SDR UIEA2020051200801Floorbeam · corrodedM/D STA 2260 LBL 1 - 3 FLOOR BEAM FOUND CORROSION.(<P>M/D STA 2260 BL 0 - LBL 20 FLOOR BEAM REPAIRED AS PER SRM 53-00-51-2R-3</P>)SDR SWIA2020060950938Floorbeam · corrodedRT FLOORBEAM HAS CORROSION FS409.00+05 TO 409.00+121 RBL 9. (C-CHECK) RO 4/27/2020 REMOVED AND REPLACED THE RT FLOORBEAM AT RBL 9 BETWEEN FS409.00+05 TO 409.00+121. REF REO.SDR SWIA2020060950937Floorbeam · corrodedLT FLOORBEAM HAS CORROSION FS409.00+05 TO 409.00+121 LBL 9. (C-CHECK) RO 4/27/2020 BLENDED CORROSION ON LT FLOOR BEAM AT FS409.00+05 TO FS409.00+121 REF. FOUND TO BE OUT OF LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS OF REO. COMPLIED WITH TASK CARD.SDR SWAA2020060375826Floorbeam · corrodedCORROSION REPAIR AT FLOORBEAM STA 294.5 (SRM REPAIR 53-10-51--2R-14 REPAIR 14 ) REQUESTING DEVIATION APPROVAL TO ACCOMPLISH REPAIR. INSTALLED CATEGORY A REPAIR AT FLOORBEAM STA 294.5 (UPPER CHORD) BETWEEN LBL 7' AND LBL 3.0' AS PER EA 20-153-00494 REV IR.SDR AALA2020051859010Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 68 AND -Y160.5 / RBL 8. REPAIRED / BLENDED FLOOR BEAM PER SRM 53-00-14 AND EA 305924.SDR SWAA2021071476538Floorbeam · crackedPANEL BREAK SUPPORT AT BS 540; BL 0- RBL 25 IS CRACKED. / REMOVED & REPLACED PANEL BRAKE SUPPORT-36 PER SRM 51-40-02-0G-0 & AIPC 53-31-00-05 PG 31 59899U 13MAY20SDR SWIA2020061051034Floorbeam · crackedBS 280 FLOORBEAM ANGLE RBL 12, SUSPECTED CRACK IN RADIUS. REMOVED AND REPLACED THE FLOORBEAM ANGLE WITH NEW, LOCATED,DRILLED AND INSTALLED THE NEW ANGLE IAW SRM AND DWG.SDR SWIA2020061051033Floorbeam · corrodedBS 280 FLOORBEAM ANGLE ON FRONT HAD EVIDENCE OF CORROSION ON UPPER RADIUS AND IN OTHER MARKED LOCATIONS. REMOVED AND REPLACED FLOORBEAM ANGLE WITH NEW IAW DWG, AND SRM. COMPLIED WITH CARD.SDR SWIA2020061051032Floorbeam · corrodedBS 280 FLOORBEAM ON LT SIDE WAS CORRODED. EVALUATED CORROSION FROM THE FLOORBEAM, 100% MATERIAL LOSS, FOUND TO BE OUT OF LIMITS IAW SRM. REMOVED CORRODED FLOORBEAM ANGLE AND INSTALLED NEW IAW DWG, AND SRM.SDR SWIA2020052950909Floorbeam · corrodedSPOTS OF POSSIBLE CORROSION FOUND IN MULTIPLE LOCATIONS ALONG RBL 9 BETWEEN FS 409 - FS 409+128 (48 MONTH) RO 5/28/2020. REMOVED AND REPLACED FLOORBEAM CAP SECTION AT RBL 9 BETWEEN FS409.00-FS409+112. REF REO AND DWG. SEE CONTINUE CARD FOR DETAILS.SDR SWIA2020052950908Floorbeam · corrodedSPOTS OF POSSIBLE CORROSION FOUND IN MULTIPLE LOCATIONS ALONG LBL 9 BETWEEN FS 409 - FS 409+128 (48 MONTH) RO 