JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2021071071498Floorbeam · crackedINSPECTION TYPE:2CFORWARD CARGO COMPARTMENT FLOOR BEAM CRACK AT STA.Y= 6-70,X= -57.5 AND Z= -98.REPAIRED CRACKED FWD CARGO COMPT FLOOR BEAM IAW SRM 53-40-51,REPAIR 1,FIG 202,REV 67SDR MASA20210706265Floorbeam · crackedCRACK ON LONGITUDUNAL FLOOR BEAM 12RBL IN STA. FS= 279 AT COCKPIT|LONGITUDUNAL FLOOR BEAM 12RBL IN STA. FS= 279 WAS REPAIRED PER EA 20-2021-140 REV. IRSDR JR2R20210629851Floorbeam · corrodedFLOOR BEAM AT LBL12 CORRODED AT THE TOP AND BOTTOM SIDE JUST AFT OF BEAM 18SDR AALA202107133622Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION OF FLOOR BEAM AT STA 986 AND LBL 46, MEASURING L=1.0 IN, W=0.075 IN, D=0.056 IN. ACCOMPLISHED PERMANENT REINFORCING REPAIR WITH NESTED ANGLES IAW SRM 53-00-51-2R-1 AND EA 328862.SDR CALA2021063000992Floorbeam · corroded(A3NB-53-3-6185) MAIN CABIN, AFT CABIN FR 66 BEAM BETWEEN Y254 & Y254 HAS CORROSION. DOT 102-133. FLOOR BEAM WAS ELEVATED AND FOUND OUT OF ALLOWABLE DAMAGE IAW A3 19 SRM 53-00-14-283, NEW FLOOR BEAM WAS FABRICATED TO MAT. P/NDA N338C06 BATCH#1837634 IAW SRM51-SDR SWAA2021071387751Floorbeam · corrodedAFT CARGO FLOOR BEAM STRUCTURE FOR; R/H TRANSITION ANGLE JUST FWD OF DOOR; HAS LIGHT SURFACE CORROSION AT BS 767+5. ; / [01] REMOVED CORROSION PER SRM 53-00-53-1A-2 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.; [02] BACK DRILLED FASTENER HOLES IN NEW ANGLESDR DALA2021062703472Floorbeam · corrodedSHIP 651 DURING INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON FLOOR BEAM (PREVIOUS REPAIR) AT PASSENGER COMPARTMENT STA. 377, BTW LBL 35 TO LBL 52. REPAIRED PER ERA 473175-14. (LP 1854423)SDR JR2R2021062678879Floorbeam · corrodedL/H FLOOR BEAM AT FR 17 LBL 10 CORRODED OUT OF LIMITS. REPAIRED IAW ETD 2021-170-019785.SDR JR2R2021062678763Floorbeam · corrodedLBL 11FLOOR BEAM AT FRAME 19 IS CORRODED OUT OF LIMITS. REPAIRED IAW E175 SRM 53-10-10 REPAIR 01.SDR SWIA2021081960384Floorbeam · corroded* F/S 280 CROSSBEAM AT FLIGHT DECK ENTRANCE HAS CORROSION ( MARKED ) (C-CHECK RO 8/18/2021) REMOVED FLOOR SUPPORT ANGLE AT FS280 AND REPLACED WITH A SERVICEABLE UNIT COMPLIED WITH TASK CARD 51-900-1002-SKY REF. CRJ700 SRM 51-42-06-001-001-A01 & SRM 51-4SDR CALA2021062800976Floorbeam · corroded(A3NB-53-3-6038) MAIN CABIN FLOOR STRUCTURE AT Y254 HAS CORROSIO N AT CC16 P/N P/N D53112817004. DOT 102-120 () FLOOR BEAM FOUND OUT OF ALLOWABLE DAMAGE LIMITS IAW A319 SRM 53- 11-14-283-005 AND REPLACED IAW SRM 51-72-11-911.SDR CALA2021062800975Floorbeam · corrodedA3NB-25-3-6221 DOT 42-025 AFT CABIN FLOOR SUPPORT BEAM CORRODED FR66 Y765 LAV