JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2022051301220Floorbeam · corrodedCORROSION ON FLOORBEAM STA 377 AT L1 DOOR (MARKED)SDR SWAA2022060806417Floorbeam · corrodedCORROSION ON PASSENGER CABIN FLOOR BEAM AT BS 987 LBL43.VERIFIED APPLICABILITY OF SRM 53-70-51-01-1 FOR IDENTIFICATION AND SRM 53-70-51-1A-1 FOR ALLOWABLE LIMIT; REMOVED CORROSION FROM PASSENGER CABIN FLOOR BEAM BS 987 LBL43 WL 208.5 IN AREA OF 1.3' X 0.9' X 0SDR R61A2022052200362Panel Support · corrodedWHILE AC WAS IN FOR HVY CK FOUND FUSELAGE 3 FLOOR STRUCTURE GALLEY SUPPORT FITTING CORRODED BTWN FR 87-88, RBL 22.AAR MX REPLACED PANEL SUPPORT PN 170-86131-001 IAW SRM 51-43-01. AC REMAINS IN YQG FOR COMPLETION.SDR CALA2022051101203Intercostal · corroded(B757-53-3-0479) GALLEY 1B FLOOR STRUCTURE INTERCOSTAL STATION 400 INBOARD HAS CORROSION. DOT: F542. TRANSCRIBED FROM HAECO GSO NR 9286842.SDR CALA2022051101202Floor Support · corroded(B757-53-3-0479) GALLEY 1B FLOOR STRUCTURE INTERCOSTAL BETWEEN STATION 377- 400 HAS CORROSION. DOT:F541. TRANSCRIBED FROM HAECO GSO NR 9286841.SDR R61A2022052200361Panel Support · corrodedWHILE AC WAS IN FOR HVY CK FOUND FUSELAGE 3 FLOOR STRUCTURE CORROSION FOUND ON RH PANEL SUPPORT BTWN FR 88-90. AAR MX REPLACED PANEL SUPPORT PN 170-86181-005 IAW SRM 51-42-01,51-43-01 AC REMAINS IN YQG FOR COMPLETION.SDR R61A2022052200360Shear Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND FUSELAGE 3 FLOOR STRUCTURE CORROSION FOUND ON RH SHEAR PANEL PN 170-91919-001 BTWN FR 87-88 AC REMAINS IN YQG FOR COMPLETION.SDR R61A2022052200359Seat Track · corrodedWHILE AC WAS IN FOR HVY CK FOUND PAX FLOOR STRUCTURE CORROSION FOUND ON LH IB SEAT TRACK CROWN TEETH BTWN FR19-20. AAR MX REPLACED SEAT TRACK PN 170-03264-001 IAW SRM 51-41-02, 51-43-03. AC REMAINS IN YQG FOR COMPLETION.SDR R61A2022051200345Floor Support · corrodedLEVEL 2 CORROSION WAS FOUND AT CF 3 RH FLOOR SUPPORT BETWEEN FR86 TO FR90. SUPPORT WAS REPLACED IAW SRM 51-43-03SDR SWAA2022061403530Floorbeam · corroded*CORROSION* FWD CABIN STA 328 RBL 42.5 TO RBL 56 WL 208.1 FLOOR SUPPORT BEAM HAS CORROSION AS MARKED. 124-023 / [01] REMOVED CORROSION AT FWD CABIN STA 328 RBL 42.5 TO RBL 56 WL 208.1 FLOOR SUPPORT IAW SRM 51-10-02-0G-0 REMAINING MATERIAL 0.108' FOUND OUT OF LSDR SWAA2022061403524Support Beam · corroded*CORROSION* FWD CABIN STA 312 LBL 12 TO LBL 48 WL 208.1 FLOOR SUPPORT BEAM HAS CORROSION AROUND FASTENER HOLES AS MARKED. 124-018 / [01] REMOVED CORROSION AT FWD CABIN STA 312 LBL 12 TO LBL 48 WL 208.1 FLOOR SUPPORT BEAM IAW SRM 51-10-02-0G-0;[02] VERIFIED STESDR SWAA2022061403513Floorbeam · corrodedFLOORBEAM STA 986.5;BETWEEN LBL40 TO LBL47 HAS CORROSION. / REMOVED EXFOLIATED UPPER CHORD OF THE FLOORBEAM AT STA 986.5 FROM BL 0 TO RBL 50 WL 208.1 REF B737-700 SRM 51-40-02-0G-0.FABRICATED LOCATED AND DRILLED NEW UPPER TEE CHORD FROM LBL 50 TO RBL 50 STA. 9SDR V0XD20220525001None · noneFLOOR BOARD CROSS BEAM AT FR 20 UNDER FLOOR BOARD 231FF IS CORRODED. CORRECTIVE ACTION: REMOVED AND REPLACED FLOOR BEAM (P/N: 145-20600-603) IAW EMB 135/145 SRM 51-40-02.SDR R61A2022051200343Shear Panel · corrodedLEVEL 2 CORROSION FOUND AT CF 3 FLOOR RH SHEAR PANEL