5/28/2020. REMOVED AND REPLACED FLOORBEAM CAP BETWEEN LBL9 FS409 TO FS409+128 REF REO AND DWG.SDR SWIA2020052950907Floorbeam · corrodedCORROSION FOUND IN MULTIPLE LOCATIONS ALONG RBL9, BETWEEN FS409+128 AND FS559.00 (48 MONTH) RO 5/28/2020. REPLACED PRESSURE FLOORBEAM CAP PER REO DWG SRM. COMPLETED TASK CARD.SDR SWIA2020052950906Floorbeam · corrodedCORROSION FOUND IN MULTIPLE LOCATIONS ALONG LBL9, BETWEEN FS409+128 AND FS559.00 (48 MONTH) RO 5/28/2020. REPLACED PRESSURE FLOORBEAM CAP PER REO. COMPLETED TASK CARD.SDR COEA2020051510911Floorbeam · corrodedWO 213191 NR 100073 HEAVY CHECK COE/MAJOR REPAIR: FLOORBEAM 33 EXFOLIATED ON AFT SIDE BETWEEN L/H SEAT TRACKS. LEVEL 2 CORRECTIVE ACTION: REPAIRED PER SRM 530000-300-839-A01.SDR CALA2020050900938Floorbeam · corrodedMAIN CABIN AFT WET AREA STA 986.5 FROM LBL 22 TO LBL 43 FLOOR BEAM HAS CORROSION ON UPPER FLANGE REF AR N/R 99880669 AFTER REMOVAL OF CORROSION FOUND OUT OF LIMIMTS PER ECRA 5311-01330 REPAIRED FLOOR BEAM SECTION UPPER CHORD STA 986.5 BETWEEN LBL 22 AND LBL 43SDR SWAA2021072274955Floorbeam · crackedCENTER CABIN STA 540 BL-0 LATERAL FLOOR SUPPORT STRAP IS CRACKED. [DOT 124-015] / REPLACED LATERAL FLOOR SUPPORT @ CENTER CABIN STA 540 BL-0 AS PER B737-700 SRM 51-40-02-0G-0SDR SWAA2021042775150Floorbeam · corroded'CORROSION' LH AFT CABIN FLOOR @ STA 986.5 LBL43 FLOOR BEAM HAS CORROSION. (18015) UPPER TCHORD REPAIR COMPLETED AT STA 986.5 (ENTIRE UPPER TCHORD REPLACED) ON NR#W147048; IAW B737700 SRM 5370512R4 REPAIR 4.SDR SWAA2021042774833Floorbeam · corroded*** CORROSION *** FOUND FWD WET AREA FLOOR SUPPORT BEAM UPPER CHORD AT STA 312 AND LBL 6 MKD DOT 60025 WL 208.0. INSTALLED CATEGORY A REPAIR AT STA 312 LBL 6' WL 208.0 IRW B737700 SRM 5310512R15 REPAIR 15.SDR FDEA2020060341116Floorbeam · corrodedCENTER CARGO COMPARTMENT, CORROSION ON FRAME, ON BOTTOM SIDE OF THE FLOOR SUPPORT, AT STA 1781 LBL 46 (MARKED NR 8). COMPLETED REPAIR ON FLOORBEAM STA 1781 LBL 46 PER EA 1-5300-T0354162. TITLE, FUSELAGE, GENERAL CORROSION ON FLOORBEAM STA 1781 UPPER CHORD TASDR SWAA2020060274835Floorbeam · corrodedCORROSION FOUND FWD WET AREA FLOOR SUPPORT BEAM UPPER CHORD AT STA 294.5 AND LBL 4 TO LBL 6. INSTALLED CATEGORY A REPAIR AT FLOORBEAM STA 294.5 UPPER CHORD BETWEEN LBL 7 AND LBL 13.0 AS PER EA 20-153-00494 REV IR.SDR FDEA2020052641039Floorbeam · corrodedAFT CARGO AT APPROX STA 1842 FLOORBEAM ON TOP SECTION HAS MINOR SURAFCE CORROSION AT APPROX RBL 50 (MARKED). REMOVED AND REPLACED