MOUNT AREA () REMOVED AND REPLACED FOR A NEW FLOORBEAM P/N D5347204000200 IAW A319 SRM 51-42-11.SDR MASA20210706267Floorbeam · crackedCRACK ON ANGLE P/N CC670-33199-4 . ANGLE WAS REPAIRED PER CRJ 900 SRM 51-71-59-001-001-A01.SDR CALA2021062500959Floorbeam · corroded(A3NB-53-3-6038) MAIN CABIN FLOOR STRUCTURE Y1292 HAS CORROSION AND SCRATCHES AROUND FASTGENER HOLES C-12-16 P/N D5311281520201. DOT 102-116 () REMOVED AND REPLACED WITH NEW FLOOR BEAM P/N=D5311281300251 BATC H:0003786788 IAW A319 SRM 51-42-11.SDR SWAA2021071287148Floorbeam · crackedCRACK AT FLOOR BEAM FASTENER HOLE BS 294.5 RBL 52.5 WL 208 ; / [01] REMOVED CRACK BY 1' X 1' TRIM OUT AT BS 294.5 RBL 52.5 WL208 PER SRM 51-10-02-0G-0; [02] VERIFIED REMOVED CRACK BY 1' X 1' TRIM OUT AT BS 294.5 RBL 52.5 WL208 PER SRM 51-10-02-0G-0; [03] REQUESDR IPXA2021070671320Floorbeam · corrodedINSPECTION TYPE:2CFWD MAIN CABIN LAV FLOOR SUPPORT HAS HEAVY CORROSION AT STA Y=421.578 BETWEEN X=-65 & X=-81.REMOVED,FABRICATED AND REPLACED CORRODED FLOOR SUPPORT IAW SRM 51-31-01 (MINOR).SDR DALA2021062803492Floorbeam · corrodedSHIP 3161 - CORROSION FLOOR BEAM -Y189 AT LEVEL FR20 IN PASSENGER CABIN . CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y189 AND FASTENERS LOC. AT LEVEL FR.20 IN PASSENGER CABIN AS PER A319 SRM 51-72 AND DWG. (1850756)SDR CALA2021062500949Floorbeam · corrodedA3NB-25-3-6221 DOT 42-027 AFT CABIN FLOOR SUPPORT BEAM CORRODED FR66 Y254 AREA () REMOVED OLD FLOOR BEAM (SUPPORT) AND REPLACED WITH NEW FLOOR BEA M P/N:D534728802000 BTCH:0001820499 IAW A319 SRM 51-42-11. ATTAC CHED FORM: 44-0008. ACCOMPLISHED BY V934700 AT BSDR CALA2021062500948Floorbeam · corrodedA3NB-53-3-6222 AFT MAIN CABIN FLOOR SUPPORT Y254 HAS CORROSION A T FR68. (DOT 38-46) () BEAM WAS FOUND OUT OF ALLOWABLE DAMAGE IAW 53-00-14-283 L=3.0 W= 3.0" D=0.070" (EXCLUDED AREA) AND FLOOR BEAM WAS REPLACED IAW SR M 51-72-11-911. PN=D534721962000 BATCH=000SDR SWAA2021080487204Floorbeam · corrodedCORROSION FOUND ON FLIGHT DECK FLOOR UPPER FLANGE OF BS 259.5; LBL 11 - RBL 11; WL 208 ; / [01] REMOVED FASTENER ON DAMAGED AREA FOR ACCESS I.A.W SRM 51-40-02-0G-0; [02] NO APPLICABILITY ENTRIES FOUND ON SRM <BR>DAMAGE TO BE REMOVE PER SRM 51-10-02-0G-0; [03] SDR SWAA2021080487203Floorbeam · corrodedCORROSION FOUND ON LATERAL BEAM UPPER FLANGE AT BS 270; LBL 11 - RBL 11; WL 208 ; / REMOVED FASTENER ON DAMAGED AREA FOR ACCESS I.A.W SRM 51-40-02-0G-0; VERIFIED APPLICABILITY PER SRM 53-10-51-1A-1 PAR 4.C(2)(A) FIGURE 105/ALLOWABLE DAMAGE 1 DETAIL E; [03] REMSDR SWAA2021080486984Floorbeam · crackedMAIN CABIN FLOOR SUPPORT BREAK CRACKED AT STA 540 RBL1 ; / [01] REMOVED