What was found
MDCC - FR16 -Y1456, FLOOR SUPPORT CRACKED APPROX 1.5 INCH IN LENGTH REPAIRED THE MAIN DECK CRACKED FLOOR SUPPORT AT FR16 -Y1456 PER SRM 53-12-15 FIG 207. THE REPAIR WAS CATEGORY B AND WAS CLASSIFIED AS MAJOR PER GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MDCC - FR16 -Y1456, FLOOR SUPPORT CRACKED APPROX 1.5 INCH IN LENGTH REPAIRED THE MAIN DECK CRACKED FLOOR SUPPORT AT FR16 -Y1456 PER SRM 53-12-15 FIG 207. THE REPAIR WAS CATEGORY B AND WAS CLASSIFIED AS MAJOR PER GMM 6-2-100.