JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022031428116Floorbeam · corrodedFORWARD CARGO PIT AFT BULKHEAD STRUCTURE STA 500D LOWER RAIL ASSY HAS CORROSION RBL 26-30 WL 158 / REMOVED CORROSION. NO ALLOWABLE DAMAGE LIMITS. REMOVED AND REPLACED RAIL ASSY IAW B737 SRM 51-10-02-0G-0 AND 51-40-02-0G-0SDR SWAA2022031428111Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR PANEL STA 727 HORSESHOE SUPPORT HAS CORROSION. / REMOVED FLOOR PANEL SUPPORT AT STA 727 NO LIMITS FOUND REPLACED IAW SRM 51-10-02-00-0 PARA 9.C. RECIVED NEW PART; P/N 453A2611-25; SI #7253171 REPLACE ON SHELF.SDR SWAA2022031409194Floorbeam · corroded***CORROSION*** BS 986 FLOORBEAM HAS CORROSION AT SEVERAL NUTPLATE LOCATIONS LBL 43 - RBL 43; WL 208 / REMOVED CORROSION FROM BS986 FLOOR BEAM IN SEVERAL LOCATIONS LBL43-RBL43 WL208 MOST MATERIAL REMOVED AT RBL43; 2' X 1' X .042' ORIGINAL THICKNESS .150' FOUNDSDR AALA2019082879057Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR SUPPORT BEAM BETWEEN FR 35.1 AND FR 35.3 AT -Y1629. REPLACED FLOOR SUPPORT BEAM PER SRM 51-42-11.SDR FDEA2019081521850Floorbeam · crackedFLOORBEAM AT BS 580, LBL 45.5 WAS CRACKED. COMPLIED WITH EA F-5310-T0348746 P1.SDR SWAA2022031431246Floor Support · crackedPASSENGER CABIN STA 380 TO STA 400 BL 0 FLOOR BOARD SUPPORT IS CRACKED IN TWO LOCATIONS AS MARKED. / REMOVED DAMAGED (CRACKED) FLOOR BOARD SUPPORT FROM STA 380-400 BC O AND INSTALLED NEW FLOOR BOARD SUPPORT P/N 143A5410-170 ATAG# A13203 IAW SRM 51-40-02-0G-0 ASDR R61A201908281873Floorbeam · corrodedWHILE AC WAS IN FOR HVY CK FOUND REAR FUSELAGE FLOOR STRUCTURE AT FR 90 GUSSETS AT RBL 14 AND RBL 32 HAVE CORROSION. MX REMOVED AND REPLACED REAR FUSELAGE FLOOR STRUCTURE AT FR 90 GUSSETS PN 170-60257-001 AT RBL 14 AND RBL 32 IAW SRM 51-41-02. SEE AAR WC# 450SDR AALA2019082759053Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT FLOORBEAM AT BS 500I BETWEEN S25L AND S25R. REPLACED THE FLOORBEAM IAW SRM 541-40-02.SDR SWAA2019081535952Floorbeam · crackedPASSENGER CABIN FLOOR STRUCTURE CRACKED AT BS. 540, BETWEEN BL 0 TO LBL 24. R&R FLOOR STRUCTURE IAW DWG & SRM.SDR JR2R2019081069Floorbeam · corrodedFLOOR BEAM STA 294.5 UPPER CAP CORRODED BETWEEN LBL8 AND BL0.SDR SWAA2022031438229Angle · corrodedAFT CARGO FLOOR AREA FLOOR SUPPORT T-ANGLE AT STA 795 AND RBL 18 SHOWS SOME HOLES WITH CORROSION. 82-114. / REMOVED CORROSION ON AFT CARGO COMP. FLOOR SUPPORT 'T' ANGLE AT STA: 795 AND RBL-18 PER REF B737 SRM 51-10-02-0G-0; AREA WITHIN LIMITS PER REF. B737 SRMSDR AALA201909099067Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT BS 986 AND LBL 17. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4.SDR AALA201909099066Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT BS 986 AND LBL 14. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4.SDR AALA201909099065Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT BS 986 AND RBL 43. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-4.SDR AALA201909049031Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 1016, S17L, LBL 22 TO LBL 25. REPAIRED FLOORBEAM PER T CAP REPAIR EA 297401.SDR CA191021036Fitting · corroded(CAN) LBL 27 FLOOR BEAM END FITTING BLENDED TO REMOVE CORROSION. (TC# 20191021036)SDR REXA2019081381181Floorbeam · crackedCRACKED LONGITUDINAL FLOOR BEAM LBL 12 AND FS 280. BELOW COCKPIT. FLOORBEAM LBL 12 AND FS 280 BELOW COCKPIT WAS REPAIRED PER REO 690-53-11-1159 REV. -- AND REO 690-53-11-431 REV. -ASDR JR2R2019080822183Floorbeam · corrodedDURING ACCESS AND REMOVAL OF STRUCTURE FOR STA 947 FLOOR BEAM REPAIR, FOUND EXTENSIVE CORROSION ON STA 967 BEAM AT APPROXIMATE LBL25.SDR FXGA201908081965Floorbeam · corrodedCORROSION ON RBL 11.5 FLOOR BEAM AT F/STA 240. TO REINFORCE THE LOWER FLANGE OF THE RBL 11.5 FLOOR BEAM AT F/STA 240, AFTER CORROSION REMOVAL. THE CORROSION IS LOCATED ON THE BOTTOM SIDE OF THE LOWER FLANGE. CLEAN CORROSION AND INSTALL LOWER REINFORCING ANGSDR SWIA2019082946242Floorbeam · crackedFS 280.0 CLIPS CRACKED AT RBL9 AND LBL9. REMOVED AND REPLACED L/H AND R/H INBOARD CLIP ANGLES AT LOCATION FS 280.00 LBL 9 AND RBL 9.REF. IAW SRM.SDR REXA2019082871258Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY: ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019080701257Floorbeam · corroded[ IN REFERENCE NRC S/N 144 ] INITIAL INSPECTION: CORROSION ON FLOOR SUPPORT IN STA. FS= 280 BETWEEN STRG 26LH TO 26RH AT MAIN AVIONICS COMPARTMENT. (E/E) [ TASK 900-53-140-300 APPENDIX A ] TCI: 100-09, 100-09E4, 100-09E5
SUMMARY: LEVEL CORROSION 2. FLOOR SUPPSDR REXA2019082871256Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 322 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY:ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR REXA2019082871255Floorbeam · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX)
SUMMARY::ANGLE WAS REPLACED PER CRJ/900 SRM 51-42-06-001-001-A01SDR DALA2019080984684Floorbeam · corrodedCORROSION FLOOR BEAM STA 365 FROM BL 0 TO RBL 30 AT PASSENGER CABIN FLOOR STRUCTURE. AMDS 2020-2427. CPAX. SUMMARY OF NRC 00340 (CORROSION LEVEL 2) FLOOR BEAM STA 365 FROM BL 0 TO RBL 30 AT PASSENGER CABIN FLOOR STRUCTURE WAS REPAIRED PER B757-200 SRM 53-00-51SDR KCSA201908071198Floorbeam · corrodedEVIDENCE OF CORROSION ON UPPER CHORD OF MAIN DECK FLOOR BEAM AT STA 2360 RBL 53SDR SWAA2022031457502Floorbeam · corroded***CORROSION*** B.S. 986.5 FLOOR BEAM; UPPER SURFACE; AT R.B.L. 30-40; W.L. 208.1. / CORROSION ON BS 986. 5 FLOOR BEAM UPPER SURFACE AT RBL 30-40; WL 208.1 WAS REPAIRED IAW ATS ER 19-04365 REV IR DATED 20AUG19 AND EA 1-753-35433 REV IRSDR CA191022027Floorbeam · corroded(CAN) FUSELAGE FLOOR BEAM AT LBL 9.0 FS 477.40 HAS CORROSION DAMAGE ON THE INBOARD FLANGE (TC# 20191022027)SDR FDEA2019080761800Floorbeam · crackedMDCC - FR16 -Y1456, FLOOR SUPPORT CRACKED APPROX 1.5 INCH IN LENGTH REPAIRED THE MAIN DECK CRACKED FLOOR SUPPORT AT FR16 -Y1456 PER SRM 53-12-15 FIG 207. THE REPAIR WAS CATEGORY B AND WAS CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR JR2R2019080624267Floorbeam · corrodedFLOOR BEAM STA 312 UPPER CAP EXISTING REPAIR SPLICE CORRODED BETWEEN LBL 24 AND RBL 24SDR JR2R2019080624264Floorbeam · corrodedFLOOR BEAM STA 344 UPPER CAP EXISTING REPAIR SPLICE CORRODED BETWEEN LBL 15 TO RBL 15SDR SWAA2019090336523Floorbeam · corrodedFLOORBEAM UPPER T CHORD LOCATED CORRODED AT BS. 986, BETWEEN LBL 5 TO RBL 44. REPAIRED FLOORBEAM UPPER CHORD IAW SRM & EA.SDR AALA2019082989062Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR BEAM AT FR 21 AND -Y1292. REPLACED FLOOR BEAM PER SRM 51-42-11.SDR COEA2019080406Floorbeam · corrodedWO 198966 NR 100115 HEAVY CHECK COE/MINOR REPAIR: FLOORBEAM 7 HAS MULTIPLE AREAS OF LEVEL 2 CORROSION. CORRECTIVE ACTION: REPLACED FLOORBEAM WITH OEM.SDR SWAA2019081435883Floorbeam · crackedFLOOR SUPPORT ANGLE CRACKED AT L-1 DOOR CUTOUT FORWARD FRAME FLOOR LEVEL AT BS. 303.9, LBL 57. / R&R FLOOR SUPPORT ANGLE PER SRM AND DWG.SDR ASAA2019080843331Floorbeam · crackedMAIN CABIN, PANEL BREAK SUPPORT CHANNEL CRACKED AT STA 540 BL0-LBL24. GROUNDED - YES. REMOVED AND REPLACED PANEL BREAK AT STA 540 BL 0 - LB L 24 IAW B737-800 SRM 51-40-02 AND BOEING DWG 143A0060 REV-.SDR AALA201909099059Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 64+8, RBL -Y1292. REPLACED FLOORBEAM PER SRM 51-72-11-911-001 AND DRAWING D53472815.SDR AALA201909049044Splice · wornAIRCRAFT IN BASE MAINTENNACE: FLOORBEAM SECTION CONNECTING SPLICE HAS ELONGATED / WORN HOLE AT FR 68 AND -Y1162.5. REPLACED SECTION CONNECTING SPLICE PER SRM 51-72-11.SDR AALA201909049047Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 68, LBL Y765. REPLACED FLOORBEAM PER SRM 51-72-11 AND DRAWING D53472815.SDR AALA201909049058Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM FROM FR 66 TO FR 68, RBL -Y1225. REPLACED FLOORBEAM PER SRM 51-72-11-911-001.SDR AALA201909049055Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM FROM FR 64 TO FR 66, RBL -Y765. REPLACED FLOORBEAM PER SRM 51-72-11-911-001 AND DRAWING #D53472230.SDR AALA201909049053Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 66+5, RBL -Y465. REPLACED FLOORBEAM PER SRM 51-72-11 AND DRAWING D53472816.SDR AALA201909049051Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 68, RBL -Y765. REPLACED FLOORBEAM PER SRM 51-72-11-911-002 AND DRAWING D53472000.SDR REXA201908131182Floorbeam · crackedCRACKED FLOORBEAM RBL 12 AND FS 280. BELOW COCKPIT. FLOORBEAM RBL 12 AND FS 280. BELOW COCKPIT WAS REPAIRED PER CRJ-900 REO 690-53-11-1159 REV--SDR ABXA201908063137Floorbeam · corrodedCORROSION ON THE UPPER CHORD OF THE FORWARD LOWER CARGO COMPARTMENT FLOOR BEAM AT FUSELAGE STATION 478. THE CHORD WAS REPAIRED. THE AIRPLANE WAS GROUNDED.SDR ASAA2019081923407Floorbeam · corrodedAFT CABIN FLOOR SUPPORT CORRODED BS 947, BL 5L - BL 10R. GROUNDED - YES. REMOVED DAMAGE AND CHECKED LIMITS ORIGINAL THICKNESS .180 REMAINING 0.151,REMOVED 0.029. OUT OF LIMITS IAW B737-800 SRM 53-70-51. CUT OUT DAMAGE ANDINSTALLED "T" CHORD REPAIR STA 947 LBL SDR SWAA2019090336526Floorbeam · corrodedUPPER CHORD OF FLOOR BEAM CORRODED AT BS. 986, BETWEEN RBL 40 TO RBL 45. REPAIRED UPPER CHORD PER ER AND EA.SDR AALA2019082759020Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR BEAM AT BS 986 AND LBL 43. REPLACED FLOOR BEAM PER SRM 53-00-51-2R-1 AND EA 296997.SDR CALA2019080431296Floorbeam · damagedCABIN - STA 1087 LBL 23 FLOOR BEAM FOUND FLOOR PANEL HOLE ELONGATED. (REF NR LP 9131027). CABIN STA 1087 LBL 23 FLOOR BEAM UPPER FLANGE REPAIRED AS PER SRM 53-00-51 REPAIR 2 FIG 201.SDR KCSA201908011187Floorbeam · crackedBULK PIT FLOORBEAM CRACKED STA 2000 RBL 32
Back to JASC 5315