FLOORBEAM TOP SECTION ( ANGLE SUPPORT ) AT STA APPROX 1842 WITH A NEW PART REF SRM 51-31-01-0G AND DAC DRAWING AGA7170.SDR FDEA202005040888Floorbeam · corrodedMAIN CABIN FLOOR FRAME UPPER CAP SHOWS EVIDENCE OF POSSIBLE CORROSION BL0 TO BL20R BS 1020. REMOVED CORR ON FLOOR SUPPORT STA 1020 BLO TO BL20R IAW B757 SRM 51-10-02. FOUND TO BE OUT OF LIMITS DUE TO EXFOILATION IAW B757 SRM 53-00-51-1A FIG 101. REMOVED FLSDR UATA2020050400000Floorbeam · corrodedFOUND INTERGRANULAR CORROSION WHERE NUT PLATES WERE ATTACHED ON THE BOTTOM OF THE CAP STRIP OF FLOOR FRAME #11. SPLICED IN A NEW SECTION OF FRAME CAP PER CASA SRM.SDR SWAA2021072274599Floorbeam · corrodedAFT CARGO LATERAL FLOOR SUPPORT HAS CORRODED NUT PLATES AT 727D+5 BUT LINE 22 LEFT TO 22 RIGHT; WL 153.8 / REMOVED CORRODED T STRAP AND INSTALLED NEW T STRAP ASSY AT STA 727D+5; PER REF SRM 51-40-02-0G-0 AND DRAWING N. 146A7500SDR SWAA2021072274600Floorbeam · corrodedAFT CARGO LATERAL FLOOR SUPPORT AT BS 769 LEFT BL 22 TO RIGHT BUT LINE HAS CORRODED NUT PLATES (2EA). / REMOVED AND REPLACED NUT PLATE AT FLOOR SUPPORT LEFT BL 22 BS769 IAW B737-700 SRM 51-40-02 (2EA)SDR SWAA2020060474500Floorbeam · corrodedCORROSION CABIN FLOORBEAM UPPER CAP, UPPER SURFACE, BS 986.5, LBL 50', WL 208.1 (L2 DOOR AFT GIRT BAR FLOOR FITTING AREA). INSTALLED CATEGORY A REPAIR AT FLOORBEAM UPPER CAP, STA 986.5 FROM RBL 50' TO LBL 50' (ENTIRE T CAP REPLACEMENT) IRW SRM 53-70-51-2R-4 RSDR FDEA2020050420874Floorbeam · crackedFUSELAGE - MAINFRAME - STA 580 FLOOR BEAM SPLICE SEGMENT UPPER AFT FLANGE CRACK AT LBL 45.5 TRIMMED OUT UPPER AFT FLANGE OF FLOOR BEAM SPLICE SEGMENT PER FEDEX DWG SR57- 53-004 REV - , FABRICATED AND INSTALLED REPAIR PARTS PER FEDEX DWG SR57-53-004 REV - SDR CALA2020050200913Floorbeam · corroded{B737-53-3-0737} CABIN FLOOR BEAM UPPER SURFACE STA 328 ABOUT 8IN FROM R/H INNER CHORD HAS CORROSION AROUND NUTPLATE. REF AAR N/R 9172546 PERFORMED FLOOR BEAM T CHORD REPAIR AT MAIN CABIN STA 328 FROM BL 0 TO RBL 64 (INNER CHORD) AS PER B737 SRM 53-10-51 ACCOMSDR SWIA2020060951016Floorbeam · corrodedCORROSION FOUND ON FS280 FLOOR SUPPORT CRAWLWAY ANGLE BETWEEN STGR 25R AND STGR 25L. (C-CHECK) RO 4/23/2020 - INSTALLED NEW FLOOR SUPPORT ANGLE AT FS280 BETWEEN STGR 25R AND STGR 25L REF. CRJ700 SRMSDR SWAA2020051845777Floorbeam · corroded***CORROSION*** MULTIPLE POINTS OF CORROSION ON FLIGHT DECK FLOOR SUPPORT; BS 270; LBL 9 - RBL 9; WL 208 (MARKED) / REMOVED AND REPAIRED DAMAGE PART OF FLIGHT