What was found
CORROSION FLOORBEAM +Y765 AT LEVEL OF FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOC. BTW FR.12 TO FR.24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812. MEASURES OF CORROED AREA L=1.211" W=0.902" D=0.095".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOORBEAM +Y765 AT LEVEL OF FR16 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOC. BTW FR.12 TO FR.24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812. MEASURES OF CORROED AREA L=1.211" W=0.902" D=0.095".