JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2020101421158Floorbeam · crackedCABIN FLOOR BOARD SUPPORT ANGLE IS CRACKED AT STATION 538 LBL 3 THROUGH LBL 5. / REMOVED AND REPLACED CRACKED PANEL SUPPORT AT STA 538; LBL 3 - LBL 24 IAW SRM 51-40-02-0G-0 AND BOEING DWG # 143A0060 REV A. APPLIED CIC IAW AMM 51-21-91-620-802 ATAG WN2707SDR AALA202010309030Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION OF FLOOR BEAM AT STA 986.5 BETWEEN RBL 30 AND RBL 44, MEASURING L=1.0 IN, W=1.0 IN, D=0.087 IN. ACCOMPLISHED PERMANENT REINFORCING SPLICE REPAIR WITH T-CAP, IAW SRM 53-70-51-2R-4.SDR FDEA202010052420Floorbeam · damagedMAIN CABIN FLOOR PANEL SUPPORT HAS PULLED RIVETS THRU UPPER SHIM AT BS 1055 LBL 24.75 TO 45.5. REMOVED AND FABRICATED, INSTALLED NEW FLOOR SUPPORT (PLATE) AT STA 1055 BETWEEN LBL 24.75-LBL 45.5, IAW B 757 SRM 51-40-02-OG, 51-40-05-OG AND BOEING DWG 144N5070 RSDR FDEA202010052419Floorbeam · crackedMAIN DECK STA 900 BETWEEN LBL 24.75-LBL 44.5 FLOOR SUPPORT CRACKED. REMOVED, FABRICATED, AND INSTALLED NEW FLOOR SUPPORT (PLATE) STA 900 BETWEEN LBL 24.75-LBL 44.5, IAW B 757 SRM 51-40-02-OG, 51-40-05-OG AND BOEING DWG 144N5070 REV W AND REV B.SDR LR7A2020100502374Floorbeam · corrodedDURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5312, FOUND THE UNDERDECK FLOOR SUPPORT CORRODED AT FS 196, WL 146, LBL 27-60L. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70. NR 2524.SDR LR7A2020100502372Floorbeam · corrodedDURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5312, FOUND THE UNDERDECK FLOOR TEE BEAM CAP CORRODED AT FS 212. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70. NR 255.SDR LR7A2020100502371Floorbeam · corrodedDURING SCHEDULED C-1 CHECK UNDER JOB CARD HC5312, FOUND THE FS 228 UNDERFLOOR TEE BEAM CAP CORRODED. REPAIR BY REPLACEMENT ACCOMPLISHED, IAW LOCKHEED SMP583 SRM, CH 51-60 & 51-70. NR 2521.SDR SWIA202053791Floorbeam · corrodedFS 280 FLOOR SUPPORT ANGLE FOR COCKPIT FLOOR PANEL 221ALF HAS EVIDENCE OF CORROSION. C-CHECK RO 11/1/2020. REMOVED AND REPLACED THE FS 280 COCKPIT FLOOR SUPPORT ANGLE, REF CRJ700 SRM DRAWING.SDR SWIA202054073Floorbeam · corrodedRT FS 280 BEAM IS CORRODED BEYOND ALLOWABLE LIMITS, IAW CRJ700 SRM. C-CHECK RO 11/12/2020. REPLACED RT BEAM, IAW CRJ-700 SRM. MAJOR REPAIR TASK & FORM M337 COMPLETED AND ATTACHED. PART FOR PART REPLACEMENT, NO WEIGHT CHANGE REQUIRED. REFERENCE ATTACHED COSDR SWIA202054072Floorbeam · corrodedLT FS 280 BEAM CORRODED BEYOND ALLOWABLE LIMITS, IAW CRJ700 SRM, REQUIRES REPLACEMENT. C-CHECK RO 11/12/2020. REPLACED LT