PANEL 231UF FOR ACCESS TO MAIN CABIN FLOOR SUPPORT BREAK ASSY IAW AMM 53-21-00-000-801.; [02] REMOVED BOTH MAIN CABIN FLOOR SUPPORT BREAK ASSY AT STA 540 RBL1 IAW SRM 51-40-02-0G-0.; [03] SDR ASAA2021062235293Floorbeam · corrodedAFT PASSENGER WET AREA HAS PITTING CORROSION ON STRUCTURE BEAM STA 947 UNDER LAV E FLOOR PANEL CIRCLE IN RED AND STREAMER ATTACHED.DOT A763. GROUNDED - YES. REMOVED CORROSION FROM THE UPPER SURFACE OF THE TRANSVERSE FLOOR BEAM IN THE AFT WET AREA IN THE MAIN CSDR ASAA2021062135410Floorbeam · corrodedFLOOR BEAM AT FS 986.5 HAS AREAS OF CORROSION FROM LBL45-RBL45. GROUNDED - YES. REPAIRED FLOOR BEAM AT FS 986.5 IAW B737-900 SRM 53-70-51-2R-4 BY REMOVING AND REPLACING CORRODED REPAIR PARTS W- 3 O- .150 R- .110 L- 18 D-.040.SDR YENA2021062500404Floorbeam · corrodedDURING HMV, CORROSION: FLOOR STRUCTURE FR84 @ Y=230RH ; REF TOMX NR 00391: ORIGINAL DOUBLE REPAIR WAS REMOVED & REPLACED IAW EMBRAER SRM 51-43-03 ITEM 6 FIG 2, 51-43-04 ITEM 5 FIG 2 AND 53-23-10 REPAIR 54 ITEM 6 STEP J-M.SDR YENA2021062500401Floorbeam · corrodedDURING HMV, CORROSION: FLOOR STRUCTURE FR84 & Y1200LH ; REF TOMX NR 00394: R & R PANEL IAW EMB 190 SRM 51-41-02 PAR 6 AND 51-41-01 PAR. 06.SDR DALA2021062303393Floorbeam · corrodedSHIP 663 CORROSION ON FLOOR BEAM STA 377.7 FROM LBL 55 TO LBL 62 AT PASSENGER CABIN FLOOR STRUCTURE (IN REF NRC: 00883). CORRECTIVE ACTION: SUMMARY OF NRC 00887. FLOOR BEAM STA 377.7 FROM LBL 55 TO LBL 62 AT PASSENGER CABIN FLOOR STRUCTURE WAS REPAIRED PER B 7SDR DALA2021062103355Floorbeam · corrodedSHIP 651 CORROSION ON FLOOR BEAM AT PASSENGER COMPARTMENT, STA. 345, RBL35. CORRECTIVE ACTION: SUMMARY OF NRC 00469: CORROSION LEVEL 2. FLOOR BEAM AT PASSENGER COMPARTMENT, STA. 345, RBL 35 WAS REPAIRED PER B757-200 SRM. (1846229)SDR FDEA202106191572Floorbeam · corrodedLH NOSE TUNNEL, MAIN CABIN FLOOR BEAM, FLOOR BOARD ATTACH FASTENER HOLE IS CORRODED AT STA 377.7 AT APPROX LBL24 ACCOMPLISHED FEDEX EA # F-5310-TO333967-P2 FUSELAGE - MAINFRAME - EXFOLIATION CORROSION ON FLOOR BEAM AT STA 377.7, LBL 24.75 - 58.22SDR SWAA2021071485552Floorbeam · corrodedCORROSION AT AFT CARGO BAY FLOOR SUPPORT SPLICE BS 773 LBL 20-RBL 19 WL 157 ; / [01] CORROSION FOUND ON AFT CARGO BAY FLOOR SUPPORT SPLICE BS773 LBL20-RBL19 WL157 FOUND TO BE OUT LIMITS DUE TO NO LIMITS ON SRM PARTS WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-1SDR SWAA2021071485548Floorbeam · corrodedCORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 LBL8 TO RBL15 WL180. ; / [01] NO ALLOWABLE DAMAGE FOUND AT SRM FOR THIS PART; PART REQUIRED TO BE REMOVED AND REPLACE IAW SRM 51-10-02-0G-0 PAR 