JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020011600345Floorbeam · corrodedCORROSION LEVEL: 2. CORROSION FLOORBEAM +Y1292 FR16 FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 BTW FR.12 TP FR.24 IN FWD GALLEY AREA AND FASTENERS AS PER SRM 51-72-11 AND DWG D53110920 & D53112812.SDR IPXA2020021252065Floorbeam · corrodedINSPECTION TYPE:2CAFT CARGO FLOOR BEAM SUPPORT ANGLE IS CORRODED BETWEEN STA. X= -7 TO -9.5 AT Y= 1841.REPAIRED CORRODED AFT CARGO FLOOR BEAM SUPPORT ANGLE BETWEEN STA. X= -7 TO -9.5 AT Y= 1841 IAW VT-SAA EA 011-5316-01-A8007 REV. I/R AND UPS EO MD11-5310-754SDR FDEA2020020650274Floorbeam · corrodedMAIN CARGO DECK AT APPROX STA 1481 RBL 100 FLOOR SUPPORT HAS EXFOLIATION CORROSION. MARKED #4 REMOVED AND REPLACED CORRODED FLOOR SUPPORT REF DAC DWG NEA6018 AND SRM 51-31-01 VOL. 2.SDR FDEA2020020650273Floorbeam · corrodedMAIN CARGO DECK AT APPROX STA 1501 LBL 9 FLOOR SUPPORT HAS EXFOLIATION CORROSION. MARKED #7 REMOVED AND REPLACED CORRODED FLOOR SUPPORT REF DAC DWG NEA6018 AND SRM 51-31-01 VOL. 2.SDR FDEA2020020650271Floorbeam · corrodedMAIN CARGO DECK AT APPROX STA 1381 LBL 9 FLOOR SUPPORT HAS EXFOLIATION CORROSION. MARKED #6 REMOVED AND REPLACED CORRODED FLOOR SUPPORT REF DAC DWG NEA6018 AND SRM 51-31-01 VOL. 2.SDR FDEA2020020415256Floorbeam · corrodedMAIN CARGO DECK AT APPROX STA 1361 LBL 100 FLOOR SUPPORT HAS EXFOLIATION CORROSION. MARKED #8 REMOVED AND REPLACED CORRODED FLOOR SUPPORT AEA0394-1 REF DAC DWG NEA6018 AND SRM 51-31-01 VOL. 2.SDR FDEA2020013050249Floorbeam · corrodedUPPER CARGO, SEAT TRACK APROX STATION 1741 RBL 100 SHOW SIGNS OF CORROSION AROUND SEVERAL NUT PLATES (VIEWED FROM CTR CARGO) REMOVED AND REPLACED FLOOR SIPPORT AT STATION 1741, RBL -80 TO RBL -108 PER DAC DWG AFA3853, INSTALLED FLOOR SUPPORT AFA3853-10 PERSDR REXA2020012850082Floorbeam · corroded"AWR, IN REF NRC S/N 00236, AFTER ANGLE REMOVAL, CORROSION WAS FOUND ON FLOOR SUPPORTS AT PASSENGER SURROUND AREA LOWER SILL.
"FWD FLOOR SUPPORT STA 314 AT PASSENGER SURROUND AREA LOWER SILL WAS REPLACED FOR A NEW ONE PER CRJ-900 SRM 51-42-06-SDR AALA2020012219020Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM AT BS 967 AND RBL 28. REMOVED CORROSION BY BLENDING ONLY REMAINING MATERIAL WITHIN LIMITS PER AARD 53-00-00-8. AREA WAS TREATED, PRIMED AND TOP COAT APPILED PER SRM 51-20-01.SDR DALA2020011600344Floorbeam · corrodedCORROSION FLOORBEAM -Y765 BTW FR66 TO FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y765 FR 68 AT AFT GALLEY AREA AS PER SRM 51-72-11, SRM 51-42-11 AND DWG #D53472780.SDR DALA2020011600343Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y1292 FR 68 AT GALLEY AREA ASPER SRM 51-72-11 SRM 51-42-11 AND DWG:D53472780.SDR FDEA2020011650132Floorbeam · corrodedBULK CARGO COMPARTMENT FLOORBEAM UPPER SURFACE IS CORRODED BS 66 - BS 66 BL32 RBL42. REMOVE AND REPLACE CROSSBEAM IAW SRM 51-40-21.SDR KCSA202001151006Support Web · crackedCRACK