BEAM, IAW CRJ-700 SRM. MAJOR REPAIR TASK & FORM M337 COMPLETED AND ATTACHED. PART FOR PART REPLACEMENT, NO WEIGHT CHANGE REQUIRED. RESDR SWAA2020110420116Floorbeam · corrodedCORROSION FOUND AFT CABIN FLOOR FRAME AT STA 986.5 RBL 43 & WL 208.1. INSTALLED UPPER CHORD FLOOR BEAM REPAIR AT STA 986.5 FROM LBL 2' TO RBL 50', PER REF 737-700 SRM 53-70-51-2R-4 REP 4 ALTERNATIVE 1.SDR SWIA202053816Floorbeam · corrodedCOCKPIT FLOOR SUPPORT ANGLE AT FS 280 IS CORRODED. C-CHECK RO 11/3/2020. REPLACED CORRODED COCKPIT FLOOR SUPPORT ANGLE AT FS 280 WITH A SERVICEABLE UNIT, REF CRJ-700 SRM AND DWG. COMPLIED WITH TASK CARD, SEE CONTINUATION CARD FOR DETAILS.SDR SWAA2021072120333Floorbeam · corroded***CORROSION*** ACB IN FLOOR SUPPORT 'T' ANGLE; AT FASTENER; BS 794; RBL 18; WL 157 / REMOVED AND REPLACED ON ACB IN FLOOR SUPPORT 'T' ANGLE AT FASTENER BS794; RBL18; WL157. IAW SRM 51-40-02 AND DWG 146A7500 80641U 05OCT20SDR SWIA202054064Angle · corrodedFS 280.00 LT WEB ANGLE IS CORRODED AT LBL 9.00 AND AT NUTPLATE LOCATION JUST OUTBOARD OF LBL 9.00. C-CHECK RO 11/12/2020. REMOVED AND REPLACED WEB, IAW CRJ-700 SRM. MAJOR REPAIR TASK & FORM M337 COMPLETED AND ATTACHED. PART FOR PART REPLACEMENT, NO WEIGHTSDR SWIA202054062Floorbeam · corrodedFS 280.00 FORWARD "J" ANGLE IS HEAVILY CORRODED. C-CHECK RO 11/12/2020. REMOVED AND REPLACED J ANGLE AT FS 280, IAW CRJ-700 SRM.SDR SWAA2020102820278Floorbeam · corrodedCORROSION, ON FLOOR BEAM AT BS 986.5, RBL 38-44, WL 208.1. FLOOR BEAM AT BS 986.5 RBL 38-44 WL 208.1. DAMAGED AREA FOUND TO BE OUT OF LIMIT, DUE TO THE LOCATION OF THE DAMAGE BEING ON PREVIOUS REPAIR. THEREFORE, REPAIRED FLOOR BEAM AT BS 986.5 RT WL 208.1, SDR SWAA2020102820284Floorbeam · corrodedCORROSION, ON FLOOR BEAM AT BS 986.5, LBL 44, WL 208.1. FLOOR BEAM AT BS 986.5, LBL 44, WL 208.1. DAMAGED AREA FOUND TO BE OUT OF LIMITS DUE TO MORE THAN 50% OF MATERIAL LOSS IN AN AREA OF .5' X .5'. THEREFORE; REPAIRED FLOOR BEAM AT BS 986.5 LT WL 208, IAWSDR IPXA2020102361597Floorbeam · crackedINSPECTION TYPE: 2C LOWER FWD CARGO FLOOR BEAM IS CRACKED AT STA 6-70, X= -57.5 TO X= -60. REPAIRED CRACKED FLOOR BEAM AT STA 6-70, X= -57.5 TO X= -60, IAW VT-SAA EA 011-5310-01-A8598 REV I/R AND UPS EO MD11-5310-78262-A. (MAJOR)SDR SCNA20201014149Floorbeam · corrodedCORROSION ON AFT CARGO COMPARTMENT FLOOR PANEL TEE SPLICE AT STA 767+5. DUE TO NO ALLOWABLE LIMITS IN THE SRM, REPLACED AFT CARGO STA 767 FLOOR PANEL "T" SPLICE PO 772476, IAW SRM 51-10-02-0G-0.SDR KCSA202009301150Floorbeam · corrodedMAIN DECK FLOOR BEAM UPPER CHORD SHOWS EVIDENCE OF