JASC 5315
Service difficulty reports · 44,218
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2018050201218Floorbeam · corrodedMAIN CABIN FLOORBEAM HAS CORROSION AT STA 328 RBL 25. SPLICED IN NEW SECTION OF FLOORBEAM UPPER CHORD FROM RBL 1 TO RBL 41 PER ECRA 5315-01098.SDR KCSA201805011109Floorbeam · corrodedMAIN DECK FLOORBEAM IS CORRODED AT STA 640 RBL 85.SDR KCSA201805011108Floorbeam · corrodedSTA 980 LBL 89 TO LBL 95 HAS EVIDENCE OF CORROSION.SDR KCSA201805011088Floorbeam · corrodedAFT PIT CEILING STATION 1720 LBL APPROX 10 TO LBL APPROX 115 HAS MULTIPLE AREAS OF POSSIBLE CORROSION ALONG FLOORBEAM.SDR SWIA2018052244697Floorbeam · corrodedBS 349 FLOORBEAM HAS AREAS OF CORROSION BETWEEN RBL 30 AND THE OUTBD END. REPAIRED IAW REO.SDR V0XD20180514006Floorbeam · corrodedBS 280 FLOORBEAM HAD SIGNS OF CORROSION. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-42-06, 51-42-13, 51-42-21, AND 53-11-41.SDR DALA201805012963Floorbeam · corrodedAFT PASSENGER CABIN, FLOORBEAM UPPER FWD FLANGE HAS CORROSION ON UPPER AND LOWER SURFACE AT NUTCLIP BS 1320 LBL 24 - RBL 24. FABRICATED A REPAIR ANGLE AND INSTALLED IAW SRM 53-00-51, TREATED, PRIMED, AND BLENDED AREAS. AREAS WERE WITHIN LIMITS.SDR SWIA2018052244712Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 27 APPROX FS559+85. (C-CHECK) 05/20/2018 REPAIRED FLOORBEAM AT RBL.27 APPROX FS 559.85 IAW SRM.SDR SWIA2018052244711Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 27 FROM FS605 TO FS589. (C-CHECK) 05/20/2018 REMOVED CORROSION FROM FLOORBEAM AT RBL 27 FROM FS589 TO FS605 COMPLIED WITH ALL STEPS OF REPAIR IAW REO.SDR SWIA2018052244710Floorbeam · corrodedCORROSION ON FLOORBEAM AT LBL 9 FS 559+96. (C-CHECK) 05/20/2018 COMPLIED WITH REPAIR IAW SRM.SDR SWIA2018052244709Floorbeam · corrodedCORROSION ON FLOORBEAM AT RBL 9 FS574. (C-CHECK) 05/20/2018 INSTALLED NEW FLOORBEAM AT RBL FROM FS569-FS621 IAW REO AND SRM.SDR V0XD20180514005Floorbeam · crackedFLOORBEAM ANGLE AT RBL 26, BS 280 CRACKED. REMOVED AND REPLACED THE FLOORBEAM ANGLE IAW SRM 51-42-06, 51-42-13, AND 51-25-16.SDR IPXA201804309049Floorbeam · deformedMAIN CABIN FLOORBEAM AT FRAME 48, BETWEEN Y450 AND Y493 FOUND BOWING. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-21.SDR IPXA201804309048Floorbeam · deformedMAIN CABIN FLOORBEAM AT FRAME 49 BETWEEN Y450 AND Y953 FOUND BOWING. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-21.SDR IPXA2018042829047Floorbeam · deformedMAIN CABIN FLOORBEAM AT FRAME 50, BETWEEN Y450 AND Y953 BOWING. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-21.SDR IPXA201804309046Floorbeam · deformedRIGHT MAIN CABIN FLOORBEAM AT FRAME 51 BETWEEN Y450 AND Y953 BOWING. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-21.SDR WVER2018042800001Floorbeam · corrodedBS 280 FLOORBEAM FWD J ANGLE HAS CORROSION AROUND RECEPTACLE AND FASTNERS.SDR COEA2018042524911Floorbeam · corrodedHEAVY CHECK COE/MAJOR REPAIR, LEVEL 2 CORROSION ON FRAME 9 FLOORBEAM AFT LOWER ANGLE OUTBOARD OF LBL 15. REPAIRED PER SRAS ES-2280/18...12908 DATED 5/24/2018.SDR CALA2018043001212Floorbeam · corrodedCABIN FLOORBEAM BS 986, RBL 29 TO RBL 44 CORRODED. REPAIRED THE FLOORBEAM TEE IAW SRM 53-70-51, REPAIR 4, ALTERNATIVE 1.SDR FOTR20180425004Floorbeam · corrodedMAIN CABIN FLOORBEAM BS 967 UPPER FLANGE, UPPER SURFACE FOUND CORRODED 5 SQUARE INHCES, LBL 18, 30, 42, AND 48.SDR DALA2018042502870Floorbeam · corrodedMAIN CABIN FLOORBEAM HAS CORROSION AT BS 377 LBL 3 TO LBL 11. REPAIRED IAW ERA 481634-14MA.SDR A6WA2018042500782Angle · crackedANGLE IS CRACKED ON THE OTBD SIDE OF RBL 9 AND JUST AFT OF THE FLOORBEAM BS 280.SDR COEA2018062027911Floorbeam · corrodedCORROSION FOUND ON FRAME 9, FLOORBEAM, LBL 15, AFT UPPER ANGLE. REPAIRED IAW SRAS ES-2280/18-12908.SDR COEA2018042209911Floorbeam · corrodedHEAVY CHECK COE/MINOR REPAIR, LEVEL 2 CORROSION ON FLOORBEAM 10 STEP UP INTERCOSTAL LBL13-RBL13. REPLACED WITH OEM PART.SDR V0XD20180422006Floorbeam · crackedLEFT SIDE BS 280 FLOORBEAM FOUND CRACKED. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 53-11-41, 51-25-16, 51-21-11, 51-40-11, 51-25-06, 51-42-21, 51-42-13, AMM 20-70-00, AND NDT MANUAL PART 1 51-20-006.SDR FOTR20180421001Floorbeam · corrodedCORROSION AROUND FASTENER HOLES ON THE AFT CARGO BAY FLOORBEAM, FWD ATTACH ANGLE BS 795 BETWEEN STRINGERS 25R AND 26R.SDR IPXA2018042328775Floorbeam · corrodedINSPECTION TYPE: D2, CORRODED FLOORBEAM FITTING BS 1680, LBL 82. INSTALL A NEW FITTING IAW AMM 20-51-01-912-008, REV 92.01.SDR IPXA2018042128773Floorbeam · corrodedINSPECTION TYPE: D2, CORRODED FLOORBEAM FITTING BS 1500, RBL 55. INSTALLED A NEW FITTING IAW AMM 20-51-01-912-008, REV 92.01.SDR IPXA2018042328772Floorbeam · corrodedINSPECTION TYPE: D2, FLOORBEAM UPPER SUPPORT FITTING BS 380, RBL 62- 66. INSTALL A NEW FITTING IAW AMM 20-51-01-912-008, REV 92.SDR AALA2018042509038Floorbeam · distortedTHE FLOORBEAM AT FRAME 30, ABOVE FRAME AND BELOW FLOOR PANEL IS DISTORTED. REPLACED FLOORBEAM IAW DRAWING D53231533000, AND SRM 51-42-11.SDR DALA2018042002720Floorbeam · corrodedAFT MAIN CABIN FLOORBEAM CORRODED AT BS 1681.8, LBL 58.22. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02.SDR AALA20180419010Floorbeam · corrodedFLOORBEAM CORRODED AT BS 951, LBL 17 - LBL 26. INSTALLED SERVICABLE FLOORBEAM ANGLE IAW 51-00-05-1, AND DRAWING 815A0010, AND 141A5676.SDR AALA2018042019009Floorbeam · corrodedCORROSION FOUND ON THE FLOORBEAM, BS 951, BETWEEN LBL 27 AND 48. REPLACED THE FLOORBEAM TEE IAW 51-00-05-1, AND DWG 815A0010.SDR DALA2018042002676Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION OUT OF LIMITS ON FLIGHT DECK FLOOR STRUCTURE OF BS 223, BL 0 - RBL 18, REPAIRED IAW SRM 53-10-51, REPAIR 2.SDR DALA2018042002675Floorbeam · corrodedDURING INSPECTION, FOUND CORROSION OUT OF LIMITS ON THE FLIGHT DECK FLOORBEAM AT BS 217, BL 0 - RBL 18, REPAIRED IAW SRM 53-10-51, REPAIR 2.SDR KCSA201804191078Floorbeam · corrodedMAIN DECK FLOOR STATION 2260 LBL APPROX 30 HAS AREA OF CORROSION ON FLOORBEAM.SDR KCSA201804191077Floorbeam · corrodedMAIN DECK FLOOR STATION 2220 LBL 85 TO RBL 85 MULTIPLE AREAS OF CORROSION ALONG FLOORBEAM.SDR KCSA201804191075Floorbeam · corrodedMAIN DECK FLOORBEAM, BS 2240, LBL 85 TO RBL 85, HAD MULTIPLE AREAS OF CORROSION.SDR KCSA201804191064Floorbeam · corrodedAFT CARGO BAY CEILING, BS 1640, LBL 60 TO LBL 95 HAD CORROSION ALONG THE FLOORBEAM.SDR KCSA201804191065Floorbeam · corrodedAFT CARGO BAY CEILING, BS 1780, LBL 120 - RBL 100 HAD MULTIPLE AREAS OF LIGHT CORROSION ALONG THE FLOORBEAM.SDR KCSA201804191062Floorbeam · corrodedAFT CARGO BAY CEILING, BS 1580, RBL 80 TO RBL 102 HAD MULTIPLE AREAS OF CORROSION ALONG THE FLOORBEAM.SDR KCSA201804191061Floorbeam · corrodedAFT CARGO BAY CEILING, BS 1500, LBL 72 TO LBL 120, HAD MULTIPLE AREAS CORROSION ALONG THE FLOORBEAM.SDR KCSA201804191060Floorbeam · corrodedAFT CARBO BAY CEILING, BS 1500, RBL 72 - RBL 95, APPROXIMATELY, HAS CORROSION ALONG THE FLOORBEAM AT MULTIPLE AREAS.SDR KCSA201804191058Floorbeam · corrodedAFT CARGO CEILING, BS 1540, RBL 36 TO RBL 70 HAS CORROSION ALONG THE FLOORBEAM AT MULTIPLE AREAS.SDR KCSA201804191057Floorbeam · corrodedAFT CARGO BAY CEILING, BS 1500, LBL 40 TO RBL 40 CORRODED AT MULTIPLE AREAS ALONG THE FLOORBEAM.SDR SWIA2018062644829Strap · corrodedLEFT PRESSURE FLOORBEAM STRAP HAD EVIDENCE OF CORROSION, BS 559 BETWEEN LBL 32 TO 43. REMOVED AND REPLACED THE STRAP IAW SRM.SDR YENA201804200181Floorbeam · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOORBEAM, + Y 919, FRAME 66 IN THE AFT GALLEY. REPLACED THE FLOORBEAM IAW SRM 51-72, AND DWGS D53472812.SDR DALA2018041902650Floorbeam · corrodedCORROSION ON THE FLOORBEAM AT Y25, FRAME 66, AFT GALLEY AREA IN PASSENGER CABIN. REPLACED THE FLOORBEAM IAW SRM 51-72-11, DWG D53472800, ISSUE A, AND DWG 10NO1474.SDR SWIA2018062644826Floorbeam · corrodedFLOORBEAM, BS 349 NEAR SERVICE DOOR SILL WAS CORRODED. REMOVED COROSSION AND COMPLIED WITH ALL STEPS OF SRM AND REO.SDR AALA20180418013Angle · corrodedAFT CARGO AFT BULKHEAD FLOORBEAM ANGLE CORRODED AT BS 947.5 BETWEEN RBL 18 TO LBL 13. INSTALLED A NEW FLOORBEAM ANGLE ASSEMBLY IAW SRM 51-40-02-0G.
Back to JASC 5315