JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201808170883Floorbeam · corrodedFOUND THE FLOORBEAM, FRAME 19 + 6", LBL 10 CORRODED. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-08, AND ETD 2011-190/02333, REV C.SDR A6WA2018080645959Strap · corrodedFLOORBEAM STRAP AT BS 559 HAD CORROSION BETWEEN RBL 27 AND THE RT FLOOR SUPPORT, IN THE CABIN. REMOVED AND REPLACED THE FLOORBEAM STRAP IAW SRM 51-42-06, 51-40-11, 53-41-43, AND 53-00-00SDR DALA2018080104811Floorbeam · corrodedDURING INSPECTION FOUND CORROSION ON FLOORBEAM STA Y= 986.5 RBL 45 AND LBL 45 AT PAX CABIN. AREA WAS REPAIRED PER SRM 53-70-51 REPAIR 4.SDR DALA2018080304833Floorbeam · corrodedCORROSION FLOORBEAM LOCATED BETWEEN FR66+4INCHES TO FR67+15INCHES -Y1292 AT AFT GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2018080304831Floorbeam · corrodedCORROSION FLOORBEAM LOCATED BETWEEN FR 67+1INCH TO FR69-Y1292 AT AFT GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53472780.SDR SWAA2018082024397Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 772, LBL 7.5. REPAIRED FLOORBEAM IAW EA.SDR SWAA2018082024386Floorbeam · corrodedAFT CARGO BAY FLOORBEAM ASSEMBLY CORRODED AT BS 927, RBL 7.5. R&R FLOORBEAM ASSEMBLY IAW DWG & SRM.SDR SWAA2018082024377Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 772, RBL 2.5. REPAIRED FLOORBEAM IAW EA.SDR SWAA2018082024376Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 772, LBL 2.5. REPAIRED FLOORBEAM IAW EA.SDR SWAA2018082024375Floorbeam · corrodedAFT CARGO BAY FLOORBEAM CORRODED AT BS 727D+5, RBL 7.5. REPAIRED FLOORBEAM IAW EA.SDR SWAA2018082024322Floorbeam · corrodedFORWARD CABIN FLOORBEAM CORRODED AT BS 328, BETWEEN RBL 20 TO RBL 56. R&R TEE CAP PER SRM & EA.SDR SWAA2018082024373Floorbeam · corrodedAFT WET AREA FLOOR BEAM UPPER T-CHORD CORRODED AT BS 986.5, BETWEEN LBL 6 TO RBL 52. R&R TEE CAP PER SRM AND EA.SDR DALA2018080204825Floorbeam · corrodedCORROSION FLOORBEAM +Y1292 LOCATED BETWEEN FR67+1INCH TO FR69 AT AFT GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53472780.SDR AALA201807309002Floorbeam · corrodedAIRCRAFT WAS IN BASE MAINTENANCE. CORROSION FOUND ON FLOORBEAM 3" FORWARD OF FR 35.5, STR 44. REPLACED FLOORBEAM PER SRM 53-21-14-001FIG 00107 SHEET 1 AND SRM 51-42-11.SDR UIEA2018071601480Floorbeam · corrodedMAIN CABIN FLOORBEAM UPPER CHORD STA 654+121 LBL 75 HAS CORROSION. ACCOMPLISHED REPAIR ON MAIN CABIN FLOORBEAM UPPER CHORD STA 654+121 LBL 75 PER EA 767-5340-28-A7334 IR REF NRC A043198.SDR UIEA2018071001422Floorbeam · corrodedMAIN CABIN STA 287 BETWEEN LBL6 AND LBL 20 FLOORBEAM UPPER T-CAP CORRODED. UPON FURTHER INSP FOUND CORROSION ON EXISTING REPAIR DOUBLER. REMOVED FABRICATED AND INSTALLED REPAIR DOUBLER AT STA 287 BETWEEN LBL6 AND LBL20 PER SRM 53-00-51-2R-2 AND SRM 51-40-02-06SDR ASAA2018082165867Floorbeam · corrodedFWD WET AREA BS 312 FLOORBEAM LBL 10 TO 20 HAD CORROSION ON THE UPPER HORIZONTAL FLANGE. ACFT GROUNDED. REPAIRED THE FLOORBEAM IAW EA 800-53EA-20655, AND SRM 53-10-51-2R-12, REPAIR 12.SDR ASAA2018082065827Floorbeam · corrodedFWD WET AREA BS 294, FLOORBEAM, LBL 12 HAS AREA OF CORR ON UPPER FLANGE. ACFT GROUNDED. THE FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1. REPAIRED THE