AT STA 1220, LBL 112 IN MAIN DECK FLOORBEAM SUPPORT WEB.SDR SWAA2020011427309Floorbeam · corrodedAFT WET AREA; TOP AND BOTTOM OF FLOOR STRUCTURE AT R/H STA 986; RBL 33.5; WL 208; HAS A FASTENER HOLE CORRODED. / BLENDED CORROSION AT TOP AND BOTTOM SURFACE OF FLOOR BEAM TCAP AT STA 986 RBL 33.5 WL 208; ORIGINAL THICKNESS .126'; REMAINING .100' LOSS OF .025'SDR SWAA2021060427307Floorbeam · corrodedAFT WET AREA; TOP OF FLOOR STRUCTURE AT R/H STA 986; RBL 43; WL 208; HAS A FASTENER HOLE CORRODED. / BLENDED CORROSION AT TOP AND BOTTOM SURFACE OF FLOOR BEAM T-CAP AT RH STA 986; RBL 43; WL 208. ORIGINAL THICKNESS= .125' REMAINING =.098 LOSS OF .023'FOUND TO SDR SWAA2020020544997Floorbeam · corrodedFLOOR BEAM UPPER SURFACE CORRODED AT BS. 986.5, BETWEEN RBL 25 TO RBL 38. / REPAIRED CHORD PER SRM.SDR FDEA2020013040246Floorbeam · corrodedUPPER CARGO- APROX STATION 1741 RBL 118, FLOOR BOARD SUPPORT SHOWS SIGNS OF CORROSION (VIEWED FROM CTR CARGO) REMOVED AND REPLACED FLOOR SIPPORT AT STATION 1741, RBL -80 TO RBL -108 PER DAC DWG AFA3853, INSTALLED FLOOR SUPPORT AFA3853-10 PER SRM 51-35-01 VSDR SWAA2020012240683Floorbeam · corrodedAFT WET AREA, TOP AND BOTTOM OF FLOOR STRUCTURE FASTENER HOLE CORRODED AT BS. 986, RBL 33.5. REPAIRED T CAP IAW SRM.SDR SWAA2020012240682Floorbeam · corrodedAFT WET AREA TOP AND BOTTOM OF FLOOR STRUCTURE FASTENER HOLE CORRODED AT BS. 987, RBL 44. R&R WEB IAW SRM AND DWG.SDR SWAA2020012240681Floorbeam · corrodedAFT WET AREA, TOP OF FLOOR STRUCTURE HAD A FASTENER HOLE CORRODED BS. 986, RBL 43. REPAIRED T-CAP IAW SRM.SDR FDEA2020011640123Floorbeam · corrodedBULK CARGO COMPARTMENT FLOORBEAM UPPER SURFACE IS CORRODED BS 67 - BS 67, BL29 RBL39 REMOVED AND REPLACED CROSSBEAM IAW SRM 51-40-21SDR VNAA2020011499905Floorbeam · corrodedAFT CARGO BAY FLOORBEAM AT LBL 9 HAS MULTIPLE AREAS OF CORROSION ON TOP OF THE BEAM BETWEEN FS 1007 AND FS 1064. IAW SRM 53-61-43-101-001-A01 NO DAMAGE ALLOWED TO FLOORBEAMS IN THIS LOCATION REQUIRES ENGINEERING REPAIR. BLENDED OUT DAMAGE IAW REO 670-53-61-162SDR VNAA2020011499904Floorbeam · corrodedAFT CARGO BAY FLOOR BEAM AT LBL 27HAS MULTIPLE AREAS OF CORROSION ON TOP OF THE BEAM BETWEEN FS 992 TO FS 1033. COMPLIED WITH REO 670-53-61-1626.SDR VNAA2020011499903Floorbeam · corrodedAFT CARGO RBL 9 AND RBL 27 FLOORBEAMS HAVE MULTIPLE AREAS OF CORROSION ON TOP OF BEAMS BETWEEN FS 1007 TO FS1064 ON RBL 9 AND FS 1060 TO FS 1075 ON RBL 27.0. IAW SRM 53-61-43-101-001-A01 NO DAMAGE ALLOWED TO FLOOR BEAMS IN THIS LOCATION REQUIRES ENGINEERING RESDR SWAA2020021941524Floorbeam · crackedFLOOR BEAM UPPER CHORD CRACKED AT BS. 727B, RBL 45.5. / REPAIRED FLOOR BEAM PER EA.SDR ASAA2020021032103Floorbeam · corrodedMAIN CABIN FLOOR BEAM HAS SURFACE CORROSION AT STA C20 RBL240MM. GROUNDED - YES. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT RAIL REF A320 SRM 51-72-11 AND AIRBUS DWG D53111406 ISSUE "B" PO# 964396.1SDR SWAA2020011227719Floorbeam · corrodedFLOOR BEAM 947.5 HAS SURFACE CORROSION ON BOTH SIDES OF THE RIGHT HAND AFT LAV OUTBOARD FLOOR MOUNT RBL 52 INCHES / REPAIRED STA .947.5 FLOOR BEAM (ENTIRE UPPER 'T' LBL 59 TO RB L59) IAW SRM 53-70-51-2R-5 AND EA-REPAIR-53EA-07685. ADDITIONAL SIGN OFFS ON SA-M SDR SWIA2020030248897Floorbeam · corrodedF.S. 589 FLOOR CROSS BEAM IS CORRODED AROUND THE NUTPLATE HOLESBETWEEN LBL9 AND LBL27 (C-CHECK) RO 2/27/2020 REMOVED AND REPLACED CAP STRIP AT FS 589 BETWEEN LBL9 AND LBL27 IAW CRJ200 SRM. (PN 601R35031-165)SDR SWIA2020020748320Floorbeam · corrodedFS 280.0 BL 0.0 UPPER SPLICE STRIP IS CORRODED. (C-CHECK) RO 2/05/2020 FS 280.0 FLOOR BEAM UPPER SPLICE STRIP WAS EXFOLIATED AT 100%, PART IS "OUT OF ALLOWABLE LIMITS", REMOVED AND REPLACED WITH NEW STRIP PN CC670-34097-1SB,REF CRJ-700 SRM. COMPLIED WITH SDR SWAA2020012874786Floorbeam · crackedCRACK FLOOR STRUCTURE CHANNEL AT BS 540 BETWEEN BL 0 TO RBL 24.5 AT PASSENGER CABIN (1 EA). / REPLACED CHANNEL (BREAK ASSY) AT BS 540 BETWEEN BL0 TO RBL 24.5 FLOOR STRUCTURE PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9.SDR SWAA2020011127640Floorbeam · corrodedFWD CARGO STA 500 I RBL18 FLOOR SUPPORT HAS CORROSION MARKED / REMOVED AND REPLACED FLOOR SUPPORT P/N N3A9485-35 FROM LBL 24.5 TO RBL 24.5 PER ' 'SRM 51-40-02. SEE SAM 326 A1164662 FOR INDIVIDUAL SIGNED OFF.SDR SWAA2021082227641Floorbeam · corrodedFWD CARGO STA 500 I LBL 18 FLOOR SUPPORT HAS COROSSION MARKED / REMOVED AND REPLACED FLOOR SUPPORT P/N 143A9485-35 AT STA 500I FROM LBL 24.5 TO RBL 24.5 PER SRM 51-40-02. (INSPECTOR :D54)SDR SWIA2020030248879Floorbeam · corrodedRBL 9 FLOOR BEAM CAP IS CORRODED BETWEEN FS 409.00+128 AND 424.00. (C-CHECK) RO 2/27/2020 REMOVED CORROSION FROM RBL 9 FLOOR BEAM AND FOUND IT WAS OUT OF LIMITS. REMOVED DAMAGED SECTION AND FABRICATED FILLER AND ANGLE AND INSTALLED REPAIR IAW BOMBARDIER RESDR SWIA2020021848675Floorbeam · corrodedCORROSION ON LH 280 BEAM (C-CHECK) RO:2/14/2020 REMOVED AND REPLACED LH 280 BEAM REF CRJ 700 SRM AND DWG REV NC DATED 2009-11-26. COMPLIED WITH SKYCARD (CL600-2C10) STRUCTURAL MAJOR REPAIR (**RII**) AND M-337SDR R61A2020012811100Floorbeam · corrodedDURING HEAVY CHECK. FLOOR PANEL SUPPORT CLIP ON FLOOR BEAM AT FR86 HAS CORROSION. REPLACED SUPPORT CLIP IAW SRM 51-41-01. AIRCRAFT REMAINS OUT OF SERVICE FOR HEAVY CHECK.SDR AALA202001221027Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM UPPER "T" CAP AT BS 947 AND RBL 51. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5.SDR AALA2020012217910Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CABIN WET AREA FLOOR BEAM UPPER "T" CAP AT BS 947 AND LBL 24. REPAIRED FLOOR BEAM PER SRM 53-70-51-2R-5.SDR SWIA2020021848727Attach Angle · crackedATTACH ANGLE CRACKED FS 280 RBL12 COMMON TO CROSS BEAM AND INTERCOSTAL (C-CHECK) RO:2/14/2020REPLACED NEW ANGLE AT FS 280.00 AT RBL 12 REF CRJ-700 SRM.SDR SWIA2020021848673Floorbeam · corrodedCORROSION