BETWEEN FR87 AND FR88. SHEAR PANEL WAS REPLACED IAW SRM 51-42-01SDR R61A2022051200342Shear Panel · corrodedLEVEL 2 CORROSION FOUND AT CF 3 FLOOR LH SHEAR PANEL BETWEEN FR87 AND FR88. SHEAR PANEL WAS REPLACED IAW SRM 51-42-01SDR SWAA2022060902344Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER SURFACE AT STA 986.5; WL 208; BUTT LINES: RBL 41.5-45; RBL 35; RBL 21; LBL 30; LBL 35; LBL 42; LBL 44. / ALL FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1 CUT AND REMOVED UPPER FLANGE OF BS 986.5 FLOOR BEAM PER SRM 53-70-51-2R-4;SDR ASAA2022050138517Floorbeam · corrodedAFT WET AREA: STA. 986 FLOORBEAM HAS CORROSION AT FASTENER HOLES. MARKED IN RED. GROUNDED - YES. REMOVED CORROSION AND EVALED. ORIG T .150", REMOVED .009", REMAIN T .141" FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1 FABRICATED NEW REPAIR PARTS (1 ESDR ASAA2022050138384Floorbeam · corrodedSTA 947.5 FLOORBEAM, BUTTLINE 45R HAS CORROSION. GROUNDED - YES. EVALUATED CORROSION.ORIGINAL T .180"T REMOVED .028"T REMAIN .152"FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1.REMOVED CORRODED SECTION AND SURROUNDING STRUCTURE IAW B737-800 SRM 51-40SDR IXXA2022050101Support Beam · corrodedCORROSION ON THE LOWER AND UPPER SURFACES OF THE WING LOCK SUPPORT TRAY STA 1219 FROM LBL-6 - RBL- 20SDR AALA202207018451Flange · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON UPPER FLANGE OF STA 987 FLOOR BEAM AROUND ONE FASTENER HOLE. LOCATED AT STA 987 AND LEFT BUTT LINE 45. INSTALLED DOUBLER REPAIR PER SRM 53-70-51-2R.SDR AALA202205179957Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION AROUND FASTENER HOLES IN PASSENGER CABIN FLOOR BEAM, LOCATED AT BS 986 AND BETWEEN RBL 33 TO RBL 43. REPAIRED PER SRM 53-70-51-2R-6 ALTERNATIVE 3 AND EA 336053SDR AALA202205179269Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR INTERCOSTAL CRACKED LOCATED BETWEEN STA 277 - 294, STR L17R AND RIGHT BUTT LINE 4. REMOVED AND REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR AALA202205176851Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR INTERCOSTAL CRACKED BETWEEN STA 328-344, STR 17L, AND LEFT BUTT LINE 43. REMOVED AND REPLACED INTERCOSTAL PER AARD 51-00-05-1.SDR UIEA2022042800417Strap · noneUPPER DECK FLOOR BEAM MODIFY TOP KIT (KIT NO: 015U16B-1) WITHOUT ONE OF THE STRAP(<P>1) ACCOMPLISHED JOB IAW EI NO: T2022A53M-1063 REV 1 2) CONDITION CHECK NORMAL AND JOB COMPLETED </P>)SDR SWAA2022060300980Floorbeam · crackedCRACK FLOOR BEAM BS 294.5 AT RBL 54 FWD GALLEY AND LAV 2022-223399 / [01] TOOL USED: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; DUE DATE: 03-DEC-22;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23SDR REXA2022063001417Angle · corrodedFLOOR SUPPORT ANGLE AT FS280.00 HAS AREA OF CORROSION 3.0" X 3.5" X .020" DEEP REMOVE AND REPLACE ANGLE.SDR SWAA2022053100101Floorbeam · corrodedFLOOR SUPPORT BEAM HAS SPOT OF CORROSION IN FRONT TO L2 DOOR STA 986.5 / REMOVED CORROSION AT FLOOR SUPPORT BEAM IN FRONT TO L2 DOOR STA 986.5 LBL45 IAW B737-700 SRM 51-10-02-0G-0.MATERIAL REMAINING 0.082 FOUND OUT OF LIMITS IAW B737-700 SRM 53-70-51-1A-1 FIG.SDR SWAA2022053100100Floorbeam · corrodedFLOOR SUPPORT BEAM HAS SPOT OF