FLOORBEAM IAW EA 800 53EA 20611.SDR ASAA2018081525774Floorbeam · corrodedBS 986 FLOORBEAM HAD AREAS OF CORROSION ON THE UPPER FLANGE. ACFT GROUNDED. THE FLOORBEAM WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1. REPAIRED THE FLOORBEAM IAW SRM 53-70-51.SDR ASAA201808155772Floorbeam · corrodedAFT WET AREA, BS 947 FLOORBEAM UPPER FLANGE, LBL 47-50 HAD AREAS OF CORROSION. ACFT GROUNDED. REPAIRED AND REPLACED THE FLOORBEAM TEE IAW SRM 53-70-51-2R-5.SDR ASAA20180815771Floorbeam · corrodedAFT WET AREA FLOORBEAM, BS 952, LBL 16 TO LBL 24, HAD AN AREA OF CORROSION. ACFT GROUNDED. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-70-51-1A-1, FIG 104, DETAIL C. REMOVED THE FLOORBEAM IAW SRM 51-40-02-0G-0, PARA 7D.6, FABRICATSDR AALA201807279008Floorbeam · corrodedTHE AIRCRAFT IS IN BASE MAINTENANCE. CORROSION FOUND ON FLOORBEAM AT FRAME 58+1.2 , BL 0. REPLACED FLOORBEAM PER SRM 51-42-11.SDR DALA2018072604742Floorbeam · corrodedCORROSION ON FLOORBEAM LOCATED BETWEEN Y1292 RE66+5 TO FR67+15. REPLACED IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2018072604741Floorbeam · corrodedCORROSION ON FLOORBEAM Y254 LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53110984.SDR DALA2018072604740Floorbeam · corrodedCORROSION ON FLOORBEAM Y1292 LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED IAW SRM 51-42-11 ABD DWG D53110920.SDR SWAA2022021604903Floorbeam · corrodedSUPPLEMENTAL INFORMATION: ***CORROSION*** FLOOR BEAM HAS SMALL AREA OF CORROSION AT BS 328; RBL 45; WL 208. / BLENDED OUT CORROSION AT STA 328 RBL 45 WL 208. I-A-W SRM 51-10-02-0G-0. L = 1' W = 1' DEEP = .030 OUT OF LIMITS PER SRM 53-10-51-1A-1. SHOT PEENED ARSDR DALA2018072504738Floorbeam · corrodedCORROSION FLOORBEAM Y2541 LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2018072504737Floorbeam · corrodedCORROSION FLOORBEAM Y1132 LOCATED BETWEEN FR68 TO FR69 AT AFT GALLEY AREA. REPLACED FLOOR BEAM IAW STR 51-72-11 AND DWG D53472780.SDR DALA2018072504736Floorbeam · corrodedCORROSION FLOORBEAM LOCATED BETWEEN FR66+5 INCHES TO FR 70 Y765 AT AFT GALLEY AREA. REPLACED IAW SRM 51-42-11 AND DWG D53472815.SDR DALA2018072504735Floorbeam · corrodedCORROSION ON FLOORBEAM Y1292 LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED FLOORBEAM IAW SRM 51-72-11 AND DWG D53112812.SDR DALA2018072504734Floorbeam · corrodedCORROSION FLOORBEAM LOCATED BETWEEN Y512 FR67+10 TO FR70 AT AFT GALLEY AREA. REPLACED IAW SRM 51-42-11 AND DWG D53472780.SDR AALA20180724001Floorbeam · corrodedTHE AIRCRAFT IS IN BASE MAINTENANCE. FLOORBEAM AT STATION 947 LBL 56.5, UPPER SURFACE OF UPPER/FORWARD FLANGE HAS CORROSION AT THE FORWARD/OUTBOARD CORNER OF THE LAV MOUNT. REPAIRED FLOORBEAM PER SRM 53-70-51-2R-5.SDR V0XD20180725004Floorbeam · crackedLT 280.00 BEAM HAS SIGNS OF CORROSION AND RT 28 BEAM CRACKED. REMOVED AND REPLACE 280 CROSSBEAM IAW SRM 53-11-41, 51-42-21, 51-42-06, 51-42-13, 51-40-11, 53-21-03, 51-21-11, 51-25-16, 51-41-02, AMM 20-70-00 AND NDTM 51-20-006-250.SDR DALA2018072404703Floorbeam · corrodedCORROSION ON FLOORBEAM Y1292 LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53112812.SDR DALA2018072404702Floorbeam · corrodedCORROSION ON FLOORBEAM LOCATED BETWEEN FR67-10 TO FR70, Y1512 AT AFT GALLEY