SDR SWAA2019030130195Floorbeam · corrodedFLOORBEAM UPPER SURFACE CORRODED AT BS 986, BETWEEN LBL 54 TO RBL 54. REPAIRED FLOORBEAM IAW EA & ER.SDR SWAA2019022129878Floorbeam · corrodedFRAME UPPER SURFACE CORRODED AT BS 986.5, BETWEEN LBL 45 TO RBL 45. REPAIRED FLOORBEAM IAW ATS ER AND EA.SDR R61A2019020731153Floorbeam · corrodedDURING HEAVY CHECK MAINTENANCE FOUND LH OUTBOARD FLOOR SUPPORT IS CORRODED AT FR 16. REMOVED AND REPLACED L-H O/B FLOOR SUPPORT
AT FR 16. REF EMB SRM 51-40-08. A/C REMAINS IN CHECK.SDR SWAA2019020429135Floorbeam · crackedFORWARD STABILIZER H DRUM UPPER LT SUPPORT LINK OUTBOARD SUPPORT STRUCTURE CRACKED IN RADIUS AT BS 202, LBL 4.6. REPAIRED FLOORBEAM PER EA.SDR AALA2019013109021Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM AT FRAME 64 AND STRINGER 24L. REPLACED THE FLOORBEAM IAW SRM 51-72-11.SDR SWAA2019020629347Strap · corrodedFLOORBEAM STRAP CORRODED AT BS 1016, RBL 3. REPAIRED STRAP PER EA.SDR AALA201901296003Floorbeam · crackedCRACKED CABIN FLOORBEAM AT BS 540, BETWEEN BL 0 AND LBL 24. REPLACED THE FLOORBEAM IAW RD 51-00-05-1.SDR SWIA2019022145559Floorbeam · corrodedCENTER FS 617.00 BETWEEN RBL9 AND LBL9 CORROSION AT AFT FLOORBEAM SUPPORT TOP CAP UNDER FLOOR PANEL 281DLF. (C-CHECK) RO: 02/20/2019 REMOVED AND REPLACED VENT ASSY AND PACKER PN: 601R35235-61 WITH NEW VENT ASSY AND PACKER AT CENTER FS 617 BETWEEN RBL9 AND LBLSDR DALA2019012200470Floorbeam · corroded(LOG 0913271) DURING INSPECTION FOUND CORROSION FLOOR STRUCTURE BEAM LOCATED AT BS.986 AND RBL32 TO RBL42 AFT GALLEY AREA. PERFORMED PERMANENT REPAIR FLOOR STRUCTURE BEAM LOCATED AT B.S 986 AND RBL 32 TO RBL 42 AT AFT GALLEY AREA ASPER PRI 574151-14 REVISION 0SDR AALA201901232003Floorbeam · corrodedCORROSION ON FORWARD CARGO BAY FLOORBEAM ANGLE AT BS 500I BETWEEN LBL 24 AND RBL 24. REPLACED THE FLOORBEAM ANGLE IAW SRM 51-10-02.SDR REXA2019012100056Floorbeam · corrodedFLOORBEAM FS559+112- FS 589 IS CORRODED LBL27. REPAIRED FLOORBEAM AT LBL27 FS559+112 TO FS589 IAW REO 601R-53-61-6839.SDR DALA2020012800509Floorbeam · corrodedINITIAL INSPECTION. CORROSION ON STRINGER RBL: 2.90, 7.55, 10.45, 16.10 AND LBL: 2.90 STA: 1469 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: IN REF NRC 00147 ( CORROSIN LEVEL II )PREVIOUS REPAIR DOUBLERS AT STGR RBL 2.90, 10.45, AND 16.10 WERE REPLACED PER B75SDR AALA2019012319002Floorbeam · corrodedCORROSION ON THE FLOORBEAM UPPER TEE, BS 947.5, RBL 45.50. REPAIRED THE FLOORBEAM IAW SRM 53-70-51-2R.SDR REXA2019011700061Floorbeam · corrodedFLOORBEAM LBL 27 O/B AND I/B FLOOR LANDINGS HAS CORROSION SPOTS BETWEEN FS 559+112 THRU FS 621, IN THE CARGO BAY BELOW THE FLOOR. REMOVED FLOORBEAM CAP AND