BEAM AT STA 986 LBL 45 UPPER T CHORD SHOWS AREAS OF CORROSION / [01] REMOVED CORROSION AT CABIN FLOOR BEAM AT STA 986 LBL 45 AS PER B737-700 SRM 51-10-02-0G-0-A00248;[02] VERIFIED STEP 1;[03] PERFORMED UT THICKNESS INSP ON REWORKED ARESDR SWAA2022092645575None · corrodedFWD WET AREA FLOOR BEAM STA 294.5 LBL 11 HAS CORROSION. / [01] INSTALLED EWIS PROTECTION AT FLOOR BEAM STA 294.5 LBL11 AREA . REF<BR>20-60-07-913-801;[02] REMOVED CORROSION AT FWD WET AREA FLOOR BEAM STA 294.5 LBL 11 SRM 51-10-02-0G-0; [14] FABRICATED SPLICE ASDR SWAA2022092645578None · corrodedFWD WET AREA FLOOR BEAM STA 312 LBL 12 HAS CORROSION / [01] INSTALLED PROTECTION EWIS AT FWD WET AREA BETWEEN STA 294.5 TO STA 328 AMM 20-60-07-913-801;[02] REMOVED CORROSION AT FWD WET AREA FLOOR BEAM STA 312 LBL 12 ;EXPLOITED CORROSION AREA FOUND OUT LIMITS SDR SWAA2022092645461None · corrodedCORROSION ON 947 FLOORBEAM UPPER SURFACE FROM LBL 24-LBL 27; WL 208. / [01] UPDATED MEASUREMENTS. APPLICABILITY STATEMENT FOR ALLOWABLE DAMAGE PER SRM 53-70-51-1A-1. BLENDED CORROSION AT BS 947 LBL 24-LBL27 WL 208 AND THE DEEPEST REMOVED IS 1.0X0.5X0.035' FOUNSDR CALA2022082402157Floorbeam · elongatedELONGATED HOLE FLOOR BEAM -Y1292 LOC. FR64 TO FR66 AT AFT GALLEY AREA.SEE AEROMAN NON ROUTINE 2022-393856. INSTALLED NEW FLOOR BEAM Y1292 LOC FR64 TO FR 66 AT AFT GALLEY AREA I.A.W. A320 SRM 51-42-11, DWG #D53472201 AND DWG #D534722 00. PERFOMED SCPETRE ENTRY SDR SWAA2022092765237None · corrodedCORROSION ON PASSENGER CABIN FLOOR BEAM UPPER SURFACE AT STA 727A+18; LBL 23; WL 208. / [01] REMOVED CORRODED FILLER FOR LONGITUDINAL BEAM BS 727A+18; LBL 23; WL 208 PER SRM 51-40-02; FABRICATED REPLACEMENT FROM 7075T6-C#.090' LOT# 1482311 AS SHOWN ON EA 1-757SDR SWAA2022092765238Floor Panel · corrodedCORROSION ON PASSENGER CABIN FLOOR BEAM UPPER SURFACE AT STA 727A+17 TO 727A+19; RBL 44.5; WL 208. / [01] REMOVED CORRODED FILLER FOR LONGITUDINAL BEAM BS 727A+17 TO BS 727A+19; RBL 44.5; WL 208 PER SRM 51-40-02; FABRICATED REPLACEMENT FROM 7075T6-C#.090' LOT#SDR SWAA2022092244533None · corrodedCORROSION ON PASSENGER CABIN FLOOR BEAM UPPER SURFACE AT STA 727A+18; LBL 23; WL 208. / [01] REMOVED CORRODED FILLER FOR LONGITUDINAL BEAM BS 727A+18; LBL 23; WL 208 PER SRM 51-40-02; FABRICATED REPLACEMENT FROM 7075T6-C#.090' LOT# 1482311 AS SHOWN ON EA 1-757SDR SWAA2022092244534None · corrodedCORROSION ON PASSENGER CABIN FLOOR BEAM UPPER SURFACE AT STA 727A+17 TO 727A+19; RBL 44.5; WL 208. / [01] REMOVED CORRODED FILLER FOR LONGITUDINAL BEAM BS 727A+17 TO BS 727A+19; RBL 44.5; WL 208 PER SRM 51-40-02; FABRICATED REPLACEMENT FROM 7075T6-C#.090' LOT#SDR SWAA2022092744733Beam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BS986.5 WL208.1 AND BETWEEN LBL28 TO LBL43 AT AFT GALLEY AREA 2022-441373 / [01] TOOL P/N: 35DL; S/N: 091419910; CAL DUE: 26 -JAN-23.;[02] TOOL USED: EDDY CURRENT FLAW DETECTOR P/N: NORTEC 600D; S/N: 210138003; DUE DATE: SDR SWAA2022092744729None · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BS986.5 AT RBL43 AND WL208.1 AT AFT GALLEY AREA 2022-441372 / [01] EQUIPMENT P/N 38DLPLUS; S/N 120398603; DUE DATE 18-OCT-22 WAS USED;[02] TOOL USED: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; DUE DATE: 03SDR SWAA2022092777342Beam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BS312 AT LBL13 TO LBL15 AND WL208.1 AT FWD GALLEY AREA 2022-441307 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23;[02] TOOL USED CALIPER PN: 500-197-30; SN: 15120589; DUE DATE: 28-NOV-2SDR SWAA2022092744369Beam · corrodedCORROSION FLOOR STRUCTURE BEAM LOCATED BS328 AT RBL39 TO RBL42 AND WL208.1 AT FWD GALLEY AREA 2022-441309 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23;[02] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 1120SDR AALA202209206731Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CABIN FLOOR BEAM AT FR 16 AND +Y1292. REPLACED FLOOR BEAM PER SRM 51-72-11.