CORROSION AT STA 980, BBL 95 LEFT.SDR ASAA2020093033233Floorbeam · corrodedFLIGHT DECK FLOOR PANEL 211AF LANDING IS CORRODED ALL THE WAY AROUND. GROUNDED-YES. REMOVED CORROSION ON STA 270 FLOOR PANEL 211AF LANDING AND FOUND HOLE OUT OF LIMITS, IAW 737-900 SRM 53-10-51-A. REPAIRED STA 270 LATERAL INTERCOSTAL, IAW ALASKA AIRLINES EASDR SWAA2021081520238Floorbeam · corroded***CORROSION*** ON DOUBLER AT FWD CARGO BAY BS500A+12 BL0 WL148.5. / REMOVED CORROSION ON DOUBLER AT FWD CARGO BAY BS500A+12' BL0 WL148.5 MORE 100% MATERIAL LOSS IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 51-10-02. REMOVED AND REPLACED DOUBLER P/N 143SDR SWAA2021072119390Floorbeam · corrodedFWD PIT STA 500I LATERAL FLOOR SUPPORT CORRODED FROM LBL23 TO RBL23 AT WL157 / REMOVED CORROSION ON FLOOR SUPPORT FWD PIT STA 500I. NO PUBLISHED. OUT OF LIMITS. REMOVED + REPLACED FLOOR SUPPORT RAIL IAW SRM 51-40-02-0G-0; 51-40-05-0G-0; AMM 51-21-91-620-802; +SDR SWAA2021060819412Floorbeam · corrodedAFT CARGO COMPARTMENT FLOOR STRUCTURE STA 947; LBL 10 T0 RBL 20 AND WL 180 BULKHEAD LOWER SUPPORT HAS CORROSION ON UPPER AND LOWER SURFACE. / REMOVED + REPLACED AFT CARGO COMPARTMENT FLOOR STRUCTURE STA 947; LBL 10 TO RBL 20 WL 180; BULKHEAD LOWER SUPPORT BRACSDR SWIA202053513Floorbeam · corrodedFLOOR SUPPORT PLATE AT FS 559+48 BETWEEN RBL 9 AND RBL 27 IS CORRODED. C-CHECK RO 10/18/2020. REMOVED AND REPLACED FLOOR SUPPORT PLATE AT FS 559+48 BETWEEN RBL 9 AND RBL 27, IAW CRJ 200 SRM. REF ATTACHED CONTINUATION CARD FOR DETAILS OF WORK PERFORMED.SDR SWIA202053225Floorbeam · crackedAFT WET AREA, FRAME 86 FLOOR BEAM RIGHT SIDE FLOOR SUPPORT IS CRACKED/BROKE OFF, AS MARKED. C-CHECK RO 10/12/2020. REMOVED AND REPLACED FLOOR SUPPORT ON RT FLOOR BEAM AT FR 86, REF SRM.SDR SWIA202053224Floorbeam · crackedAFT WET AREA, FRAME 86 FLOOR BEAM LEFT SIDE FLOOR SUPPORT IS CRACKED/BROKE OFF, AS MARKED. C-CHECK RO 10/12/2020. REMOVED AND REPLACED FLOOR SUPPORT ON LT FLOOR BEAM AT FR 86, REF SRM.SDR SCNA20201008133Floorbeam · corrodedCORROSION FLOOR BEAM UPPER CAP BS 947 RBL 50 WL 208. REMOVED & REPLACED UPPER T CAP PREVIOUS REPAIR AT STA 947.5 RBL 50 WL 208, IAW SCA EA 53-0054 REV 00 AND ATS ER 20-03209 REV IR.SDR SCNA20201008132Floorbeam · corrodedFLOOR BEAM AT BS 947.5 HAS CORROSION AT RBL 5. REMOVED & REPLACED BS 947.5 UPPER T CAP PREVIOUS REPAIR AT RBL 5, IAW SCA EA 53-0054 REV 00 AND ATS ER 20-03209 REV IR.SDR FDEA202009272338Floorbeam · crackedFLOOR BEAM (STUB) AT STA 580 LBL 45.5 IS CRACKED AFT UPPER FLANGE CUT OUT UPPER AFT FLANGE OF FLOOR BEAM (STUB) AT STA 580 