DECK FLOOR SUPPORT BS 270 LBL 15-RBL15 WL 208 I.A.W EA #1-A53-13812 REV 1 DATED 08FEB11 CONFIGURATIONSDR CALA2020050200898Floorbeam · corrodedAFT CABIN FLOOR BEAM UPPER SURFACE HAS CORROSION SPOT AT FITTING B.S.947.5 R.BL.50". (REF NR 9172585) FLOOR BEAM OUT OF LIMITS CUTOUT UPPER T SECTION AND INSTALLED REPAIR FROM STA 947.5 BETWEEN LBL 7.80 TO RBL 51.60 AS PER B737 SRM 53-70-51 REPAIR 5.SDR FDEA202004260791Floorbeam · corrodedMAIN CABIN FLOOR FRAME UPPER CAP SHOWS EVIDENCE OF POSSIBLE CORROSION BL0 TO RBL20 BS 1060. REMOVED CORR ON FLOOR SUPPORT STA 1060 BL0 TO BL20R IAW B757 SRM 51-10-02 100% MAT. LOSS OUT OF LIMITS IAW B757 SRM 53-00-51 FIG 101. REMOVED SUPPORT IAW B757 SRM 51-04SDR FDEA2020042760791Floorbeam · corrodedMAIN CABIN FLOOR FRAME UPPER CAP SHOWS EVIDENCE OF POSSIBLE CORROSION BL0 TO RBL20 BS 1060. REMOVED CORR ON FLOOR SUPPORT STA 1060 BL0 TO BL20R IAW B757 SRM 51-10-02 100% MAT. LOSS OUT OF LIMITS IAW B757 SRM 53-00-51 FIG 101. REMOVED SUPPORT IAW B757 SRM SDR SWAA2021080344829Floorbeam · crackedBREAK PANEL IS CRACKED STA 540; AT RBL 1; WL 208. / REMOVED CRACKED BREAK PANEL BS 540; RBL 1 WL 208 AND LOCATED DRILLED AND INSTALLED NEW BREAK PANEL PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND BOEING DWG 143A0060SDR SWAA2021080344828Floorbeam · crackedBREAK PANEL IS CRACKED STA 540; AT LBL 1; WL 208. / REMOVED CRACKED BREAK PANEL BS 540 LBL 1 WL 208 AND LOCATED DRILLED AND INSTALLED NEW BREAK PANEL PER SRM 51-40-02-0G-0; SRM 51-40-05-0G-0; AND BOEING DWG 143A0060SDR UIEA2020042800895Floorbeam · corrodedM/D-STA 1740 LBL 11.33" - RBL 11.33" FLOOR BEAM LOWER SURFACE FOUND CORROSION.(<P>CABIN-STA 1740 LBL 0 TO LBL 20" FLOOR BEAM UPPER CAP REPAIRED IAW RI-53-65-14001 REV. A. </P>)SDR UIEA2020042800896Floorbeam · corrodedM/D STA 2060 LBL 11.33" - RBL 11.33" FLOOR BEAM LOWER SURFACE FOUND CORROSION.(<P>CABIN-STA 2060 LBL 22 TO RBL 3" FLOOR BEAM UPPER CAP REPAIRED IAW RI-53-65-14002 REV. A.</P>)SDR UIEA2020042800897Floorbeam · corrodedM/D STA 2160 LBL 11.33" - RBL 11.33" FLOOR BEAM FOUND CORROSION.(<P>CABIN-STA 2160 LBL 21 TO RBL 21" FLOOR BEAM UPPER CAP REPAIRED IAW SRM 53-00-51-2R-3 REPAIR 3 FIG 201.