What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 LBL8 TO RBL15 WL180. ; / [01] NO ALLOWABLE DAMAGE FOUND AT SRM FOR THIS PART; PART REQUIRED TO BE REMOVED AND REPLACE IAW SRM 51-10-02-0G-0 PAR 9.; [02] VERIFIED; [03] REMOVED AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947; LBL8 TO RBL 15 WL 180; IAW SRM 51-40-02-0G-0; [04] LOCATED AND DRILLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947; LBL8 TO RBL 15 WL 180 ITEM# 149A8118U29 LOT#1461545 IAW SRM 51-40-05-0G-0 ; OK TO INSTALL; [05] NO ALLOWABLE DAMAGE FOUND AT SRM FOR THIS PART; PART REQUIRED TO BE REMOVED AND REPLACE IAW SRM 51-10-02-0G-0 PAR 9.; [06] VERIFIED OK TO INSTALL.; [07] INSTALLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947; LBL8 TO RBL 15 WL 180 ITEM# 149A8118U29 LOT#1461545 ; IAW SRM 51-40-02-0G-0; DWG#149A8117; [08] UPDATED PARTS USAGE; [09] VERIFIED INSTALLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947; LBL8 TO RBL 15 WL 180 ITEM# 149A8118U29 LOT#1461545 ; IAW SRM 51-40-02-0G-0; DWG#149A8117.; [10] RE-VERIFIED INSTALLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT ACB BS 947; LBL8 TO RBL 15 WL 180 ITEM# 149A8118U29 LOT#1461545 ; IAW SRM 51-40-02-0G-0; DWG#149A8117.