LBL 45.5, IAW FEDEX DWG SR57-53-004 REV. FABRICATED AND INSTALLED REPAIR PARTS, IAW FEDEX DWG SR57-53-004 REV, REF FEDEX EA NR F-5310-SDR SWAA2021072120663Floorbeam · corroded***CORROSION*** ON FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS887 LBL8 TO RBL20 WL 168. / REPAIR BY REPLACEMENT FLOOR SUPPORT SPLICE AT AFT CARGO BAY BS 887 LBL 8-RBL 20. LOCATED AND DRILLED HOLES; INSTALLED NUT PLATES; APPLIED CORROSION INHIBITING COMPOUND AND ISDR SWIA202054214Floorbeam · damagedCOMPLY WITH REO REPAIR & REINFORCEMENT FOR FS 559.00 LOWER CAP ANGLES BL 9.00 & 18.00 LT & RT. C-CHECK RO 11/21/2020. COMPLIED WITH REO 601R-53-41-1116. REPAIR & REINFORCEMENT FOR LT & RT FS 559.00 LOWER CAP ANGLES BL 9.00 & 18.00.SDR SWIA202053644Floorbeam · corrodedMAIN CABIN CROSSBEAM AT FS 549.00 FOUND CORROSION UNDER FLOORBEAM AT LBL 9. C-CHECK RO 10/22/2020. BLENDED CORROSION, WITHIN LIMITS, REF REO. ALL STEPS ACCOMPLISHED. SEE CONTINUE CARD FOR DETAILS.SDR SCNA20201008130Floorbeam · corrodedFLOOR BEAM AT BS 986.5 HAS CORROSION FROM LBL 43 TO RBL 47.5. ACCOMPLISHED FLOOR BEAM REPAIR STA 986.5 RBL 50-LBL 50, IAW ATS ER 20-03204 REV IR DATED 09/24/2020 AND SUN COUNTRY EA 53-0053 REV 00.SDR DALA2020092603173Floorbeam · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND AFT CABINFLOOR BEAM CORRODED AT STA 1681 LBL 58. CORROSION REPAIRED, PER ERA 586641-14.SDR IPXA2020092560620Floorbeam · crackedINSPECTION TYPE: 2C CENTER CARGO FLOOR SUPPORT ANGLE CRACK AT STA 1721. REPAIRED CENTER CARGO FLOOR SUPPORT ANGLE AT STA 1721, IAW SRM 51-35-01, VT-SAA EA NR 011-5300-01-A8572 I/R AND UPS EO NR MD11-5300-77923-A. (MINOR)SDR SWIA202053643Floorbeam · corrodedFS 280 RT CROSS BEAM HAS CORROSION. C-CHECK RO 10/22/2020. REMOVED CORRODED RT FS 280 CROSSBEAM AND REPLACED WITH NEW, REFERENCING DWG CRJ 700 SRM. COMPLIED WITH TASK CARD.SDR FDEA202009242304Floorbeam · crackedCENTER CARGO COMPARTMENT, STATION 1741, X=0 FLOOR BEAM FOUND CRACK. CENTER CARGO COMPARTMENT, STATION 1741, X=0 CRACK FLOOR BEAM REMOVED, PER SRM 51-31-01-0G. FLOOR BEAM FABRICATED, PER DOUGLAS DRAWING AFA0040 REVISION V AND INSTALLED PER SRM 51-31-01-0G. SDR DALA2020092503162Floorbeam · corrodedCORROSION LEVEL 2, DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON FLOOR BEAM STA 1681 BETWEEN LBL 24 AND LBL 32 AT WET AREA NR 4. FLOOR BEAM REPAIRED, PER ERA 587886-14.SDR REXA2020102600723Floorbeam · corrodedFS 280.00 FWD J ANGLE CORRODED. REMOVED UNSERVICEABLE 280 CROSSBEAM FWD J ANGLE, IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01 AND INSTALLED SERVICEABLE J