What was found
CORROSION FOUND FWD WET AREA FLOOR SUPPORT BEAM UPPER CHORD AT STA 294.5 AND LBL 4 TO LBL 6. INSTALLED CATEGORY A REPAIR AT FLOORBEAM STA 294.5 UPPER CHORD BETWEEN LBL 7 AND LBL 13.0 AS PER EA 20-153-00494 REV IR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND FWD WET AREA FLOOR SUPPORT BEAM UPPER CHORD AT STA 294.5 AND LBL 4 TO LBL 6. INSTALLED CATEGORY A REPAIR AT FLOORBEAM STA 294.5 UPPER CHORD BETWEEN LBL 7 AND LBL 13.0 AS PER EA 20-153-00494 REV IR.