AREA. REPLACED IAW SRM 51-42-11 AND DWG D3472780.SDR DALA2018072404669Floorbeam · corrodedCORROSION ON FLOORBEAM Y765, LOCATED BETWEEN FR12 TO FR24 AT FORWARD GALLEY AREA. REPLACED IAW SRM 51-72-11 AND DWG D53112812.SDR FDEA201807221801Floorbeam · corrodedLT MAIN CABIN STA 377 FLOORBEAM UPPER CHORD HAS AREAS OF CORROSION ON FORWARD FLANGE UPPER AND LOWER SURFACES (EXFOLIATED LOWER AT NUTPLATES). COMPLIED WITH EA NR F-5310-T0341012 P1, FUSELAGE- MAINFRAME CORROSION ON STA 377.7 FLOORBEAM LBL 24.75 - LBL 58.22.SDR DALA2018072204600Floorbeam · corrodedCORROSION FLOORBEAM +Y1292 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y1292 LOC FROM FR 12 TO FR 24 AT FWD GALLEY AREA AS PER SRM 51-72-11SDR FDEA201807201794Floorbeam · corrodedT-CAP AT FR 15 Y-1959 HAS CORROSION. REMOVED CORROSION PER SRM 53-12-15, MATERIAL LOSS AT FASTENER HOLE 100%, BEYOND LIMITS PER SRM 53-12-15. REMOVED AND REPLACED T-CAP, FR12 TO FR17, -Y1959 PER SRM 51-40-20 AND DWG A536-12213.SDR DALA2018072104599Floorbeam · corrodedCORROSION FLOORBEAM -Y765 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y765 BTW FR 12 TO FR 24 FWD GALLEY AREA AS PER SRM 51-72-11; 51-42-11 AND DRAWING D53112812.SDR DALA2018072104598Floorbeam · corrodedCORROSION FLOORBEAM +Y765 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOCATED FROM FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812.SDR DALA2018072104597Floorbeam · corrodedCORROSION FLOORBEAM +Y254 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y254 LOCATED FROM FR2 TO FR24 AT FWD GALLEY.SDR DALA2018072104596Floorbeam · corrodedCORROSION FLOORBEAM +Y1225 LOC BTW FR66 TO FR68 AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1225 BTW FR 66 TO FR 68 AFT GALLEY AREA AS PER SRM 51-72-11,51-42-11 AND DRAWING D53472780.SDR DALA2018072004585Floorbeam · corrodedCORROSION FLOORBEAM -Y81 LOCATED FROM FR 12 TO FR 16 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y81 LOCATED FR 12 TI FR 16 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112882.SDR ASAA2018110896769Floorbeam · corrodedMAIN CABIN AFT WET AREA BELOW FLOOR, FR70 AT Y765 MOUNT HOLE IS GALLED. GROUNDED - YES. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11.SDR AALA20180719005Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CORROSION/CRACK ON FLOORBEAM AT BS 764 BETWEEN LBL 28.5 AND LBL 40. REPAIRED FLOORBEAM PER SRM 53-00-51-2R-1.SDR AALA20180719004Floorbeam · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT BS 764 BETWEEN RBL 27 AND RBL 64. REPAIRED FLOORBEAM PER SRM 53-00-51-2R-1.SDR DALA2018072004584Floorbeam · corrodedCORROSION FLOORBEAM -Y1292 FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM -Y1292 FROM FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53110920.SDR DALA2018072004582Floorbeam · corrodedCORROSION FLOORBEAM - Y1162 LOC BTW FR68 TO FR69+5 INCH AT AFT GALLEY AREA. REPLACED FLOORBEAM -Y1162 LOC BTW FR68 TO FR69+5" AT AFT GALLEY AREA ASPER SRM 51-72-11 AND DWG D53472089.SDR DALA2018072004581Floorbeam · corrodedCORROSION FLOORBEAM +Y1162 LOC BTW F68 TO FR 69+5 INCH AT AFT GALLEY AREA. REPLACED FLOORBEAM +Y1162 BTW FR 68 TO FR 69+5" AFT GALLEY AREA AS PER SRM 51-72-11; 51-42-11 AND DRAWING D534727280.
Back to JASC 5315