What was found
CORROSION FLOORBEAM +Y765 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOCATED FROM FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FLOORBEAM +Y765 LOCATED FROM FR 12 TO FR 24 AT FWD GALLEY AREA. REPLACED FLOORBEAM +Y765 LOCATED FROM FR12 TO FR24 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DWG D53112812.