CORROSION IN FRONT TO R2 DOOR STA 986.5. / REMOVED CORROSION AT FLOOR SUPPORT BEAM IN FRONT TO R2 DOOR STA 986.5 RBL45 IAW B737-700 SRM 51-10-02-0G-0. MATERIAL REMAINING 0.082 FOUND OUT OF LIMITS IAW B737-700 SRM 53-70-51-1A-1 FISDR CALA2022042901098Beam · corrodedB757-53-3-0479 GALLEY 1B FLOOR STRUCTURE T-CAP STATION 365 INBOA RD HAS APPROX 2O" CORROSION, TRANSCRIBED FROM HAECO GSO NR 92868 39 REMOVED CORROSION ON T-CAP AT STA 365. ORIGINAL MAT THICKNESS IS 53-00-51-2R-10 REPAIR 10 FIG 201 DETAIL I AND II. RESTORED FINSDR SROM042722None · corrodedLH AFT SEAT FLOOR RAIL P/N: 85338210-111 CORRODED AT AFT TIE DOWN RING IN AFT BAGGAGE COMPARTMENT. MEASURED AT 0.060" BEFORE BLENDING AND LIMIT IS 0.040" PER SRM 53-40-49. NEW REPLACEMENT FLOOR RAIL WILL BE INSTALLED.SDR CALA2022042701080Floorbeam · corrodedB757-53-3-0559 FLOOR BEAM AT STA 720RH - FROM RBL 24.75 TO RBL 5 8.22 T-CAP MULTIPLE AREAS OF CORROSION, TRANSCRIBED FROM HAECO GSO NR 9287021 REMOVED AND REPLACED FLOOR BEAM UPPER STRAP PN 95-030-3 IAW B757 -200 SRM 51-40-02 AND TRAMCO DWG 95-030 REV A. HAECSDR IXXA2022042601Floorbeam · corrodedFLOOR SUPPORT FS 1540 CORROSION LBL33-RBL33SDR SWAA2022053197678Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS312 AT LBL16 AND WL208.1 AT FWD GALLEY AREA 2022-207236 / [01] TOOL EDDY CURRENT USED P/N: NORTEC 600D S/N: 60009161631 AND DUE DATE: 03-DEC-22.;[02] REPAIRED FLOOR BEAM LOCATED BS312 AT LBL16 AND WL208.1 AT FWD GALLEY AREA IAW BSDR SWAA2022053197671Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS294.5 AT RBL9 TO RBL13 AND WL208.1 AT FWD GALLEY AREA 2022-207229 REPAIRED FLOOR BEAM LOC. BS294.5 AT RBL9 TO RBL13 AND WL208.1 AT FWD GALLEY AREA; IAW SRM 53-10-51-2R-16 THIS REPAIR IS CATEGORY A. REPAIRED FLOOR BEAM LOC. BS294.SDR SWAA2022053197670Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS328 AT RBL42 AND WL208.1 AT FWD GALLEY AREA 2022-207223 ; REPAIRED FLOOR BEAM LOCATED BS328 AT LBL 6 TO RBL 60 AND WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-7 REPAIR 7 ALTERNATIVE 2 THIS REPAIR IS CATEGORY A.THIS RESDR SWAA2022053197669Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS328 AT RBL19 TO RBL22 AND WL208.1 AT FWD GALLEY AREA 2022-207225. REPAIRED FLOOR BEAM LOCATED BS328 AT LBL6 TO RBL60 AND WL208.1 AT FWD GALLEY AREA IAW B737-700 SRM 53-10-51-2R-7 REPAIR 7 ALTERNATIVE 2. THIS REPAIR IS CATEGORY A.SDR SWAA2022053197664Floorbeam · corrodedCORROSION ON FLOOR BEAM 986.5 LBL 44 AND WL 208.1 AFT GALLEY AREA 2022-207220 / [04] REPAIRED FLOOR BEAM 986.5 LBL 55.8 BTW LBL 64 AND WL 208.1 AFT GALLEY AREA I.A.W B737-700 SRM 53-70-51-2R-6 REPAIR 6 TABLE 204 FIGURE: 205. THIS REPAIR IS CATEGORY AND NOT REQSDR SWAA2022053197663Floorbeam · corrodedCORROSION ON FLOOR BEAM 986.5 BTW RBL 39 TO RBL 44 AND WL 208.1 AFT GALLEY AREA 2022-207216 / [01] TOOL USED PN:35DL; SN:091419910; DUE DATE:26-JAN-23.;[02] ET TOOL USED: PN: PHASEC 3D; SN: 587435 /03; DUE DATE: 22 -DEC -22;[03] REPAIRED FLOOR BEAM 986.5 BTW RSDR SWAA2022053197662Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS344 AT LBL9 AND WL208.1 AT FWD GALLEY AREA 2022-207215. [05] REPAIRED FLOOR BEAM BTW BS 328 TO BS 360 LBL 11.10 WL208.1 