</P>)SDR WVER2020042493502Floorbeam · corrodedFLOOR BEAM AT FS 680.00 RBL 9.0 IS CORRODED.SDR SWIA202005070547Strap · corroded*FS559.00 FLOOR BEAM STRAP BETWEEN LBL 27 AND PRESSURE FLOOR SILL CORRODED IN SEVERAL AREAS (MARKED) (48 MO INSP) RO 5/6/2020 REMOVED CORRIOSON AND MEASURED REMNAING MATERIAL THICKNESS. FOUND RAMAINING MATERIAL THICKNESS TO BE OUT OF LIMITS REF CRJ 200 SDR DALA2020050402347Floorbeam · corroded(AIRCRAFT 3163, L/P 1551626) CORROSION FLOOR BEAM -Y1292 LOCATED BETWEEN FR64 TO FR66 AT AFT GALLEY AREA (SSI 534147). CORRECTIVE ACTION: REPLACED FLOOR BEAM AS PER A319 SRM 51-72-11 AND 51-42-11 AND ERA 586398-14 REV. ORIGINAL SECTION I AND DWG 14N0031 ATTACHSDR DALA2020050402345Floorbeam · corroded(AIRCRAFT 3163, L/P 1551628) CORROSION FLOOR BEAM +Y1292 LEVEL FROM FR66 TO FR68 AT AFT GALLEY AREA (SSI 534147). CORRECTIVE ACTION: REPLACED FLOOR BEAM AS PER A319 SRM 51-72-11 AND SRM 53-41-14-03A DWG D53472780000 ISSUE K RELEASE DATE 26APR18. RII INSPECTIONSDR SWAA2020052044417Floorbeam · corroded***CORROSION*** ON BS 986 BEAM UPPER CHORD LBL45 WL 208 / REMOVED CORROSION ON B.S986 FLOOR BEAM UPPER CHORD LBL45 WL208 IN AN AREA OF 1' X 1.5'; REMAINING .088'; ORIGINAL MAT' IS .150' AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1; ACCOMPLISHED B.S 986SDR IPXA2020042254539Floorbeam · corrodedINSPECTION TYPE:SEG1FLOOR BEAM AT COCKPIT FLOOR UNDER CAPT SEAT CORRODEDREMOVED, FABRICATED, INSTALLED NEW BEAM PER DWG 141N5810-604SDR SWAA2021081743765Floorbeam · crackedCABIN FLOORBOARD BREAK SUPPORT ASSY CRACKED AT STA 540 RIGHT OF CENTER. / REMOVED AND REPLACED CABIN FLOORBOARD RH BREAK SUPPORT ASSY AT STA 540 IAW AMM 20-50-11 AND SRM 51-40-02SDR SWAA2021081743764Floorbeam · crackedCABIN FLOORBOARD BREAK SUPPORT ASSY CRACKED AT STA 540 LEFT OF CENTER. / REMOVED AND REPLACED CABIN FLOORBOARD LH BREAK SUPPORT ASSY AT STA 540 IAW AMM 20-50-11 AND SRM 51-40-02SDR IPXA2020060155981Floorbeam · cracked3C SUB FLOORBEAM AT APPROX STATION 6 - 73, LONGERON 43, LT CORNER IS CRACKED AT ITS ANGLE CHANGE. REMOVED CRACKED SUB FLOORBEAM, FABRICATED AND INSTALLED AT STATION 6 - 73, LONGERON 43 LT IAW SRM 51-31-01.SDR DALA2020042302297Floorbeam · corroded(AIRCRAFT 3163, L/P 1551020) CORROSION FLOOR BEAM -Y1292 LOCATED BETWEEN FR66 TO FR68 AT AFT GALLEY AREA (SSI 534147). CORRECTIVE ACTION: REPLACED FLOOR BEAM PER SRM A319 51-72-11 AND 51-42-11 DWG #D53472780 ISSUE J. RII INSPECTION ACCOMPLISHED.SDR IPXA2020042254501Floorbeam · puncturedINSPECTION TYPE:SEG1FLOOR BEAM WEB STA247 LBL 20-36.20 HAS PUNCTUREREPAIRED T CHORD WITH REPAIR ANGLE AND WEB WITH DOUBLERSDR JR2R202004212268Floorbeam · corrodedRH CENTER FLOOR BEAM HAS CORROSION BETWEEN FRAMES 87 AND 88. FOUND TO BE OUT OF LIMITS. REPAIRED FLOOR BEAM IAW EMB-175 SRM 53-23-10.
Back to JASC 5315