9.; [02] VERIFIED; [03] REMOVED AFT BULKHEADSDR SWAA2021071985218Floorbeam · crackedCRACKED BREAK PANEL BS 540 LBL 1 WL 208. ; / [01] REMOVED CRACKED BREAK PANEL ASSY BS 540; BL 0 - LBL 25; WL 208 PER SRM 51-40-02-0G-0.; [02] LOCATED AND DRILLED NEW BREAK PANEL ASSY BS 540; BL 0 - LBL 25; WL 208 PER SRM 51-40-05-0G-0. OK TO INSTALL NEW BREAK SDR SWAA2021071985221Floorbeam · crackedCRACKED BREAK PANEL BS 540 RBL 1 WL 208. ; / [01] REMOVED CRACKED BREAK PANEL ASSY BS 540; BL 0 - RBL 25; WL 208 PER SRM 51-40-02-0G-0.; [02] LOCATED AND DRILLED NEW BREAK PANEL ASSY BS 540; BL 0 - RBL 25; WL 208 PER SRM 51-40-05-0G-0. OK TO INSTALL NEW BREAK SDR FDEA202106161552Floorbeam · crackedCENTER CARGO - FLOOR BEAM STATION 1741 CENTER SECTION FOUND CRACKED. CENTER CARGO FLOOR BEAM STATION 1741 CENTER SECTION CRACKED CARRIED OUT REPAIR AS PER EA 1-5321-T0362363 PART 1. TITLE: FUSELAGE - CARGO COMP FLOORS - LOWER CENTER CARGO FLOOR BEAM REPAIRSDR SWIA2021081860342Floorbeam · corroded* UNDER COCKPIT FLOOR FS250.00 IS CORRODED APPROX. SRTG 26LH AND 26RH. FLAGGED (C-CHECK RO 8/16/2021) REPLACED THE LOWER ATTACH FLANGE FRAME BETWEEN STR 25L-25R PER REO 670-53-11-1707 REV -A DATED 2021-07-30, DWG CC670-34030 REV -B, CRJ 700 SRM 51-42-0SDR SWAA2021072284718Floorbeam · crackedB.S. 328 FLOOR BEAM IS CRACKED AT R.B.L. 24; W.L. 208.1; COMING OUT OF FASTENER HOLE. ; / [01] EVALUATED CRACK L=0.300'' ON FLOOR BEAM BS 328 RBL 24 WL 208.1 COMING OUT OF FASTENER HOLE AND FOUNT TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1 PART 4C; FLOOR BEAM RESDR REXA2021071300495Floorbeam · corrodedFS 280.00 TRANSVERSE FLOORBEAM, COCKPIT FLOOR SUPPORT J ANGLE CORRODED. REMOVED J ASSY ANGLE AND REPLACED WITH NEW J ASSY ANGLE P/N: CC670-340095-1 IAW CRJ 900 SRM 51-42-21-001-001-A01, 51-42-06-001-001-001-A01, 51-25-16-001-001-A01, 51-21-11-001-001-A01.SDR R61A2021063000516Floorbeam · corrodedWHILE AC WAS IN FOR HVY CK CORROSION FOUND ON CENTER FUSE 3 AFT CARGO FLOOR SUPPORT AT FR 77 AND STR 29L-29L. REPLACED FLOOR SUPPORT PN 170-66350-002 IAW SRM 51-41-01, 51-41-02. SEE AAR NRC# 4500917-1000-0105 FOR DETAILS OF WORK PERFORMED. AC REMAINS IN YQG FOSDR R61A2021062900518Shear Angle · corrodedWHILE AC WAS IN FOR HVY CKCORROSION FOUND ON CENTER FUSELAGE 3 AFT CARGO FLOOR SUPPORT SHEAR CLIP AT FR 81 AND STR 29R-29L. REPLACED SUPPORT PN 170-66354-002 IAW SRM 51-41-01. SEE AAR NRC# 4500917-1000-0102 FOR DETAILS OF WORK PERFORMED. AC REMAINS IN YQG FOR SDR R61A2021062900515Floorbeam · corrodedWHILE AC WAS IN FOR HVY CK CORROSION FOUND ON CENTER FUSELAGE 3 AFT CARGO FLOOR SUPPORT AT FR 79 AND STR 29L-29R. REPLACED SUPPORT PN 