INSTALLED NEW FLOORBEAM CAP IAW SRM 51-24-36, 51-42-21 AND 51-42-22 FS559+118 TO FS609. CORROSION FS559+SDR SWAA2019020529181Floorbeam · crackedFLOORBEAM CRACKED AT BS 294, RBL 52. REPAIRED FLOORBEAM IAW EA & ER.SDR DALA2019011600317Floorbeam · corrodedCORROSION FLOORBEAM -Y1162.5 FR68 TO FR69 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y1162.5 FR68 TO FR69 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG #33472780.SDR DALA2019011600315Floorbeam · corrodedCORROSION SPLICE FR68 INBOARD SIDE UPPER POSITION FLOORBEAM +Y1162.5 AT AFT GALLEY AREA. REPLACED SPLICE FR68 INBOARD SIDE UPPER POSITION FLOORBEAM +Y1162.5 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472780.SDR A6WA201946301Floorbeam · corrodedFLOORBEAM CAP CORRODED, FS569.00-621.00, LBL9. REPLACED CAP IAW REO 601R-53-61-3780 REV-A.SDR SWIA2019022145554Floorbeam · corrodedCENTER FS 589.00 + 00 BETWEEN RBL9 AND LBL9 CORROSION AT AFT FLOORBEAM TOP CAP UNDER FLOOR PANEL 281CLF. (C-CHECK) RO: 02/20/2019 REMOVED AND REPLACED FS589 BETWEEN RBL9 AND LBL9 CAP STRIP IAW SRM.SDR YENA201901150035Floorbeam · crackedDURING HEAVY MAINTENANCE, FWD CABIN FLOORBEAM Y254 FRAME 21-22 STR 23L HAD A CRACK (REF N/R 440541-20262); REF N/R 440541-20262 - REMOVED AND REPLACED FWD CABIN FLOORBEAM Y254 FRAME 21-22 STR 23L IAW SRM 51-42-11.SDR YENA201901150034Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM -Y1292 FRAME 69-70 STR 23R; REMOVED AND REPLACED FLOORBEAM -Y1292 IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 20209.SDR YENA201901150033Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON AFT CABIN FLOORBEAM Y1292 FRAME 69-70 STR LT; REMOVED AND REPLACED FLOORBEAM IAW SRM 51-72-11. WORK ACCOMPLISHED ON NR 20230.SDR A6WA2019011846299Floorbeam · corrodedFLOORBEAM CAP CORRODED AT FS569.00 TO 621.00, LBL27. REPLACED CAP IAW SRM 51-42-06, 51-42-21, 51-42-22, REO 601R-53-00-005 REV-B.SDR ASAA2019011428100Floorbeam · corrodedAFT WET AREA FLOOR BEAM 2 EA HOLES AT LBL44, RBL44 ARE CORRODED. GROUNDED - YES. COMPLIED WITH REPAIR INSTRUCTIONS ON ENGINEERING AUTHORIZATION 800-53EA-21192, REV 00.SDR AALA201901299017Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM BETWEEN FR 65 AND FR 67 AT -Y318. REPLACED FLOORBEAM PER SRM 51-72-11.SDR AALA201901154003Floorbeam · corrodedCORROSION FOUND ON THE AFT GALLEY FLOORBEAM, BS 993 BETWEEN RBL 33 AND RBL 46. REPLACED THE FLOORBEAM ANGLE IAW RD 51-00-05.SDR DALA2019011400215Floorbeam · corrodedCORROSION FLOORBEAM -Y765 FR64 TO FR66 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y765 LOC. BTW FR64 TO FR66 AT AFT GALLEY. AREA AS PER SRM 51-72-11 AND DWG 92490174. MEASURES OF CORROSION ARE L=1.822", W= 