What was found
*CORROSION* FWD CABIN STA 312 LBL 12 TO LBL 48 WL 208.1 FLOOR SUPPORT BEAM HAS CORROSION AROUND FASTENER HOLES AS MARKED. 124-018 / [01] REMOVED CORROSION AT FWD CABIN STA 312 LBL 12 TO LBL 48 WL 208.1 FLOOR SUPPORT BEAM IAW SRM 51-10-02-0G-0;[02] VERIFIED STEP 1<BR>ACCOMPLISHED A VISUAL INSPECTION WITH A 10 POWER MAGNIFING GLASS OF THE REWORKED AREA NO CORROSION OR CRACKS NOTED. REF SRM 51-10-02-0G-0 STEP 15. A. (6)(A);[24] FABRICATED REPAIR ANGLE (4 EACH) FOR STA 312 FLOOR BEAM. MATERIAL USED: 7075-0; 0.080' (PO#1740779) IAW SRM 53-10-51-2R-17.;[25] HEAT TREATED REPAIR ANGLES (4 EACH) FROM 7075-0 TO 7075-T62 IAW BAC5602 AND SRM 53-10-51-2R-17.;[26] (AMENDING STEP 25) HEAT TREATED REPAIR ANGLES (4 EACH) FROM 7075-0 TO 7075-T62 IAW BAC5602; AAR OP 84-REV 7; AND SRM 53-10-51-2R-17.;[27] VERIFIED STEPS #23; #24; #