170-65912-001 IAW SRM 51-41-01, SEE AAR NRC# 4500917-1000-0104. AC REMAINS IN YQG FOR COMPLETION.SDR R61A20210629514Floorbeam · corrodedWHILE AC WAS IN FOR HVY CK FOUND CORROSION FOUND ON CENTER FUSELAGE 3 AFT CARGO FLOOR SUPPORT AT FR 80 AND STR 29R-29L. REPLACED SUPPORT PN 170-66353-001 IAW SRM 51-41-01 SEE AAR NRC# 4500917-1000-0103. FOR DETAILS OF WORK PERFORMED. AC REMAINS IN YQG FOR COMPSDR AALA202107136121Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON FLOOR BEAM AT STA 987, LEFT BUTT LINE 45. INSTALLED REPAIR PER EA NUMBER 328558 AND SRM 53-70-51-2R-6.SDR AALA202106302365Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM LOCATED AT STA 987 AND LBL 45. REPAIRED FLOOR BEAM PER EA 328558 SRM 53-70-51-2R-6.SDR REXA2021062900478Floorbeam · corrodedFS 280 BEAM CORRODED AT RBL 9 WL 72. R/R UNSERVICEABLE 280 BEAM WITH SERVICEABLE BEAM @ RBL 9.0 WL 72 IAW CRJ 900 SRM 51-40-11-001-001(A01), 51-42-06-001-001(A01), 51-42-21-001-001(A01), AND 51-42-63-001-001(A01).SDR REXA2021062900476Floorbeam · corrodedFS 280 BEAM CORRODED AT LBL 9 WL 72. REMOVED AND REPLACED 280 CROSSBEAM LBL 9 WL 72 IAW SRM 51-42-06-001-001A-01, 51-40-11-001-001-A01, 51-42-10-001-001-A01 AND 52-41-21-001-001-A01.SDR SWIA2021082060517Floorbeam · crackedRH COCKPIT FLOOR BEAM FOUND TO BE CRACKED AT FS280 (C-CHECK RO 8/18/2021) REPAIRED RBL12.00 COCKPIT FLOOR BEAM BETWEEN FS265 & FS280 IAW CRJ900 SRM 53-11-43-201-003-A01 REPAIR TYPE 4. COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA2021081860329Floorbeam · corroded* FLOORBEAM UPPER FLANGE RBL9 AT APPROX. FS797.00 IS CORRODED. (C-CHECK RO 8/16/2021) REPAIRED FLOORBEAM UPPER FLANGE RBL9 APPROX. FS797.00 REF. REO 670-53-41-538 REV - - DATED 2021-7-15. COMPLIED WITH SKYWEST TASK CARD 51-900-1002-SKY.SDR SWIA2021081860328Floorbeam · corroded* FLOORBEAM UPPER FLANGE LBL9 AT APPROX. FS813.70 IS CORRODED. (C-CHECK RO 8/16/2021) BLENDED CORROSION ON FLOORBEAM, UPPER FLANGE AT APPROX. LBL9 FROM FS699.40 - FS855.40 REF. CRJ700 SRM 51-21-06-001-001-A01. EVALUATED BLEND AS OUT-OF-LIMITS. RECIEVED SDR SWIA2021082060595Floorbeam · corroded*CORROSION ON CABIN UNDERFLOOR, FLOOR SUPPORT ANGLE ATTACHED TO FS 280.00. (C-CHECK RO 8/18/2021) REMOVED AND REPLACED FLOOR SUPPORT ANGLE ATTACHED TO F.S. 280.00, REF CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR SWIA2021081060213Floorbeam · crackedSUSPECTED CRACK ON COCKPIT LH FLOORBEAM AT LBL12 JUST FWD OF FS280.00 (C-CHECK RO 8/6/2021) CRACK VERIFIED. REMOVED AND INSTALLED NEW SECTION OF LH FLOORBEAM FROM FS 280.00 TO FS 268.00 REF CRJ700 SRM 53-11-43-201-003-A01. NO NDT DEFECTS NOTED. COMPLIED
Back to JASC 5315