1.023" D=0.030".SDR R61A201901120134Floorbeam · corrodedWHILE IN HEAVY CHECK - WHILE PERFORMING 2236:170EO-53-14-0003-170EO-53-14-0003 L2 DOOR LOWER BEAM REWORK FOUND CORROSION AROUND FWD AND AFT GIRT BAR FITTINGS. REPLACED L2 LOWER BEAM REF SRM 51-40-02 & 51-40-08SDR VNAA2019011299901Floorbeam · corrodedLBL27 FLOORBEAM IS CORRODED FROM FS578 TO FS609. C/A: REMOVED AND REPLACED BEAM P/N 601R35031-263 IAW CRJ 200 SRM 51-40-06, 51-40-11, 51-42-21, 51-42-06, 51-42-15 AND 51-42-22.SDR A6WA2019011546291Floorbeam · corrodedFS 559+80, RBL9 O/B FLOORBEAM CAP CORRODED. REPLACED BEAM CAP IAW REO 601R-53-00-005 REV-B.SDR AALA201901141004Floorbeam · corrodedCORROSION FOUND ON THE AFT CABIN FLOORBEAM UPPER TEE AT BS 986.5, BETWEEN LBL 51 AND RBL 51. REPAIRED THE FLOORBEAM IAW SRM 53-7051-2R-4.SDR SWAA2022030134691Seat Track · corroded***CORROSION*** SEAT TRACK LBL45.50 BS 500B -5' TO BS 500B -1' WL 208 HAS CORROSION IN 1 PLACE. CORROSION IS MARKED. / SEAT TRACK LBL 45.5 BS 500B-5' TO BS 500B-1' WL 208 TO BE REPLACED ON CUSTOMER CARD # N180107SDR SWIA2019020545504Floorbeam · corrodedLH FLOOR SILL ANGLE CORRODED JUST AFT FS 280. (C-CHECK) RO: 02/04/2019 BLENDED OUT CORROSION ON LH FLOOR SILL ANGLE AFT OF FS280.00 AND COMPLIED WITH ALL STEPS IAW REO.SDR FDEA201901100083Floorbeam · crackedCRACK FORWARD CARGO CEILING LBL 45 STA 580 MAIN CABIN FLOORBEAM "T" CAP ON THE RADIUS. DOT 88-001 REMOVED DAMAGED SECTION OF THE LT BS580 LBL45 "T" CORD. FABRICATED ANGLE AND RADIUS STRAP INSTALLED REPAIR PARTS IAW EA 5310-T0344538 P1. COMPLIED WITH FUSELAGE -SDR DALA2019011100240Strap · crackedSHIP 5652 INITIAL INSPECTION. CRACK FLOORBEAM STABILIZATION STRAP STA 395 AND LBL 24 AT FLOOR STRUCTURE WET AREA. CORRECTIVE ACTION: IN REFERENCE NRC 00321; CRACK STRAP (4" LENGTH) ON STA 395 AND LBL 24 AT FLOOR STRUCTURE WAS REPAIRED PER ER/A 509320-14 REV. OSDR DALA2019011100212Floorbeam · corrodedCORROSION FLOORBEAM -Y1732 FR65 TO FR66 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y1732 FR.65 TO FR.66 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DRAWING D53472750.SDR DALA2019011100211Floorbeam · corrodedCORROSION FLOORBEAM +Y765 AT LEVEL OF FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOC. BTW FR.12 TO FR.24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812. MEASURES OF CORROED AREA L=1.211" W=0.902" D=0.095".SDR DALA2019011100210Floorbeam · corrodedCORROSION FLOORBEAM +Y1292 AT LEVEL OF FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 AT LEVEL OF FR 12 TO FR 24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812. MEASURE OF REWORK ARE L=1.560" W=1.455" D=0.069".SDR DALA2019011100209Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 