ON LONG BEAM UPPER FLANGE FS 295 RBL 9 (C-CHECK) RO:2/14/2020 INSTALLED (1EA) NEW RBL 9.0 FLOOR BEAM AND ALL SPLICE REPAIR PARTS (1EA)(-7) LOWER FLANGE,(1EA)(-11) CLEAT,(2EA)(-13) SPLICE ANGLE, AND (2EA)(-15)UPPER ANGLE ON RBL 9.0 BETWEEN FSSDR SWIA2020021148408Floorbeam · corroded* CORROSION DETECTED ON AFT SIDE OF F.S. 280.00 ON CRAWL BOARD SUPPORT "ANGLE" (MARKED). (C-CHECK) RO 2/07/2020 REMOVED AND REPLACED CRAWL AWAY FLOOR SUPPORT ANGLE AT F.S. 280.0, REF CRJ 700 SRM.SDR SWIA2020021148395Floorbeam · crackedFLIGHT DECK BL12 LH FLOOR BEAM HAS EVIDENCE OF CRACK IN RADIUS AT FS280 FLOOR POST ATTACHMENT. (C-CHECK) RO 2/07/2020 REMOVED AND INSTALLED FABRICATED FLIGHT DECH BL12 LH FLOOR BEAM REF. CRJ-700 SRM. COMPLIED WITH MAJOR REPAIR M-337 AND TASK CARD.SDR SWIA2020021148394Floorbeam · corrodedFS 280 RH BEAM TOP FLANGE RADIUS CORRODED (C-CHECK) RO 2/07/2020 REMOVED AND REPLACED RH 280.0 BEAM, REF CRJ 700 SRM AND BOMBARDIER DWG. COMPLIED WITH SKYWEST TASK FOR A STRUCTURAL MAJOR REPAIR. COMPLIED WITH SWA M-337.SDR SWIA2020020648262Floorbeam · corrodedFS 559.0 LH FLOOR SUPPORT PLATE CORRODED LBL 27 TO LBL 40 (C-CHECK) RO 2/04/2020 REMOVED CORROSION ON FLOOR SUPPORT PLATE ON FS 559.0 LBL27 TO LBL 40. FOUND TO BE OUT OF LIMITS. ORIGINAL THICKNESS .050", REMAINING .038", WITH TOTAL LOSS OF .012". FABRICATESDR SWAA2020010913087Floorbeam · crackedFWD CARGO; LEFT OF CENTER FLOOR BOARD SUPPORT BRAKE CRACKED AT STA 540 IN FWD A/C DIST BAY. / REMOVED AND REPLACED FWD CARGO LEFT OF CENTER FLOOR BOARD SUPPORT BRAKE AT STA 540 IN FWD A/C DIST BAY IAW SRM 51-40-02SDR SWIA2020031049119Floorbeam · cracked*LH FLOORBEAM POSSIBLE CRACK AT FS280. FLAGGED (C-CHECK) RO 3/6/2020 REMOVED AND INSTALLED NEW LH FLOORBEAM AT FS 280 REF. CRJ 900 SRM. COMPLIED WITH TASK CARD.SDR COEA2020030404801Floorbeam · corrodedWO 209330 NR 200276 HEAVY CHECK COE/MINOR REPAIR: FLOORBEAM 7 COPILOTS SIDE UPPER SURFACE HAS LEVEL 2 CORROSION. CORRECTIVE ACTION: REPLACED WITH OEM PART.SDR SWIA2020021848672Floorbeam · corrodedRH 280 BEAM CORRODED (C-CHECK) RO:2/14/2020REMOVED AND REPLACED RH 280 BEAM REF CRJ 700 SRM AND DWG COMPLIED WITH SKYCARD (CL600-2C10) STRUCTURAL MAJOR REPAIR (**RII**) AND M-337SDR SWIA2020021148421Floorbeam · cracked*FS 280 BEAM BL12RH SHEAR BOX "L" ANGLE HAS EVIDENCE OF CRACK IN RADIUS. (C-CHECK) RO 2/07/2020 REMOVAED AND REPLACED SHEAR BOX ANGLE AT BL12 RH OF 280.O BULKHEAD, REF CRJ 700 SRM.SDR SWIA2020021148406Floorbeam · corrodedCORROSION NOTED ON TOP OF FLOORBEAM AT FS280.00 (C-CHECK) RO 2/07/2020 REMOVED AND REPLACED CROSS BEAM TOP CAP COMMON TO LH/RH 280.0 BEAMS, REF CRJ 700 SRM.SDR SWIA2020021148405Floorbeam · corroded*COCKPIT FLOOR PANEL 221ALF AFT SUPPORT ANGLE ON FWD SIDE OF FS 280 BEAM HAS EVIDENCE OF CORROSION ON TOP SIDE. (C-CHECK) RO 2/07/2020 REMOVED AND REPLACED COCKPIT AFT FLOOR SUPPORT ANGLE FOR FLOOR PANEL 221ALF COMMON TO THE 280.0 BEAMS, REF CRJ 700 SRM.