ANGLE, IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-010-A01. WVAC EMP STAMP 77SDR SWIA202053642Floorbeam · corrodedCORROSION AT APPROX FS 549 LBL 9 INBOARD ON FLOORBEAM. C-CHECK RO 10/22/2020. REPAIRED DAMAGED FLOORBEAM AT FS 549 LBL 9, REF CRJ700 SRM.SDR SWAA2020102323485Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BSTA 986.5; AT LBL 43; WL 208.1 AT PASSENGER CABIN EA). PERFORMED PERMANENT REPAIR BS 986.5 FLOOR BEAM UPPER HORIZONTAL TEE CAP SPLICE AFT GALLEY AREA AT PASSENGER CABIN, IAW EA NO.1-A53-7848 REV.SDR SWAA000021099Floorbeam · corrodedCORROSION FLOOR BEAM LOCATED BS 986.5 AT RBL 43 AND WL 208.1 AFT GALLEY AREA AT PASSENGER CABIN. PERFORMED PERMANENT REPAIR BS 986.5 FLOOR BEAM UPPER HORIZONTAL TEE CAP SPLICE AFT GALLEY AREA AT PASSENGER CABIN, IAW EA NR 1-A53-7848 REV.SDR IPXA2020101561325Floorbeam · crackedINSPECTION TYPE: 2C LOWER FWD CARGO FLOOR BEAM IS CRACKED AT STA 6-70 AND X= -57.5. REPAIRED CRACKED FLOOR BEAM AT STA 6-70 AND X= -57.50, IAW VT-SAA EA 011-5340-01-A8593 REV I/R AND UPS EO MD11-5340-78173-A. (MAJOR)SDR AALA202009289027Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND 0.25 INCH CRACK ON INTERCOSTAL AT STA 540.5 AND LBL 0-12. REPLACED INTERCOSTAL, REF SRM 51-40-02.SDR AALA202009289025Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND 0.25 INCH CRACK ON INTERCOSTAL AT STA 540.5 BETWEEN RBL 0-12. REMOVED AND REPLACED INTERCOSTAL, REF SRM 51-40-02.SDR SWIA202053933Floorbeam · corrodedFLOOR CROSSBEAM CAP BETWEEN LBL 9.00 AND LBL 27.00 AT FS 589.00 IS CORRODED. C-CHECK RO 11/11/2020. REPLACED UNSERVICEABLE FLOOR CROSSBEAM CAP AT FS 589 BETWEEN LBL 9 AND LBL 27, IAW CRJ200 SRM.SDR SWIA202053932Floorbeam · corrodedFLOOR CROSSBEAM CAP IS CORRODED BETWEEN RBL 9.00 AND LBL 9.00 AT FS 559.00+80. C-CHECK RO 11/11/2020. REMOVED CORRODED CROSS BEAM CAP, INSTALLED NEW SERVICEABLE FLOOR CROSSBEAM CAP BETWEEN RBL 9.00 AND LBL 9.00 AT FS 559.00+80, IAW CRJ 200 SRM REFERENCE CONTSDR SWIA202053931Floorbeam · corrodedFLOOR BEAM CROSSBEAM CAP IS HEAVILY CORRODED BETWEEN RBL 9.00 AND RBL 27.00 AT FS 559.00+80. C-CHECK RO 11/11/2020. REMOVED UNSERVICEABLE FLOOR BEAM CROSSBEAM CAP BETWEEN RBL 9.00 AND RBL 27.00 AT FS 559.00+80 AND INSTALLED SERVICEABLE FLOOR BEAM CROSSBEAM CSDR SWIA202053909Floorbeam · corrodedCABIN FLOORBEAM CAP ON RBL 9.00 IS HEAVILY CORRODED BETWEEN FS 559.00+48 AND FS 559.00+80. C-CHECK RO 11/11/2020. INSTALLED A NEW FLOOR BEAM CAP, IAW REO AS DOCUMENTED ON ATTACHED CONTINUATION CARD. NO WEIGHT AND BALANCE CHANGE, M-337 AND TASK CARD ATTACHED
Back to JASC 5315