AT LEVEL OF FR20 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y1292 AT LEVEL OF FR.12 TO FR.24 IN PASSENGER CABIN FWD GALLEY AREA AS PER SRM 51-72-11 AND DRAWING D53112812.SDR DALA2019011000208Floorbeam · corrodedCORROSION FLOORBEAM -Y765 FR66 TO FR70 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y765 LOC BTW FR66 TO FR70 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472093. MEASURES OF CORROSION ARE: L=2.098" W=0.747" D=0.068".SDR AALA201901110003Floorbeam · crackedCABIN FLOORBEAM ANGLE WAS CRACKED, BS 540, LBL 2. REPLACED THE FLOORBEAM ANGLE IAW RD 51-00-05-1, AND DRAWING 143A0060.SDR SWAA2022030262277None · corroded***CORROSION*** CORROSION FLOOR BEAM 3 PLACES BS 968 LBL 28 TO LBL 41 WL 208 (MARKED) / CORROSION ON 986 (BS) LBL 28 TO 41 WL 208 FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1 FIG 103 'C'. DEEPEST OF 3EA .9' X .7' X .112'. REPAIRED DAMAGE AREA IAW ATS ER 19-SDR SWAA2022030262275Floorbeam · corroded***CORROSION*** CORROSION FLOOR BEAM BS 1006 LBL 32 WL 208 / REPAIRED FLOOR BEAM BS 1006 LBL 32 WL 208 PER ATS ER 19-01480 REV IR AND SWA EA 1-753-34223 REV IR.SDR SWAA2019031330616Floorbeam · corrodedFLOORBEAM CORRODED AT BS 986, BETWEEN RBL 48 TO LBL 48. REPAIRED FLOORBEAM IAW ER AND EA.SDR REXA201902190152Floorbeam · crackedCRACK ON FLOOR BEAM [ LOWER/AFT FLANGE ] IN STA. FS= 280 AND 14RBL AT PAX CABIN FWD WET AREA. (CPAX) TCI: 53-10-219 COMPLETE: FLOOR BEAM [ LOWER/AFT FLANGE ] IN STA. FS= 280 AND 14RBL AT PAX CABIN FWD WET AREA WAS REPLACED PER. CRJ-900 SRM 51-42-06-001-001
-SDR DALA2019011000206Floorbeam · corrodedCORROSION FLOORBEAM +Y160 FR68 TO FR70 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y160 FR68 TO FR70 AT AFT GALLEY AREA AND FASTENERS AS PER SRM 51-72-11 AND DWG D53472780.SDR DALA2019011000205Floorbeam · corrodedCORROSION FLOORBEAM -Y1225 FR67 TO FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y1225 FR67 TO FR68 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472780. MEASURE OF CORROSION ARE:L=0.860" W=0.557" D=0.053".SDR DALA2019011000204Floorbeam · corrodedCORROSION FLOORBEAM +Y1162.5 FR68 TO FR69 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1162.5 LOCATED BTW FR68 TO FR 69 AT AFT GALLEY AREA AS PER SRM 51-72-11 AND DWG D53472780.SDR AALA201901119009Floorbeam · corrodedCORROSION FOUND ON THE AFT CABIN WET AREA FLOORBEAM ANGLE, AT FRAME 84, Y330. REPLACED THE FLOORBEAM ANGLE IAW SRM 51-75-16, 51-10-03, 51-41-02, AND 51-53-02.SDR AALA2019011009008Support Angle · corrodedCORROSION FOUND ON THE GALLEY FLOORBEAM ANGLE, BS 992 BETWEEN LBL 33 AND LBL 39. REPLACED THE FLOORBEAM ANGLE IAW RD 51-00-05-1, AND SRM 51-40-02.