AT FWD GALLEY AREA I.A.W B737-700 SRM 53-10-51-2R-9 REPAIR 9 REPAIR IS CATEGORY: A DOES NOT REQUIRE INSPECTIOSDR SWAA2022053197661Floorbeam · corrodedCORROSION ON FLOOR BEAM 986.5 RBL 5 AND WL 208. AFT GALLEY AREA 2022-207214 / [01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN:45MG; SN: 130064101; DUE DATE: 11-MAY-22;[02] EDDY CURRENT EQUIPMENT P/N: NORTEC500D; S/N: N500X12101V022235; DUE DATE: 03-JUN-22.;[03]SDR FDEA202204251329Floorbeam · corrodedCABIN BETWEEN STA 1200 FOUND CORROSION ON BEAM BETWEEN RBL 3-RBL 19 WORK ACCOMPLISHED IN ACCORDANCE WITH FEDEX E.A # F-5310-T0368550: SECTION 45, FLOOR BEAM ASSY, STA 1200, UPPER CHORD, RBL 3 TO RBL 19, CORROSION, REPAIR. MAJOR REPAIRSDR AALA202205104052Floorboard · crackedAIRCRAFT IN BASE MAINTENANCE: Z ANGLE FLOOR BOARD SUPPORT HAS DAMAGE AT UPPER FLANGE AT STA 990 RIGHT BUTT LINE 34-47. REPLACED Z ANGLE FLOORBOARD SUPPORT PER AARD 51-00-05-1.SDR SWAA2022052397184Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED ON BS 294.5 LBL 10 AND WL 208.1 FWD GALLEY AREA 2022-211490 / [01] TOOL USED PN NORTEC 600D; SN. 60009161631; DUE DATE: 03-DEC-22;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 02-FEB-23; SDR SWAA2022051997197Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED ON BS 986.5 LBL 43 AND WL 208.1 AFT GALLEY AREA 2022-211514 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23;[02] TOOL EDDY CURRENT USED P/N: NORTEC 600 S/N: 210136503 AND DUE DATE: 11-APR-23.;[SDR SWAA2022051997202Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED ON BS 986.5 RBL 43 WL 208.1 AFT GALLEY AREA 2022-211517 / [01] TOOL USED ULTRASONIC EQUIPMENT PN: 35DL; SN: 091419910; DUE DATE: 26 JAN 23;[02] TOOL EDDY CURRENT USED P/N: NORTEC 600 S/N: 210136503 AND DUE DATE: 11-APR-23.;[03] SDR SWAA2022051997189Floorbeam · corrodedCORROSION ON FLOOR BEAM LOCATED ON BS 344 AND BTW RBL 1 TO LBL 12 AND WL 208.1 FWD GALLEY AREA 2022-211500 / [01] ULTRASONIC EQUIPMENT USED: P/N:45MG; S/N:130066401; DUE DATE: 17-JUN-22;[02] TOOL USED: ET EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; CAL DUE DSDR CALA2022042501059Frame · misrepairedSUPPORT TASK, MAIN CABIN STA 760 L/H FUSELAGE FRAME AT FLOORBEAM HAS A DRILL START, TRANSCRIBED FROM HAECO GSO NRC 9285440 REPAIRED DRILL START ON MAIN CABIN STA 760 L/H FUSELAGE FRAME AT FLOORBEAM IAW UAL ECRA 5332-01026 AND HAECO REO-G23725, HAECO G SO MECH SDR SWAA2022051796878Floorbeam · corrodedCORROSION ON 986 FLOORBEAM; FWD UPPER FLANGE; LBL 43; WL 208. / [01] VERIFIED APPLICABILITY PER SRM 53-70-51-1A-1;[02] REMOVED CORROSION ON BS986 FWD FLANGE LBL43 WL208 1''X1'' AREA I.A.W SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR 4.H.(2)(B) FIG 104/ALLOWABLE DASDR KCSA202204211050Floorbeam · corrodedSTA 420 BL 0 TO RBL 45 HAS EVIDENCE OF CORROSION ON UPPER SURFACE OF UPPER DECK FLOOR BEAMSDR SWAA2022051796305Floorbeam · corrodedCORROSION ON BS 947 FLOOR BEAM LBL 27 WL 208. / [01] VERIFIED APPLICABILITY PER SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR.4.H(2)(B) FIG.C;13] FABRICATED REPAIR PARTS ITEM(1) T-CHORD FROM BAC1505-101045 7075T6 LOT #5098135-1;ITEM(2) ANGLE FROM 7075-TO 0.100' LOT
Back to JASC 5315